Nuestro compromiso Elección fácil t 4ØMP WFSTJPOFT EF JOTUSVNFOUPT DPO P TJO TFOTPS OBEB NÈT :UPEBTMBTWFSTJPOFTTFTVNJOJTUSBODPOUPEPTMPTBDDFTPSJPTOFDFTBSJPT QBUSPOFTDBCMFTTPQPSUFTNBMFUBTTJTPOQPSUÈUJMFT y Sin gastos extras t 4PGUXBSFZDBCMFHSBUVJUPQBSBUPEBTMBTWFSTJPOFTEFJOTUSVNFOUPTRVF QVFEFODPOFDUBSTFB1$FYDFQUPEBUBMPHHFST 100% satisfacción del cliente t 1VFEFDBNCJBSPEFWPMWFSFMJOTUSVNFOUPTJOPDVNQMFTVTFYQFDUBUJWBT EÓBTTJOEFUFSJPSPEFJOTUSVNFOUPFNCBMBKFTNBOVBMFTyDPO DBSHPBEJDJPOBMEFSFBMNBDFOBKF Sólo marcas de máxima calidad Lo último en diseño t %FTEF MPT UFTUFST EF CPMTJMMP iXBUFSQSPPGw KPZBT FO NJOJBUVSB EFMBJOTUSVNFOUBDJØOTFDBMJCSBOBVUPNÈUJDBNFOUFTPOFTUBODPTDPO QBOUBMMBBNQMJBFOMBRVFTFJODMVZFOTF×BMFTEFBUFODJØO IBTUBMBTFSJF EFTPCSFNFTBNÈTBWBO[BEB La técnica más avanzada t -PT JOTUSVNFOUPT 94 VUJMJ[BO MB NÈT BWBO[BEB UFDOPMPHÓB QPS FKFNQMP MPT DJSDVJUPT "4*$ "QQMJDBUJPO 4QFDJýD *OUFHSBUFE $JSDVJU RVF JOUFHSBOOVNFSPTBTGVODJPOFTFOVOTPMPDIJQZDPNPSFTVMUBEPNFOPT DPNQPOFOUFTNBZPSTFHVSJEBE La importancia del detalle t $VJEBNPT IBTUB FM NÈT NÓOJNP EFUBMMF FNCBMBKFT NBOVBMFT BDDFTPSJPTyUPEPMPRVFVTUFEFTQFSBZNÈT Y además t 1MB[PTEFFOUSFHBCSFWFTMBNBZPSÓBFOIPSBT t "UFODJØOUFMFGØOJDBQFSTPOBMJ[BEB t 4PQPSUFUÏDOJDPEFBQMJDBDJPOFTZDVSTPTEFGPSNBDJØO PARA ELEGIR SU EQUIPO, ¡NO SE BASE SÓLO EN EL PRECIO! 1PSFTPPGSFDFNPTVOBBNQMJBWBSJFEBEEFNPEFMPTUBOUPQPSUÈUJMFT DPNPEFTPCSFNFTBBTÓQPEFNPTDVCSJSUPEBTTVTOFDFTJEBEFT Información detallada en: www.labprocess.es Síguenos en www.labprocess.es Índice de contenidos pH pH t5FTUFSTEFCPMTJMMP tQ)NFUSPQPSUÈUJM1PSUBWP tQ)NFUSPTQPSUÈUJMFT tQ)NFUSPTEFTPCSFNFTB t&MFDUSPEPTEFQ) t%JTPMVDJPOFTEFQ)SFEPYZNBOUFOJNJFOUPEFFMFDUSPEPT t1BQFMJOEJDBEPSEFQ)-ZQIBO t&MFDUSPEPTTFMFDUJWPTEFJPOFT $& $POEVDUJWJEBE t5FTUFSTEFCPMTJMMP t$POEVDUÓNFUSPTQPSUÈUJMFT t$POEVDUÓNFUSPTEFTPCSFNFTB t%JTPMVDJPOFTEFDPOEVDUJWJEBE OYÓHFOP%JTVFMUP t0YÓNFUSPTQPSUÈUJMFT .1 MVMUJQBSBNÏUSJDPT tQ)$%5.5%4$EFCPMTJMMP tQ)$%5.5%4$QPSUÈUJM tQ)$%5.5%40$EFTPCSFNFTB 5FNQFSBUVSB t5FSNØNFUSPTQPSUÈUJMFT t$FSUJýDBEPTEFUFNQFSBUVSB&/"$ t5FSNØNFUSPT-PX$PTU t5FSNØNFUSPTQPSUÈUJMFTJOGSBSSPKPT t5FSNPIJHSØNFUSPTQPSUÈUJMFT %BUB -PH %BUBMPHHFST $PMPS $PMPSJNFUSÓB t5FNQFSBUVSBZIVNFEBE64# t%BUBMPHHFSTQBSBBVUPDMBWF t%BUBOFUTJTUFNBJOBMÈNCSJDP t%BR-JOL t%BRQSP t$MPSØNFUSPTP[POPCSPNP t'PUØNFUSPT t3FBDUJWPT'PUØNFUSPTZ5VCFUFTU t5VSCJEÓNFUSPT t%JTPMVDJPOFTQBUSØOUVSCJEF[ t&TQFDUSPGPUØNFUSPT 5 ~ &TUVGBT t&TUVGBTFJODVCBEPSBT #B×PTEFBHVB t#B×PTEFBHVB Condiciones de venta Precios t /PJODMVZFOFM*7" t -PTQSFDJPTTPOWÈMJEPTIBTUBFMEF%JDJFNCSFEF&ODBTPEFDBNCJPJNQPS UBOUFEFQBSJEBEEFNPOFEBTOPTSFTFSWBNPTFMEFSFDIPBMBNPEJýDBDJØOEFQSFDJPT Envíos t 1PSUSBOTQPSUFVSHFOUF4&63 t 5SBOTQPSUFQPSDVFOUBZSJFTHPEFMEFTUJOBUBSJP t /PJODMVZFTFHVSP t /PTFSFTQPOEFEFEB×PTZPQÏSEJEBTPDBTJPOBEBTFOFMUSBOTQPSUF t %F OP JOEJDBS FYQMÓDJUBNFOUF FM NFEJP EF