DE INTERRUPTORES CARACTERÍSTICAS GENERALES CARACTERÍSTICAS GERAIS GENERAL CHARACTERISTICS LINEA LINHA DE DISJUNTORES CIRCUIT-BREAKER LINE INSTRUCCIONES DE MONTAJE INSTRUÇÕES DE MONTAGEM ASSEMBLY INSTRUCTIONS DWA630...800 POSICIONES DE LA PALANCA DE MANIOBRA POSIÇÕES DA ALAVANCA DE MANOBRA POSITIONS OF THE OPERATING LEVER DISTANCIAS MINIMAS DESDE LAS PAREDES DISTÂNCIAS MÍNIMAS ATÉ AS PAREDES EXTERNAS DISTANCIA MINIMA ENTRE PANEL Y FRENTE DISTÂNCIA MÍNIMA ENTRE A CHAPA DE MONTAGEM E A PORTA DO PAINEL MINIMUN DISTANCES FROM THE WALLS MINIMUN DISTANCES BETWEEN PANEL AND FRONT "I" 100 (4POL.) 280,0 (3-2 POL.) 210,0 108.0 Iu = 800 A Ue = 690 V T = 45 ºC CAT. A 30 DWA 800N Icu 50-60 Hz IEC 947 - 2 VDE 0660 NEMA AB - 1 Ue V kA 220/240 380/415 440 500 690 250 Ics = 100% Icu 65 35 35 30 25 20 630/800 4000/8000 I DWA 800N-800 MR t Ir 1 Irm 0,9 I Ir x Ir 0,8 TEST 10 10 x Ir 10 Irm Irm Irm 5 30 Interruptor cerrado. Disjuntor ligado. Circuit-breaker in “ON” position. "O" Interruptor abierto. Disjuntor desligado. Circuit-breaker in “OFF” position. "1” Interruptor abierto por intervención de relés. Para volver a cerrar el interruptor, se deberá llevar la palanca hacia "2" I (posición extrema en 1 el rearme). Disjuntor desarmado por intervenção de reles. Para 0 religar o disjuntor deve-se 2 levar a alavanca até a posição “2” (Posição de rearme). Circuit-breaker tripped due to release operation. To reset the circuit-breaker, move the lever to position “2” (lever end position to reset the operating mechanism) and after to position “I”. . 5 x Ir 5 x Ir 30 AGUJEROS PARA FIJACIÓN INTERRUPTOR RM8x1.25 50 DIMENSIONES GENERALES DIMENSÕES GERAIS GENERAL DIMENSIONS 11.5 FURAÇÃO PARA FIXAÇÃO DO DISJUNTOR 25 13 25 DRILLING FOR FIXING CIRCUIT BREAKER 12.5 280 4POLOS 35 70 70 35 RM 5 =230= 70 140 113 108 98 RM12x1.75 210 3POLOS 70 106.5 13 13.5 33 14.7 8 CALADO DE PUERTA 22.5 257 323 230 103 231 On FURAÇÃO DA PORTA Off DRILLING OF DOOR 83 NEUTRO 70 104 70 8 77 14,7 82,5 33 13 13.5 NEUTRAL 78 SECCIONES DE CABLES Y BARRAS RECOMENDADAS CONFORME A IEC - 60947 - 1 SEÇÕES DE CABOS E BARRAS RECOMENDADOS CONFORME NORMA IEC - 60947 - 1 CABLES AND BARS SIZES RECOMMENDED ACCORDING TO IEC - 60947 - 1 CORRIENTE NOMINAL CORRENTE NOMINAL RATED CURRENT A SECCION DEL CABLE SEÇÃO DE CABOS CABLE SIZE mm 2 SECCION DE BARRA SEÇÃO DE BARRAS BAR SIZE mm 2 (Cu) (Cu) WEG Automação 250 320 400 500 630 800 120 185 1 x 240 2 x 95 2 x 150 2 x 185 2 x 240 3 x 150 20 x 6 40 x 5 40 x 6 50 x 6 50 x 8 2(50 x 5) 50 x 10 www.weg.net