Presentación gama ETI / ETI range overview

Anuncio
ETI: FUSIBLES Y APARAMENTA MODULAR / ETI: FUSE-LINKS AND MODULAR SWITCHGEAR
Presentación gama ETI / ETI range overview
FUSIBLES
FUSE-LINKS
• FUSIBLES CILÍNDRICOS
CYLINDRICAL FUSE-LINKS
• CH 8: 2-25 A, 400V
• CH 10: 0,5-32 A, 400 / 500V
• CH 14: 2-50 A, 400 / 500 / 690 V
• CH 22: 16-100 A, 500 / 690 V
BASES PORTAFUSIBLES
FUSE DISCONNECTORS
• BASES PORTAFUSIBLES PARA FUSIBLES CILÍNDRICOS
FUSE DISCONNECTORS FOR CYLINDRICAL FUSE-LINKS
• PCF
- PCF 8: 20 A, 400 V
- PCF 10: 32 A, 690 V
- PCF CC: 30 A, 600 V
• VLC
● • FUSIBLES DIAZED
DIAZED FUSE-lLINKS
• DI para base portafusibles E16: 2-25 A
- VLC 8: 20 A, 400 V
- VLC 10: 32 A, 690 V
- VLC CC: 30 A, 600 V
- VLC 14: 50 A, 690 V
- VLC 22: 100 A, 690 V
DI for fuse base E 16 : 2-25 A
DII para base portafusibles E 27: 2-25 A
DII for fuse base E 27: 2-25 A
• DIII para base portafusibles E 33: 32- 63 A
DIII for fuse base E 33: 32- 63 A
• DIII AC 690V, DC 600V: 2-63 A
• DIII 750V gF: 2-63 A
• DIII AC 1200V 3-channel gF: 2-35 A
• BASES PORTAFUSIBLES PARA FUSIBLES DIAZED
FUSE BASES FOR DIAZED FUSE-LINKS
• Bases unipolares: 25-63 A
1-pole fuse bases: 25-63 A
• Bases tripolares: 25-63 A
3-pole fuse bases: 23-63 A
• DIV para base portafusibles R1 1/4”: 80-100 A
DIV for fuse base R1 1/4”: 80-100 A
• DV para base portafusibles R 2”: 125-200 A
DV for fuse base R 2”: 125-200 A
• BASES PORTAFUSIBLES PARA FUSIBLES NEOZED
FUSE BASES FOR NEOZED FUSE-LINKS
• Bases unipolares
1-pole fuse bases
● • FUSIBLES NEOZED
NEOZED FUSE-LINKS
• D01 para base portafusibles E 14: 2-16 A
D01 for fuse base E 14: 2-16 A
• D02 para base portafusibles E 18: 20-63 A
D02 for fuse base E 18: 20-63 A
• D03 para base portafusibles M 30 x 2: 80-100 A
D03 for fuse base M 30 x 2: 80-100 A
4
- Cuerpo cerámico: 16-63 A
Ceramic fuse base: 16-63 A
- Cuerpo plástico: 16 A
Plastic fuse base: 16 A
• Bases tripolares
3-pole fuse bases
- Cuerpo cerámico: 16-63 A
Ceramic fuse base: 16-63 A
- Cuerpo plástico: 63 A
Plastic fuse base: 63 A
ETI: FUSIBLES Y APARAMENTA MODULAR / ETI: FUSE-LINKS AND MODULAR SWITCHGEAR
DESCARGADORES
SURGE ARRESTERS
INTERRUPTORES
SWITCHES
• INTERRUPTORES MAGNETOTÉRMICOS INDUSTRIALES
• DESCARGADORES DE EXTERIOR
SURGE ARRESTERS FOR OUTDOOR MOUNTING
MINIATURE CIRCUIT BREAKERS
• ETIMAT 11 (0,5-63 A): Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C,D,K
• ETIMAT 11-QC: Intensidad asignada / Rated current: 0,5 - 20A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C,D,K
• ETITEC Grupo A / ETITEC Group A
• DESCARGADORES DE INTERIOR
• ETIMAT 11-RC (Control Remoto / Remote Control):
Intensidad asignada / Rated current: 6 -63A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C
• ETIMAT 11-DC: Intensidad asignada / Rated current: 6 -63A
Poder de corte / Rated short-circuit capacity: 6 kA
Curva / Tripping characteristic: B,C
• ETIMAT 11 (80-125 A): Poder de corte / Rated short-circuit capacity: 15,20 kA
Curva / Tripping characteristic: C, D
• OTROS INTERRUPTORES MAGNETOTÉRMICOS INDUSTRIALES
OTHER TYPES OF MINIATURE CIRCUIT BREAKERS
• ETIMAT 6: Intensidad nominal / Rated current: 6 -63A
Poder de corte / Rated short-circuit capacity: 6 kA
Curva / Tripping characteristic: B,C
• ETIMAT 1N: Intensidad nominal / Rated current: 6 -32A
Poder de corte / Rated short-circuit capacity: 6 kA
Curva / Tripping characteristic: B,C
• INTERRUPTORES DIFERENCIALES EFI
SURGE ARRESTERS FOR INDOOR MOUNTING
• ETITEC Grupo B / ETITEC Group B
• ETITEC Grupo B-F / ETITEC Group B-F
• ETITEC Grupo WENT / ETITEC Group WENT
• ETITEC Grupo C / ETITEC Group C
• ETITEC Grupo D / ETITEC Group D
• Protección de sobretensiones para líneas
de señalización y control
Surge Protection of SIGNAL / CONTROL lines
• Protección de sobretensiones para líneas
de transmisión coaxial
Surge protection in COAXIAL transmission
• ETITEC B-PV
• ETITEC C-PV
RESIDUAL CURRENT CIRCUIT BREAKERS EFI
• EFI 2: 16-80A
• EFI 2 UT: 25A
• EFI 4: 16-80A
• EFI 4 UT: 25-63A
• EFI 4 S: 40-63A
• EFI 4 KV / G: 40A
• INTERRUPTORES DIFERENCIALES CON PROTECCIÓN CONTRA CORTOCIRCUITOS
RESIDUAL CURRENT CIRCUIT BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION
• KZS-1M: Intensidad nominal / Rated current: 6-32A
Poder de corte / Rated short-circuit capacity: 6 kA
Curva / Tripping characteristic: B,C
Corriente de fuga nominal / Rated residual current: 0,03 A
• KZS-2M: Intensidad nominal / Rated current: 6-40A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C
Corriente de fuga nominal / Rated residual current: 0,01-0,03-0,3 A
• KZS-2M UT: Intensidad nominal / Rated current: 16A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C
Corriente de fuga nominal / Rated residual current: 0,01-0,03-0,3 A
• KZS-3M: Intensidad nominal / Rated current: 6 -25A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C
Corriente de fuga nominal / Rated residual current: 0,03 A
• KZS-4M: Intensidad nominal / Rated current: 6-32A
Poder de corte / Rated short-circuit capacity: 10 kA
Curva / Tripping characteristic: B,C
Corriente de fuga nominal / Rated residual current: 0,03 A
5