USBOTQPSUF Z USBOTQPSUJTUB FOUFOEF SFNPTRVFBDFQUBOFMOVFTUSP t 1PSUFT HSBUVJUPT B 1FOÓOTVMB Z #BMFBSFT QBSB QFEJEPT TVQFSJPSFT B é OFUP *7"BQBSUF t 1BSBJNQPSUFTJOGFSJPSFTTFDBSHBSÈOéFOGBDUVSB t &NCBMBKFTTJODBSHP t &O DBTP EF JODJEFODJB EFCF EF DPNVOJDBSTF QPS FTDSJUP B MB BHFODJB EF USBOTQPSUFFJOGPSNBSB-BCQSPDFTTEFOUSPEFMBTIPSBTTJHVJFOUFTBMBSFDFQDJØO Condiciones de pago t "M DPOUBEP MBT QSJNFSBT PQFSBDJPOFT Z QBSB DMJFOUFT DPO CBKB GSFDVFODJB EFDPNQSBNFEJBOUFUSBOTGFSFODJBPDIFRVFBOUJDJQBEP Domicilio bancario t -"$"*9"*#"/&4 Plazos de entrega t EF BSUÓDVMPT FO TUPDL QBSB FOUSFHB BOUFT EF IPSBT B MB SFDFQDJØO EFTVQFEJEP t "DVTF EF SFDJCP JONFEJBUP B TV QFEJEP DPO JOGPSNBDJØO EFM NBUFSJBM FYQFEJEP QBSBTVWFSJýDBDJØOEFQFEJEP ZEFMBGPSNBEFFOWÓP Lista de precios, catálogos, folletos… t 4PMJDJUFMPTFKFNQMBSFTRVFOFDFTJUF t *OGPSNBDJØOFTQFDJýDBDJPOFTOPUBTUÏDOJDBTZNBOVBMFTWFBOVFTUSPTJUJPXFC www.labprocess.es Garantía t -PT JOTUSVNFOUPT Z BDDFTPSJPT TVNJOJTUSBEPT QPS -BC1SPDFTT FTUÈO HBSBOUJ[BEPTDPOUSBEFGFDUPTEFGBCSJDBDJØOTFHÞOMBOPSNBFVSPQFB$&& -BGBMUBEFNBOUFOJNJFOUPBEFDVBEPZMBBMUFSBDJØOPDBNCJPEFBMHÞODPNQPOFOUF FYJNFBMGBCSJDBOUFEFUPEBSFTQPOTBCJMJEBETPCSFMPTEB×PTRVFQVFEBOQSPEVDJSTF t 7FSHBSBOUÓBRVFTFTVNJOJTUSBDPODBEBJOTUSVNFOUP Devoluciones t &O DBTP EF EFWPMVDJØO FTUB EFCF EF DPNVOJDBSTF QSFWJBNFOUF Z FM MÓNJUF EFBDFQUBDJØOFTEFEÓBTUSBTMBGFDIBEFWFOUB t 4JFNQSF TF FGFDUVBSÈ B QPSUFT QBHBEPT Z FM FNCBMBKF PSJHJOBM EFCF EF FTUBS FOQFSGFDUBTDPOEJDJPOFT t /P TF BENJUJSÈO EFWPMVDJPOFT EF FTUVGBT CB×PT EJTPMVDJPOFT DFSUJýDBEPT PNBUFSJBMFTFTQFDJBMFTIFDIPTBNFEJEBEFMVTVBSJP Propiedad de la mercancía t 5PEBT MBT NFSDBODÓBT TJHVFO TJFOEP EF OVFTUSB QSPQJFEBE IBTUB RVF FM DPNQSBEPSIBZBMJRVJEBEPUPEPTMPTQBHPTQFOEJFOUFT&MDPNQSBEPSUJFOFEFSFDIP BSFWFOEFSMBNFSDBODÓBQFSPOPTDFEFMPTEFSFDIPTBUÓUVMPEFTFHVSJEBESFTVMUBO UFTEFMBSFWFOUBIBTUBMJRVJEBDJØOEFUPEPTMPTQBHPTQFOEJFOUFT-PTMJUJHJPTTFSÈO WJTUPTFOMBKVSJTEJDDJØOEF#BSDFMPOB Soporte para aplicaciones gratuito Atención al público t %FBEFMVOFTBKVFWFT7JFSOFTEFB D%PDUPS'BVTo"MFMMB#BSDFMPOB Los productos que se muestran en este catàlogo han sido cuidadosamente seleccionados, siguiendo el criterio de escoger los más precisos, fiables y eficientes (tanto en función de especificaciones como de consumo energético) además del precio más ajustado. 4JOPFODVFOUSBBRVÓFMFRVJQPDPOMBTFTQFDJýDBDJPOFTSFRVFSJEBTQPS6EOPEVEFFODPOTVMUBSOPT www.labprocess.es 5 pH pHmetros de bolsillo Tester 5 &-'65630%&-".07*-*%"%&/464."