PO Box 9123 Wichita, KS 67277 PIPELINE SAFETY IN YOUR COMMUNITY LA SEGURIDAD DE LOS GASODUCTOS EN SU COMUNIDAD Use your senses to stay alert to potential dangers. Use sus sentidos para estar alerta a posibles peligros. LOOK. Blowing dirt, persistent bubbling in standing water and dead vegetation are signs of a possible leak around the pipeline area. A message for you about NATURAL GAS PIPELINE SAFETY MIRE. El polvo que vuela, el borboteo persistente en aguas estancadas y la vegetación muerta son signos de una posible fuga alrededor del área del gasoducto. To our Excavation Partners LISTEN. Un mensaje sobre la seguridad de los Listen for any unusual noises coming from the pipeline. A leak can make a hissing or a roaring sound, depending on the magnitude of the leak. GASODUCTOS DE GAS NATURAL ESCUCHE. Para nuestros socios de excavación Escuche cualquier ruido inusual proveniente del gasoducto. Una fuga puede emitir un sonido sibilante o estruendoso, según la magnitud de la fuga. WHAT TO DO IF YOU SUSPECT A NATURAL GAS LEAK QUÉ HACER SI TIENE SOSPECHAS SOBRE UNA FUGA DE GAS NATURAL SMELL. Detecting an unusual odor could be an indication of a pipeline leak. A natural gas leak will be accompanied by a “rotten egg” odor. 1. Turn off and abandon equipment. Apague y abandone los equipos. 2. Leave the area quickly. Aléjese del área rápidamente. 3. Warn others. Call at least two full working days before you dig. Advierta a otros. 4. Seek the aid of local authorities. Solicite la ayuda de las autoridades locales. Conozca qué hay debajo, llame antes de cavar. 5. Notify the pipeline operator immediately. Llame con una anticipación de dos días hábiles completos. Notifique al operador del gasoducto de inmediato. HUELA. La detección de un olor inusual podría indicar una fuga en el gasoducto. Una fuga de gas natural estará acompañada de un olor a “huevo putrefacto.” IMPORTANT INFORMATION ABOUT NATURAL GAS PIPELINE SAFETY INFORMACIÓN IMPORTANTE SOBRE LA SEGURIDAD DE LOS GASODUCTOS DE GAS NATURAL Texas Gas Service is committed to constructing and maintaining a natural gas pipeline delivery system that complies with applicable state and federal guidelines, industry standards and safety regulations. We apply approved pipeline integrity management techniques to monitor system performance and ensure system reliability. Your knowledge and understanding of underground pipeline facilities, damage prevention and emergency notification is an important element in ensuring pipeline integrity and enhancing system performance. Our goal is to deliver clean, safe and reliable natural gas to the communities we serve. Texas Gas Service tiene el compromiso de construir y mantener un sistema de distribución de gasoductos de gas natural que cumpla con todas las pautas federales y estatales vigentes, los estándares de la industria y las normativas de seguridad. Aplicamos técnicas de administración de la integridad del gasoducto aprobadas para monitorear el sistema y garantizar su confiabilidad. Su conocimiento y comprensión de las instalaciones de gasoductos subterráneas, la prevención de daños y la notificación de emergencias son elementos importantes para asegurar la integridad del gasoducto y mejorar el rendimiento del sistema. Nuestro objetivo es distribuir gas natural limpio y confiable en todas las comunidades a las que prestamos servicios. Look For These Signs Since pipelines are buried underground, line markers like the ones shown below, are used to indicate the presence of a pipeline. These pipeline markers can be found along a street, highway, railway or pipeline right of way and anywhere a pipeline intersects with a street, highway or railway system. Pipeline markers display the material transported in the line, the name of the pipeline operator and a telephone number where the operator can be reached in the event of an emergency. The Importance of Pipeline Markers Pipeline markers are used as warning signs to indicate the presence of a pipeline. Pipeline markers do not indicate the exact location of a pipeline, and the pipeline path may vary between markers. Pipeline markers are helpful in locating pipelines; however, operators must rely on special equipment and service records to determine the location, depth and number of pipelines installed underground. Pipeline Contents and Precautions: • Pipelines are used to