ETI: FUSIBLES Y APARAMENTA MODULAR / ETI: FUSE-LINKS AND MODULAR SWITCHGEAR Presentación gama ETI / ETI range overview FUSIBLES FUSE-LINKS • FUSIBLES CILÍNDRICOS CYLINDRICAL FUSE-LINKS • CH 8: 2-25 A, 400V • CH 10: 0,5-32 A, 400 / 500V • CH 14: 2-50 A, 400 / 500 / 690 V • CH 22: 16-100 A, 500 / 690 V BASES PORTAFUSIBLES FUSE DISCONNECTORS • BASES PORTAFUSIBLES PARA FUSIBLES CILÍNDRICOS FUSE DISCONNECTORS FOR CYLINDRICAL FUSE-LINKS • PCF - PCF 8: 20 A, 400 V - PCF 10: 32 A, 690 V - PCF CC: 30 A, 600 V • VLC ● • FUSIBLES DIAZED DIAZED FUSE-lLINKS • DI para base portafusibles E16: 2-25 A - VLC 8: 20 A, 400 V - VLC 10: 32 A, 690 V - VLC CC: 30 A, 600 V - VLC 14: 50 A, 690 V - VLC 22: 100 A, 690 V DI for fuse base E 16 : 2-25 A DII para base portafusibles E 27: 2-25 A DII for fuse base E 27: 2-25 A • DIII para base portafusibles E 33: 32- 63 A DIII for fuse base E 33: 32- 63 A • DIII AC 690V, DC 600V: 2-63 A • DIII 750V gF: 2-63 A • DIII AC 1200V 3-channel gF: 2-35 A • BASES PORTAFUSIBLES PARA FUSIBLES DIAZED FUSE BASES FOR DIAZED FUSE-LINKS • Bases unipolares: 25-63 A 1-pole fuse bases: 25-63 A • Bases tripolares: 25-63 A 3-pole fuse bases: 23-63 A • DIV para base portafusibles R1 1/4”: 80-100 A DIV for fuse base R1 1/4”: 80-100 A • DV para base portafusibles R 2”: 125-200 A DV for fuse base R 2”: 125-200 A • BASES PORTAFUSIBLES PARA FUSIBLES NEOZED FUSE BASES FOR NEOZED FUSE-LINKS • Bases unipolares 1-pole fuse bases ● • FUSIBLES NEOZED NEOZED FUSE-LINKS • D01 para base portafusibles E 14: 2-16 A D01 for fuse base E 14: 2-16 A • D02 para base portafusibles E 18: 20-63 A D02 for fuse base E 18: 20-63 A • D03 para base portafusibles M 30 x 2: 80-100 A D03 for fuse base M 30 x 2: 80-100 A 4 - Cuerpo cerámico: 16-63 A Ceramic fuse base: 16-63 A - Cuerpo plástico: 16 A Plastic fuse base: 16 A • Bases tripolares 3-pole fuse bases - Cuerpo cerámico: 16-63 A Ceramic fuse base: 16-63 A - Cuerpo plástico: 63 A Plastic fuse base: 63 A ETI: FUSIBLES Y APARAMENTA MODULAR / ETI: FUSE-LINKS AND MODULAR SWITCHGEAR DESCARGADORES SURGE ARRESTERS INTERRUPTORES SWITCHES • INTERRUPTORES MAGNETOTÉRMICOS INDUSTRIALES • DESCARGADORES DE EXTERIOR SURGE ARRESTERS FOR OUTDOOR MOUNTING MINIATURE CIRCUIT BREAKERS • ETIMAT 11 (0,5-63 A): Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C,D,K • ETIMAT 11-QC: Intensidad asignada / Rated current: 0,5 - 20A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C,D,K • ETITEC Grupo A / ETITEC Group A • DESCARGADORES DE INTERIOR • ETIMAT 11-RC (Control Remoto / Remote Control): Intensidad asignada / Rated current: 6 -63A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C • ETIMAT 11-DC: Intensidad asignada / Rated current: 6 -63A Poder de corte / Rated short-circuit capacity: 6 kA Curva / Tripping characteristic: B,C • ETIMAT 11 (80-125 A): Poder de corte / Rated short-circuit capacity: 15,20 kA Curva / Tripping characteristic: C, D • OTROS INTERRUPTORES MAGNETOTÉRMICOS INDUSTRIALES OTHER TYPES OF MINIATURE CIRCUIT BREAKERS • ETIMAT 6: Intensidad nominal / Rated current: 6 -63A Poder de corte / Rated short-circuit capacity: 6 kA Curva / Tripping characteristic: B,C • ETIMAT 1N: Intensidad nominal / Rated current: 6 -32A Poder de corte / Rated short-circuit capacity: 6 kA Curva / Tripping characteristic: B,C • INTERRUPTORES DIFERENCIALES EFI SURGE ARRESTERS FOR INDOOR MOUNTING • ETITEC Grupo B / ETITEC Group B • ETITEC Grupo B-F / ETITEC Group B-F • ETITEC Grupo WENT / ETITEC Group WENT • ETITEC Grupo C / ETITEC Group C • ETITEC Grupo D / ETITEC Group D • Protección de sobretensiones para líneas de señalización y control Surge Protection of SIGNAL / CONTROL lines • Protección de sobretensiones para líneas de transmisión coaxial Surge protection in COAXIAL transmission • ETITEC B-PV • ETITEC C-PV RESIDUAL CURRENT CIRCUIT BREAKERS EFI • EFI 2: 16-80A • EFI 2 UT: 25A • EFI 4: 16-80A • EFI 4 UT: 25-63A • EFI 4 S: 40-63A • EFI 4 KV / G: 40A • INTERRUPTORES DIFERENCIALES CON PROTECCIÓN CONTRA CORTOCIRCUITOS RESIDUAL CURRENT CIRCUIT BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION • KZS-1M: Intensidad nominal / Rated current: 6-32A Poder de corte / Rated short-circuit capacity: 6 kA Curva / Tripping characteristic: B,C Corriente de fuga nominal / Rated residual current: 0,03 A • KZS-2M: Intensidad nominal / Rated current: 6-40A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C Corriente de fuga nominal / Rated residual current: 0,01-0,03-0,3 A • KZS-2M UT: Intensidad nominal / Rated current: 16A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C Corriente de fuga nominal / Rated residual current: 0,01-0,03-0,3 A • KZS-3M: Intensidad nominal / Rated current: 6 -25A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C Corriente de fuga nominal / Rated residual current: 0,03 A • KZS-4M: Intensidad nominal / Rated current: 6-32A Poder de corte / Rated short-circuit capacity: 10 kA Curva / Tripping characteristic: B,C Corriente de fuga nominal / Rated residual current: 0,03 A 5