/04 /VODBBOUFTDPOFTUBTFYUSBPSEJOBSJBTFTQFDJýDBDJPOFT t1BOUBMMBSFUSPJMVNJOBEBEFDPMPSFTB[VMQBSBNFEJEBWFSEFQBSBDBMJCSBDJØOZSPKBQBSBBMBSNB t/POFDFTJUBSÈOBEBNÈTDPOUBNQPOFTQ)QJMBTQBQFMUJTÞZWBTPEFDBMJCSBDJØO t*EFBMFTQBSBNFEJEBTSÈQJEBTFOBHSJDVMUVSBBHVBTKBSEJOFSÓBIJESPQØOJDBBDVJDVMUVSBQJTDJOBT Z41"4UPSSFTEFSFGSJHFSBDJØOFEVDBDJØO t$POFMFDUSPEPSFFNQMB[BCMF NPEFMPTDPOFMFDUSPEPSFFNQMB[BCMF · pH estándar · pH para punción (alimentos, semisólidos...) · Redox ESPECIFICACIONES TESTER PH 5 Y TESTER FOOD &TDBMBQ) y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO B 5BNQPOFTSFDPOPDJEPT 64" *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO Sí *OEJDBDJØOEFFTUBCJMJEBEEFNFEJEB Sí "MBSNBEFMFTUBEPEFMFMFDUSPEP Sí TESTER ORP Sí &TDBMBN7SFEPY 3FTPMVDJØON7 5FNQFSBUVSBFTDBMB$ y 3FTPMVDJØO1SFDJTJØO ¡$ 5FNQFSBUVSBDPNQFOTBDJØO .BOVBMPBVUPNÈUJDB "VUPBQBHBEP "MPTNJOUSBTQVMTBSVOBUFDMB 1BOUBMMB -$%%VBMSFUSPJMVNJOBEBBDPMPSFT -$%%VBMSFUSPJMVNJOBEBBDPMPSFT 1SPUFDDJØO*1 *1 *1 "MJNFOUBDJØO Y7"""QJMBT Y7"""QJMBT 7JEBEFMBTCBUFSÓBT IPSBT IPSBT %JNFOTJPOFT YQ) YQ)'PPE Y 1FTP HQ) HQ)'PPE H (BSBOUÓBJOTUSVNFOUPTFOTPS B×PTNFTFT B×PTNFTFT "MPTNJOUSBTQVMTBSVOBUFDMB Como pedirlo G-PHT5 pH5 Tester, completo con electrodo de pH, 1 cap para calibración, disoluciones tampón pH 7.00 + pH 4.01 (botellas de 55 ml coloreadas) 1 x 10 ml de solución de mantenimiento del electrodo, cinta de transporte, papel tisú, 4 pilas y maleta 120 € G-PHT5ECO pH Tester, sin maleta ni disoluciones 100 € G-PHFOODT5 pH5 FOOD, completo con electrodo de pH de penetración, 1 cap para calibración, disoluciones tampón pH 7.00 + pH 4.01 (botellas de 55 ml coloreadas) 1 x 10 ml de solución de mantenimiento del electrodo, cinta de transporte, papel tisú, 4 pilas y maleta 250 € G-ORPT5 ORP 5 Tester, completo con electrodo de redox, 1 cap para calibración, disolución patrón 468 mV (botella de 55 ml) 1 x 10 ml de solución de mantenimiento del electrodo, cinta de transporte, papel tisú, 4 pilas y maleta 130 € G-RPH5 Electrodo de recambio para pH5 Tester 45 € G-RORP5 Electrodo redox de recambio para pHORP Tester 70 € G-RPH5FOOD Electrodo de de recambio para pH5 FOOD Tester 150 € Accesorios Ver disoluciones patrón en página 19-20. 6 www.labprocess.es pH pHmetro de bolsillo Tester 1 -"&$0/0.*"&/46#0-4*--0 -JTUPTQBSBTVVTPOPOFDFTJUBSÈOBEBNÈTDPOUBNQPOFTEFQ)QBQFMUJTÞZWBTPEF DBMJCSBDJØO t"NQMJBQBOUBMMBDPOJOEJDBDJØOEFMPTUBNQPOFTVUJMJ[BEPTFOMBDBMJCSBDJØO t*OEJDBEPSEFFTUBCJMJEBEEFNFEJEB t$PNQFOTBDJØOBVUPNÈUJDBEFUFNQFSBUVSB t$BMJCSBDJØOFOQVOUPTBFMFHJSFOUSFQBUSPOFT64" t-BSHBWJEBEFGVODJPOBNJFOUPDPOQJMBTFTUÈOEBSEF7DPNQBUJCMFTDPOQJMBTSFDBSHBCMFT t4FOTPSýKPOPSFFNQMB[BCMF ESPECIFICACIONES TESTER PH 1 &TDBMBQ) y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO UJQP64" *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO Sí *OEJDBDJØOEFFTUBCJMJEBEEFNFEJEB Sí "MBSNBEFMFTUBEPEFMFMFDUSPEP Sí "VUPBQBHBEP "MPTNJOUSBTQVMTBSVOBUFDMB 1BOUBMMB -$% 1SPUFDDJØO*1 *1 "MJNFOUBDJØO Y7"""QJMBT 7JEBEFMBTCBUFSÓBT IPSBT %JNFOTJPOFT YNN 1FTP H (BSBOUÓBJOTUSVNFOUPTFOTPS B×PNFTFT Como se envia Como pedirlo G-PHT1 pH1 Tester, completo con 1 cap para calibración, disoluciones tampón pH 7.00 + pH 4.01 (botellas de 55 ml coloreadas) 1 x 10 ml de solución de mantenimiento del electrodo, cinta de transporte, papel tisú, 4 pilas y maleta 70 € G-PHT1ECO pH1 Tester, sin maleta ni disoluciones 62 € Ver disoluciones patrón en página 19-20. www.labprocess.es 7 pH Portavo 6/&953"03%*/"3*0*/4536.