deliver gaseous and liquid products. • These products may be colorless and odorless. • Use caution, pipeline leaks may be dangerous. • Contents may be toxic and flammable. Texas Gas Service Responds to Natural Gas Emergencies In the event of a natural gas-related emergency, Texas Gas Service will dispatch emergency personnel immediately. To report a natural gas emergency, call: 911 or 1-800-959-5325 (LEAK) Emergency dispatch personnel are on duty 24 hours/day, seven days/week. As a precaution, public safety personnel, citizens and others unfamiliar with a transmission or distribution pipeline should not attempt to operate any valves, meters, regulators or any other pipeline equipment. Improper operation of this equipment may cause accidents to occur. If you observe unusual activity near the pipeline including suspicious excavation, abandoned vehicles, non-company personnel or non-company vehicles, call 911 immediately. If you observe freshly disturbed soil or perimeter abnormalities, please call Texas Gas Service’s natural gas emergency line at 1-800-959-5325 (LEAK). Texas Gas Service Partners With Public Safety Officials In partnership with public safety officials, we apply basic safeguards to ensure the safety and welfare of the community. Public officials should use the following guidelines: • In the event of a pipeline leak, secure the perimeter area around the leak or hazard and maintain a safe distance. The perimeter area may require the evacuation of people from homes, businesses, schools and other facilities, as well as placing barricades to control traffic and allow emergency access. • To prevent an ignition, please follow these simple precautions: reroute traffic, prohibit smoking and cell phone use, and shut off the electricity to any nearby or adjacent facilities. • If the pipeline leak is burning, attempt to prevent the fire from spreading, but do not try to extinguish the fire. Burning natural gas will not explode. • In the event of an emergency, contact the pipeline company as quickly as possible. Pipeline markers show the pipeline company’s name, emergency telephone number and pipeline contents. Call Before You Dig If you are planning to dig or perform excavation work, we need your help in preventing damage to underground facilities. Before you dig, excavate, plant a tree, till a garden or set fence posts, state law requires calling 811 two full working days prior to the planned excavation start date. Texas Gas Service will mark the location of our natural gas facilities at no charge to you. Records show that damage from excavation-related activities, particularly from equipment digging into pipelines, is the number one cause of pipeline accidents. If You Disturb or Damage a Pipeline In the event you cause any type of damage to a pipeline, please notify the pipeline company immediately. The pipeline owner will inspect and make repairs to the pipeline to maintain its integrity. Damage to the pipeline coating caused by scrapes, dents or dings may lead to a future leak or major incident if not repaired. For natural gas emergencies, call toll-free: Texas Gas Service Emergency Line 1-800-959-5325 (LEAK) Working Within the Transmission Right of Way Our transmission pipelines are built and maintained within rights of way, known as easements. Before you begin any project to modify the existing grade, build a structure, plant trees, fences or terraces, please contact Texas Gas Service to have your work reviewed and approved. The integrity of our pipeline and the safety of your neighbors could be at risk if changes to the easement are made without proper coordination of the proposed work. Encroachments upon rights of way inhibit Texas Gas Service’s ability to respond to potential emergencies, prevent third-party damage, conduct surveillance and perform routine maintenance and required federal and state inspections. Pipeline Integrity Management Texas Gas Service is committed to operating a safe and reliable natural gas pipeline system. Our primary goal is to deliver natural gas safely without causing any harm or danger to customers, communities, employees or the environment. The company’s Pipeline Integrity Management Program meets the requirements identified in CFR 49 192 to implement the “Pipeline Safety Improvement Act of 2002.” Specific practices, processes and procedures have been established to enable the management and execution of the Integrity Management Program. The goals of the Pipeline Integrity Management regulation include: • Provide assurance to the public on pipeline safety. • Accelerate integrity assessment of transmission pipelines in High Consequence Areas (HCAs). • Improve integrity management systems within companies. • Improve the government’s role in validating integrity management. Requirements of the regulation: • Identify HCAs on Texas Gas Service’s transmission system. • Develop the Integrity Management Plan. • Complete baseline assessment of all HCAs by December 17, 2012. To obtain an overview of the transmission integrity management program, visit www.TexasGasService.com, click on the "Safety" tab, and select "Pipeline Integrity." For more information about pipeline safety regulations and operators, please visit www.npms.phmsa.dot.gov or www.phmsa.dot.gov/regulations. For more information about Texas Gas Service, please visit www.TexasGasService.com or call 1-800-700-2443. Identifique estas señales Dado que los gasoductos están enterrados bajo tierra, se usan marcadores de líneas, como los que se muestran a continuación, para indicar la presencia de un gasoducto. Estos marcadores de gasoductos pueden encontrarse en la calle, la carretera, las vías ferroviarias o el derecho de paso del gasoducto y en cualquier parte donde un gasoducto se cruce con una calle, una carretera o un sistema ferroviario. Los marcadores de gasoductos muestran el material transportado en la línea, el nombre del operador del gasoducto y un número de teléfono donde se puede contactar al operador en caso de emergencia. La importancia de los marcadores de gasoductos Los marcadores de gasoductos se usan como signos de advertencia para indicar la presencia de un gasoducto. Estos marcadores no indican la ubicación exacta de un gasoducto y el recorrido del gasoducto puede variar entre los marcadores. Los marcadores de gasoductos son útiles para ubicar los gasoductos, pero son limitados en cuanto a la información proporcionada; sin embargo, los operadores utilizan equipos especiales y registros de servicio para determinar la ubicación, la profundidad y el número de gasoductos instalados bajo tierra. Contenido y precauciones de los gasoductos: • Los gasoductos se utilizan para distribuir productos líquidos y gaseosos. • Estos productos pueden ser incoloros e inodoros. • Tenga cuidado ya que las fugas de gasoductos pueden ser peligrosas. • Los contenidos pueden ser tóxicos e inflamables. Texas Gas Service responde a las emergencias de gas natural En caso de una emergencia relacionada con el gas natural, Texas Gas Service enviará personal de emergencia de inmediato. Para informar una emergencia relacionada con el gas natural, llame al: 911 o 1-800-959-5325 (LEAK) El personal de emergencia está de guardia las 24 horas del día, los 7 días de la semana. Como precaución, el personal de seguridad pública, los ciudadanos y otras personas no familiarizadas con un gasoducto de transmisión o distribución no deben intentar operar ninguna válvula, medidor, regulador ni ningún otro equipo del gasoducto. La operación inadecuada de este equipo puede causar accidentes. Si observa alguna actividad inusual cerca del gasoducto, incluidas excavaciones sospechosas, vehículos abandonados, personal o vehículos no pertenecientes a la empresa, llame al 911 de inmediato. Si observa suelo receintemente perturbado o anormalidades de perímetro, llame a la línea de emergencias de gas natural de Texas Gas Service al 1-800-959-5325 (LEAK). Texas Gas Service trabaja en colaboración con las autoridades de seguridad pública En un trabajo conjunto con las autoridades de seguridad pública, aplicamos medidas de protección básicas para garantizar la seguridad y el bienestar de la comunidad. Las autoridades públicas deben emplear las siguientes pautas: • En caso de una fuga en un gasoducto, asegurar el área perimetral alrededor de la fuga o peligro y mantener una distancia segura. El área perimetral puede requerir la evacuación de personas de sus viviendas, empresas, escuelas y otras instalaciones, además de la colocación de barricadas para controlar el tráfico y permitir el acceso de emergencia. • Para prevenir un incendio, se deben seguir estas precauciones simples: desviar el tráfico, prohibir fumar y cortar