&/501035«5*-26&1&3.*5&.&%*3$0/&-&$530%04%&1) $0/%6$5*7*%"%:09¶(&/0%*46&-505"/50"/"-»(*$04$0.0$0/5&$/0-0(¶".&.04&/4 5BNCJÏONPEFMPTQBSBÈSFBTDPOQFMJHSPEFFYQMPTJØO Resistente "HPMQFTZBHFOUFTRVÓNJDPTFTUBODP*1*1ZNBOFKBCMFDPOVOB NBOPHSBDJBTBTVEJTF×PFYUSFNBEBNFOUFFTUSFDIP 'ÈDJMEFMJNQJBSFWJUBOEPRVFTFEFQPTJUFOSFTUPT Pantalla de vidrio anti reflejante 3FTJTUFOUFBSBZBEPTZBHFOUFTRVÓNJDPTHSÈýDBEFDPMPS27(" DPOEÓHJUPTEFNNEFBMUVSB (VÓBWJTVBMEFMNFOÞDPOTÓNCPMPTHSÈýDPTZFYQMJDBDJPOFT t1PSUBTFOTPSJOUFHSBEPRVFQSPUFHFZFWJUBRVFTFSFTFRVFFMFMFDUSPEP t5BQBEFQSPUFDDJØOQBSBMBQBOUBMMBZBMNJTNPUJFNQPDPNPQJFEFBQPZP tÁOJDPBQBSBUPQPSUÈUJMDPODFSUJýDBDJØO"5&9QBSB[POBTFHÞOWFSTJØO tIPSBTEFGVODJPOBNJFOUPDPOVOTPMPKVFHPEFQJMBT"" t*OEJDBDJØOEFDBNCJPEFQJMBTZBQBHBEPBVUPNÈUJDP t4FOTPGBDFRVFQSPQPSDJPOBJOGPSNBDJØOTPCSFFMFTUBEPEFMTFOTPS t*OGPSNBDJØOEFDBEVDJEBEEFDBMJCSBEP MODELO 907 SENSORES ANALÓGICOS PH / ORP .VMUJ$POE PH COND OXY t t t t t t t t t t t COND OXY SENSOR DE OXÍGENO ÓPTICO t t t t PH COND OXY .VMUJ0YZ 904 X PH / ORP COND t .VMUJQ) PH t t .VMUJ$POE .VMUJ0YZ 904 PH / ORP COND t .VMUJQ) t t .VMUJ0YZ 902 .VMUJQ) .VMUJ$POE PH / ORP COND t PH &TVOTJTUFNBJOUFMJHFOUFRVFHVBSEBZBOBMJ[BFOFMTFOTPSEBUPTSFMFWBOUFT DPNPFMOÞNFSPEFDBMJCSBDJPOFTFGFDUVBEBTZSFTVMUBEPTNFEJEBTUJFNQP EFVTPOEFTFSJFEFMTFOTPSyMPRVFQFSNJUFDBMJCSBSMPZHVBSEBSFMFMFDUSP EPDBMJCSBEP &TUBBDDJØOFTFYUSFNBEBNFOUFÞUJMQBSBMPTFMFDUSPEPTEFDPOUSPMEF QSPDFTPTZBRVFQFSNJUFHVBSEBSFMFDUSPEPTZBDBMJCSBEPTQBSBRVFFO FMNPNFOUPRVFEFCBOTVTUJUVJSTFQVFEBOIBDFSMPEFJONFEJBUPFWJUBOEP FOHPSSPTBTDBMJCSBDJPOFTiJOTJUVw -PTTFOTPSFT.FNPTFOTTPOFYUSBPSEJOBSJBNFOUFTFHVSPTZBRVFTVDP OFYJØOJOEVDUJWBUSBOTNJUFTJOOFDFTJEBEEFDPOUBDUPUBOUPMBFOFSHÓBDPNP MPTEBUPTFOUSFMPTTFOTPSFTZMPTJOTUSVNFOUPTDPOVOBJTMBNJFOUPHBMWÈOJDP QFSGFDUPZOPTFBGFDUBQPSDPOEJDJPOFTBNCJFOUBMFTDPNPIVNFEBETVDJF EBEDPSSPTJØOQPUFODJBMFTEFJOUFSGFSFODJBy www.labprocess.es COND t t Memosens® 8 SENSOR DE OXÍGENO ÓPTICO t t .VMUJ$POE SENSOR DIGITAL SENSOR DE OXÍGENO ÓPTICO COND t .VMUJQ) SENSORES MEMOSENS t OXY SENSOR DE OXÍGENO ÓPTICO pH 902 904 t t t t 907 t 1BOUBMMBDPMPS5'5BMUBSFTPMVDJØO 1BOUBMMBTFHNFOUPT $BMJCSBDJØOBVUPNÈUJDB$"-*."5*$ t t t t t t t t $BMJCSBDJØOBVUPNÈUJDBQBSBQBUSPOFT JOEJWJEVBMFTPFOUSBEBEFEBUPT t t t t t t 64#QBSBVQEBUF 64#QBSBDPNVOJDBDJØODPOQSPHSBNB1$1BSBMZ (VÓBEFVTPDPOJDPOPTZUFYUPTCSFWFT .ÞMUJQMFTJEJPNBT 4PGULFZT %BUBMPHHFS .FNPSJBQBSBEBUPT .FNPSJBQBSBEBUPT %JBHSBNBOFUXPSL $BMJCSBDJØO5JNFSyEÓBT 3FMPKUJFNQPSFBM $POFYJØOEFTFOTPSFT.FNPTFOT &TUBORVFJEBE*1 $PNQFOTBDJØOEFUFNQFSBUVSB/5$,û1U &TDBMBEFQ)Z3FEPY t t t t t t t t t t t t t t t t t N7 1VOUPTEFDBMJCSBDJØODPOSFDPOPDJNFOUPBVUPNÈUJDP 5FNQFSBUVSB$ )".*-50/)"$)858%*/3FBHFDPO "MJNFOUBDJØO Y""QJMBT*PO-JUJPDBSHBCMF64# %JNFOTJPOFTZQFTP YYNNH KP-PH902-3 Q)NFUSPQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)ZNBOVBMFTQB×PMZFMFDUSPEP1PMZQMBTU5&.1 %*/)".*-50/DPO$"5ZDBCMFýKP é KP-PH902-2 Q)NFUSPQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)ZNBOVBMFTQB×PM4*/&-&$530%0 OJ$"5OJDBCMF é KP-PH904-3 Q)NFUSPQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)ZNBOVBMFTQB×PMZFMFDUSPEP1PMZQMBTU 5&.1%*/)".*-50/DPO$"5ZDBCMFýKP KP-PH904-2 Q)NFUSPQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)ZNBOVBMZTPGUXBSF4*/&-&$530%0OJ $"5OJDBCMF KP-PH904X-2 Q)NFUSPQPSUÈUJM,OJDL9DPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)ZNBOVBMFTQB×PM 4*/&-&$530%0OJ$"5"5&9 é KP-PH907-2 Q)NFUSPQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBEJTPMVDJPOFTQ)Z40'58"3&DBCMF1$ZNBOVBMFTQB×PM 4*/4&/403OJ$"5OJDBCMF é é é Electrodos Memosens con sensor de temperatura ,14&/.4 &MFDUSPEPEFVTPHFOFSBMQ)$FMFDUSPMJUPHFMDVFSQPEFQMÈTUJDP4JODBCMF é ,14&/.4 &MFDUSPEPEFVTPHFOFSBMQ)$FMFDUSPMJUP,$.DVFSQPEFWJESJP4JODBCMF é ,1$".49'"- $BCMFQBSBTFOTPSFT.FNPTFOT-NZDPOFDUPS.EFQPMPTQBSB1PSUBWPUBNCJÏO"5&9 é Nota: Electrodos estándar, ver páginas "Electrodos" Accesorios G-CATK Compensador de temperatura para instrumentos KNICK, vaina de acero inoxidable, diá. 3 mm y 1 m cable con 2 bananas de diá. 4 mm. KP-ZU Batería de ion-litio + USB, para Portavo 904 y 907 80 € 148 € www.labprocess.es 9 pH pH 70 /6/$"1035"/10$04&$0/4*(6&5"/50 t(-1EBUBMPHHFSDPONFNPSJBTZTBMJEBEFEBUPTEJSFDUBNFEJBOUF64# t1BOUBMMBSFUSPJMVNJOBEBDPOJOEJDBDJØOEF .FEJEBEFQ)N7 Ì5FNQFSBUVSBÌ)PSBÌ1BUSPOFTVUJMJ[BEPTFOMBDBMJCSBDJØO t$PNQFOTBDJØOEFUFNQFSBUVSB.5$P"5$ t$POFDUPSFTUÈOEBS#/$RVFBENJUFDVBMRVJFSFMFDUSPEPEFQ)PSFEPY Y software gratis Características técnicas Q)FTDBMBEFNFEJEB pH 70 Q) 3FTPMVDJØO Q) 1VOUPTEFDBMJCSBDJØO Ø 5BNQPOFTSFDPOPDJEPT 64" /*45 *OEJDBDJØOEFQFOEJFOUFZQPUFODJBMEFBTJNFUSÓB N7FTDBMBEFNFEJEB 4ÓDPOGFDIBZIPSB N7 3FTPMVDJØO N7N7 N7 5FNQFSBUVSBFTDBMBEFNFEJEB 3FTPMVDJØO1SFDJTJØO $ $$ $PNQFOTBDJØOEFMBUFNQFSBUVSB/5$L "VUPNÈUJDBZNBOVBM 'VODJØO(-1 Sí "KVTUFEFMPTDSJUFSJPTEFFTUBCJMJEBEZNFEJEB Sí 5JNFS$BMJCSBDJØO Sí *OEJDBDJØOEFMPTUBNQPOFTVTBEPTFOMBDBMJCSBDJØO Sí -PX.FEJVN)JHI -$%-JRVJE$SZTUBM%JTQMBZ 3FUSPJMVNJOBEP 1BOUBMMB "VUPBQBHBEP "MPTNJOVUPT &OUSBEBT #/$+BDL1IPOP$"5 Z64# Y7QJMBT""" "EBQUBEPS"$%$DPODBCMF64# "MJNFOUBDJØO %VSBDJØOEFMBTCBUFSÓBT IPSBT (SBEPEFQSPUFDDJØO *1 %JNFOTJPOFTZQFTPJOTUSVNFOUP %JNFOTJPOFTZQFTPNBMFUB YYNNH YYNNH (1) Q)NFUSPQPSUÈUJMQ)94EFVTPHFOFSBMDPOFMFDUSPEPEFQ))BNJMUPO1PMZQMBTUEFQMÈTUJDPTFOTPSEFUFNQFSBUV SBQBUSPOFTEFQ)ZTPGUXBSFZDBCMFNJOJ64#BMJNFOUBEPS64#ZNBMFUB é (1) Q)NFUSPQPSUÈUJMQ)94EFVTPHFOFSBMDPOFMFDUSPEPEFQ)CÈTJDP-PX$PTUEFQMÈTUJDPZTFOTPSEFUFNQFSBUV