la electricidad en cualquier instalación cercana o adyacente. • Si la fuga del gasoducto se está incendiando, intente impedir que el fuego se propague, pero no intente apagar el incendio. El gas natural que se incendia no explota. • En caso de una emergencia, comuníquese con la empresa del gasoducto lo antes posible. Los marcadores de gasoductos muestran el nombre de la empresa del gasoducto, el número de teléfono de emergencia y el contenido del gasoducto. Llame antes de cavar Si está planeando cavar o realizar tareas de excavación, necesitamos que nos ayude a evitar daños a las instalaciones subterráneas. Antes de cavar, excavar, plantar un árbol, labrar un jardín o colocar cercas, la ley estatal exige que llame al 811 dos días laborales antes de la fecha de inicio de su trabajo de excavación. Texas Gas Service marcará la ubicación de sus instalaciones de gas natural sin cargo. Los registros indican que los daños provocados a partir de actividades relacionadas con la excavación, especialmente con equipos que se topan con las tuberías, es la causa principal de accidentes en los gasoductos. Si altera o daña un gasoducto Si llegara a ocasionar algún tipo de daño menor a un gasoducto, notifique a la empresa del gasoducto de inmediato. El propietario del gasoducto inspeccionará y hará reparaciones en el gasoducto para mantener su integridad. Los daños al revestimiento del gasoducto causados por raspones, hendiduras o golpes pueden conducir a una fuga futura o un incidente grave si no se reparan. Para emergencias de gas natural, llame sin cargo: Línea de emergencias de gas de Texas Gas Service 1-800-959-5325 (LEAK) Trabajo dentro del derecho de paso de transmisión Nuestros gasoductos de transmisión están construidos y mantenidos dentro de derechos de paso, conocidos como servidumbre. Antes de comenzar cualquier proyecto para modificar el nivel existente, construir una estructura, plantar árboles, cercos o bancales, comuníquese con Texas Gas Service para que se revise y apruebe su trabajo. La integridad de su gasoducto y la seguridad de sus vecinos podrían estar en riesgo si se realizan cambios en la servidumbre sin la coordinación adecuada del trabajo propuesto. Los abusos de derechos de paso inhiben la posibilidad de Texas Gas Service de responder a posibles emergencias, prevenir daños a terceros, conducir la vigilancia y realizar tareas de mantenimiento de rutina y las inspecciones estatales y federales requeridas. Administración de la integridad del gasoducto Texas Gas Service tiene el compromiso de operar un sistema de gasoducto de gas natural seguro y confiable. Nuestro objetivo principal es distribuir gas natural de manera segura sin causar daños ni poner en peligro a clientes, comunidades, empleados o el medio ambiente. El programa de administración de la integridad del gasoducto de la empresa cumple con los requisitos identificados en CFR 49 192 para implementar la "Ley de mejoras para la seguridad de los gasoductos de 2002". Se han establecido prácticas, procesos y procedimientos específicos para permitir la administración y ejecución del programa de administración de la integridad. Los objetivos de la normativa de administración de la integridad del gasoducto incluyen: • Ofrecer seguridad al público respecto de la seguridad del gasoducto. • Acelerar la evaluación de integridad de los gasoductos de transmisión en áreas de alta consecuencia. • Mejorar los sistemas de administración de la integridad dentro de las empresas. • Mejorar la función del gobierno en la validación de la administración de la integridad. Requisitos de la normativa: • Identificar las áreas de alta consecuencia en el sistema de transmisión de Texas Gas Service. • Desarrollar el plan de administración de la integridad. • Completar evaluaciones mínimas de todas las áreas de alta consecuencia antes del 17 de diciembre del 2012. Para obtener una descripción general de la transmisión del programa de administración de la integridad, visite www.texasgasservice.com, haga clic en Safety (Seguridad) y luego en Pipeline Integrity (Integridad del gasoducto). Para obtener más información sobre normativas de seguridad de gasoductos y operadores, visite www.npms.phmsa.dot.gov o www.phmsa.dot.gov/regulations. Para obtener más información sobre Texas Gas Service, visite www.TexasGasService.com o llame al 1-800-959-5325 (LEAK).