SBQBUSPOFTEFQ)ZTPGUXBSFZDBCMFNJOJ64#BMJNFOUBEPS64#ZNBMFUB é (1) Q)NFUSPQPSUÈUJMQ)944*/&-&$530%0DPOTFOTPSEFUFNQFSBUVSBDBCMFEFFMFDUSPEPQBUSPOFTEFQ)Z TPGUXBSFZDBCMFNJOJ64#BMJNFOUBEPS64#ZNBMFUBVersión para que Ud. elija el electrodo que le convenga é Otras versiones completas G-PH70-5 pHmetro portátil pH70 XS para punción en alimentos, etc., electrodo de pH HAMILTON Double Pore, cable de electrodo, para penetración con vaina de vidrio, patrones de pH 7 y 4, software y cable mini-USB, alimentador USB, y maleta. Sin sensor de temperatura 595 € G-PH70-6 pHmetro portátil pH70 XS para punción en alimentos, etc., electrodo de pH para penetración con vaina de acero inoxidable y sensor de temperatura integrado, patrones de pH 7 y 4, software y cable mini-USB, alimentador USB, y maleta 553 € Electrodos ver página 14 a 17. 10 www.labprocess.es pH pHmetro portátil pH 7 &-1035«5*-#«4*$0.«44*.1-&:#"3"50 t$POFDUPSFTUÈOEBS#/$RVFBENJUFDVBMRVJFSFMFDUSPEPEFQ)PSFEPY tQVOUPTEFDBMJCSBDJØO64"P/*45$VTUPN t1BOUBMMBDPOJOEJDBDJØOEFQ)Z$JDPOPT t1SPUFHJEPDPOGVOEBEFHPNBSPCVTUB t$PONBMFUBFMFDUSPEPEFQ)DPOTFOTPS$EJTPMVDJPOFTQ)ZWBTPQMÈTUJDP Características técnicas pH 7 Q)FTDBMBEFNFEJEB Q) 3FTPMVDJØO Q) 1VOUPTEFDBMJCSBDJØO Ø 5BNQPOFTSFDPOPDJEPT 64"Q) /*45 WBMPSFTEFýOJEPTQPSFMVTVBSJP Sí *OEJDBDJØOEFQFOEJFOUFZQPUFODJBMEFBTJNFUSÓB N7FTDBMBEFNFEJEB N7 3FTPMVDJØO N7 5FNQFSBUVSBFTDBMBEFNFEJEB $ 3FTPMVDJØO1SFDJTJØO $$ $PNQFOTBDJØOEFMBUFNQFSBUVSB/5$L "VUPNÈUJDBZNBOVBM$ Sí "KVTUFEFMPTDSJUFSJPTEFFTUBCJMJEBEZNFEJEB Sí -PX.FEJVN)JHI *OEJDBDJØOEFMPTUBNQPOFTVTBEPTFOMBDBMJCSBDJØO -$%-JRVJE$SZTUBM%JTQMBZ 3FUSPJMVNJOBEP 1BOUBMMB "VUPBQBHBEP %FTQVÏTEFNJOVUPT &OUSBEBT #/$+BDL1IPOP$"5 "MJNFOUBDJØO Y7QJMBT""" %VSBDJØOEFMBTCBUFSÓBT IPSBT (SBEPEFQSPUFDDJØO*1 8BUFSQSPPG*1 %JNFOTJPOFTZQFTPJOTUSVNFOUP %JNFOTJPOFTZQFTPNBMFUB YYNNH YYNNH (1) Q)NFUSPQPSUÈUJMQ)94EFVTPHFOFSBMDPOFMFDUSPEPEFQ))BNJMUPO1PMZQMBTUEFQMÈTUJDPZTFOTPSEFUFNQFSBUV SBQBUSPOFTEFQ)ZZNBMFUB é (1) Q)NFUSPQPSUÈUJMQ)94EFVTPHFOFSBMDPOFMFDUSPEPEFQ)CÈTDJP-PX$PTUEFQMÈTUJDPDPOTFOTPSEFUFNQFSB UVSBQBUSPOFTEFQ)ZZNBMFUB é (1) Q)NFUSPQPSUÈUJMQ)944*/&-&$530%0DPOTFOTPSEFUFNQFSBUVSBDBCMFEFFMFDUSPEPQBUSPOFTEFQ)ZZ NBMFUBVersión para que Ud. elija el electrodo que le convenga é Otras versiones completas G-PH7-5 pHmetro portátil pH7 XS para punción en alimentos, etc., electrodo de pH HAMILTON Double Pore, cable de electrodo, para penetración de vidrio, patrones de pH 7 y 4 y maleta. Sin sensor de temperatura 540 € G-PH7-6 pHmetro portátil pH7 XS para punción en alimentos, etc., electrodo de pH para penetración con vaina de acero inoxidable y sensor de temperatura integrado, patrones de pH 7 y 4 y maleta 498 € Electrodos ver página 14 a 17. Otros accesorios G-CATNT55 Sonda CAT, NTC 30K de inmersión, diámetro 3 mm, cuerpo inox, para serie 7 y 70 70 € H-355173 Cable para electrodo con conector BNC 44 € G-50000112 Soporte articulado con base, para 3 sensores y 1 sonda de temperatura 70 € G-201T Electrodo de recambio "Low Cost", cuerpo de plástico, sonda CAT NTC 30K, 0...14 pH, 0...60 Cº y 1 m de cable conector BNC y jack para pHmetros XS 100 € Electrodos Hamilton ver páginas 14 a 18. www.labprocess.es 11 pH pHmetro de sobremesa pH 80 &"4:&4&-"%+&5*70%&-/6&704*45&." tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:#BTUBVOBNJSBEBZDPOPDFSÈDPORVFQBUSPOFTTFIBDBMJCSBEPMBFTUBCJMJEBEEFMFDUVSBMBUFNQFSBUVSBEFMBNVFTUSB GFDIBZIPSBFMFDUSPEPVUJMJ[BEPOPNCSFEFVTVBSJPZEFMBNVFTUSBTJFM64#FTUÈDPOFDUBEPyZFOQBOUBMMBBUPEPDPMPSJMVNJOBEB tEasy to learn:.BOVBMFOQBOUBMMBFOFTQB×PMPUSPTJEJPNBT tEasy to calíbrate:3FDPOPDJNJFOUPBVUPNÈUJDPEFQBUSPOFT64"/*45P%*/ t%PDVNFOUBDJØODPNQMFUB(-1 t/BEBPQDJPOBMUPEPJODMVJEPIBTUBFMTPGUXBSFZDBCMF t"HJUBEPSNBHOÏUJDPTFQBSBCMFEFGPSNBGÈDJMZPQFSBCMFTJOFOUSBSFOFMTPGUXBSF t4PQPSUFQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT Características técnicas pH 80 &TDBMBQ) y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO B 5BNQPOFTSFDPOPDJEPT 64"/*45%*/64&3 *OEJDBDJØOEFQVOUPTEF DBMJCSBDJØO Sí (-1$BMJCSBDJØO 4ÓDPOGFDIBZIPSB *OEJDBDJØOEFQFOEJFOUFZ0GGTFU 4ÓDPOGFDIBZIPSB *OEJDBDJØOEFFTUBEPEFM FMFDUSPEP 4ÓDPOJDPOP Sí $"-%6&DPOBMBSNB $SJUFSJPEFFTUBCJMJEBEEFNFEJEB -PX.FEJVN)JHI "MBSNB .*/."9 &TDBMBN7SFEPY 5FNQFSBUVSBFTDBMB$ y 3FTPMVDJØO1SFDJTJØO ¡$ 5FNQFSBUVSBDPNQFOTBDJØO .BOVBMPBVUPNÈUJDB/5$ ,û ¡$ Sí 5FNQFSBUVSBDBMJCSBDJØO Sí 4JTUFNB(-1 .FNPSJB ."/"650EBUPTDPO GFDIBZIPSB 1BOUBMMB .BUSJYNVMUJDPMPSDPOJDPOPT EJHJUBMZBOBMØHJDB &OUSBEBT #/$+BDLQIPOP"5$ 64# QBSBQSJOUFSP1$64#QBSB UFDMBEPFYUFSOP *EJPNB JEJPNBT Sí .BOVBM0OMJOF "HJUBEPSNBHOÏUJDP 4ÓSQN 1SPUFDDJØO*1 *1 "MJNFOUBDJØO "$%$BEBQUBEPS7o7 N" %JNFOTJPOFT YYNN 1FTP HS (1) Q)NFUSPEFTPCSFNFTBQ)94DPNQMFUPDPOBHJUBEPSNBHOÏUJDPFMFDUSPEPEFQ))BNJMUPO1PMJMZUF-"# DPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFTUBNQØOQ)ZNBOVBM é (1) Q)NFUSPEFTPCSFNFTBQ)94DPNQMFUPDPOBHJUBEPSNBHOÏUJDPDPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFT UBNQØOQ)ZNBOVBM4*/&-&$530%0$PODBCMFEFFMFDUSPEPVersión para que Ud. elija el electrodo adecuado a su necesidad é Accesorios 12 G-CATNT55 Sonda CAT, NTC 30K de inmersión, diámetro 3 mm , cuerpo inox, para series XS 70 € H-355173 Cable para electrodo con conector BNC 44 € G-TECLADO Teclado externo para Serie 80 G-PRINTER Impresora USB para Serie 80. (papel normal) www.labprocess.es 30 € 220 € pH pHmetro de sobremesa pH 8 &"4:&4&-"%+&5*70%&-/6&704*45&." tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:&OQBOUBMMBEFDPMPSFTDPOPDFSÈDPORVF QBUSPOFTTFIBDBMJCSBEPMBFTUBCJMJEBEEFMFDUVSBMBUFNQFSUVSB ZFMFTUBEPEFMFMFDUSPEP tEasy to calíbrate:3FDPOPDJNJFOUPBVUPNÈUJDPEFQBUSPOFT 64"P/*45 t"HJUBEPSNBHOÏUJDPPQDJPOBMTFQBSBCMFEFGPSNBGÈDJMZ VUJMJ[BCMFTJOOFDFTJEBEEFFOUSBSFOFMTPGUXBSF t4PQPSUFQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT Características técnicas pH 8 Basic/Stirrer &TDBMBQ) y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO 5BNQPOFTSFDPOPDJEPT 64"/*4564&3 *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO *OEJDBDJØOEFFTUBEPEFMFMFDUSPEP Sí Sí $SJUFSJPEFFTUBCJMJEBEEFNFEJEB .FEJVN &TDBMBN7SFEPY 3FTPMVDJØO 5FNQFSBUVSBFTDBMB$ y 3FTPMVDJØO1SFDJTJØO ¡$ 6OJEBE (1) (1) ¡$¡' 5FNQFSBUVSBDPNQFOTBDJØO .BOVBMPBVUPNÈUJDB/5$,û ¡$ Q)NFUSPEFTPCSFNFTBQ)94 DPNQMFUPDPOFMFDUSPEPEFQ) )BNJMUPO1PMJMZUF-BCDPNQFOTB EPSEFUFNQFSBUVSBEJTPMVDJPOFT UBNQØOQ)ZNBOVBM $POBHJUBEPSNBHOÏUJDP é Q)NFUSPEFTPCSFNFTBQ)94 DPNQMFUPDPODPNQFOTBEPSEF UFNQFSBUVSBEJTPMVDJPOFTUBNQØO é Q)DBCMFEFFMFDUSPEP ZNBOVBM4*/&-&$530%0 $POBHJUBEPSNBHOÏUJDP Sí 5FNQFSBUVSBDBMJCSBDJØO 1BOUBMMB .BUSJYDPMPSFT &OUSBEBT #/$+BDLQIPOP"5$ "HJUBEPSNBHOÏUJDPPQDJPOBM /0FOWFSTJØOCÈTJDB $POUSPMEFWFMPDJEBEEFMBHJUBEPS ($"5/5 4POEB$"5/5$,EFJONFS TJØOEJÈNFUSPNNDVFSQP JOPYQBSBTFSJFT94 é ) $BCMFQBSBFMFDUSPEPDPO DPOFDUPS#/$ é (45*33&3 "HJUBEPSNBHOFUJDPQBSBTFSJFZ DPOUSPMBEPQPSFMJOTUSVNFOUP SQN 1SPUFDDJØO*1 *1 "MJNFOUBDJØO "$%$BEBQUBEPS7 %JNFOTJPOFT YYNNTPMPJOTUSVNFOUP YYNNDPOBHJUBEPS 1FTP Accesorios HSTJOBHJUBEPSHSDPOBHJUBEPS é pH 50 '*"#-&&'*$*&/5&:"4&26*#-& t1BOUBMMB-$%SFUSPJMVNJOBEBDPOJOEJDBDJØOEFQ)PSFEPYZ$ t:DPOJDPOPEFFTUBEP t$BMJCSBDJØOIBTUBQVOUPTDPOSFDPOPDJNJFOUPBVUPNÈUJDP t.FNPSJBQBSBEBUPT - (1) Q)NFUSPEFTPCSFNFTBQ)94DPNQMFUPDPOCSB[PBSUJDVMBEPQBSBTFOTPSFTFMFDUSPEPEFQ)-PX$PTUZTFOTPSEF UFNQFSBUVSBEJTPMVDJPOFTQ)ZZNBOVBMFTQB×PM é (1) Q)NFUSPEFTPCSFNFTBQ)94DPNQMFUPDPOCSB[PBSUJDVMBEPQBSBTFOTPSFTDPNQFOTBEPSEFUFNQFSBUVSBDBCMF#/$ QBSBFMFDUSPEPEJTPMVDJPOFTQ)ZZNBOVBMFTQB×PM4*/&-&$530%0 é www.labprocess.es 13 pH Electrodos de pH y Redox $0/0$*%041034613&$*4*»/"-5"$"-*%"%-"3("7*%"Á5*-:6/3&/%*.*&/50*/.&+03"#-& tGLPDPOOÞNFSPEFDBUÈMPHPEFTFSJFZMPUFEF GBCSJDBDJØOFOFMJOUFSJPSEFMDVFSQPEFMFMFDUSPEP JNCPSSBCMF tEcológicosVUJMJ[BOWJESJPFYFOUPEFQMPNPZ FMFDUSPMJUPTTJOBDSJMBNJEB tErgonómicosDBCF[BEFMFMFDUSPEPBOUJSPEBOUFZ QSPUFDUPSDPODJFSSFEFGÈDJMFYUSBDDJØOZBQSVFCBEF EFSSBNFT tLíquido interno coloreadoB[VMQBSBBEWFSUJSEF QPTJCMFTCVSCVKBTFOMBNFNCSBOBEFMFMFDUSPEP Con certificado de calidad nº de fabricación, resultados del control, tiempo de respuesta y especificaciones Hemos seleccionado los electrodos de pH y redox, de tal manera que con los contenidos en este catálogo solucionan el 99% de las aplicaciones, no obstante si tienen alguna aplicación especifica y no encuentra aquí el electrodo adecuado, Hamilton tiene la solución, contacte con Labprocess. De uso general, cuerpo de vidrio LIQ-GLASS 6/40-0&-&$530%01"3"-".":03¶"%&.&%*%"4.6-5*5"3&" 7«-*%01"3".&%*35".10/&453*4:'04'"504 &-.«47&/%*%0 &TDBMBEFNFEJEB yQ) 5FNQFSBUVSBEFUSBCBKP $ &MFNFOUPEFSFGFSFODJB &WFSFG %JBGSBHNB $FSÈNJDP &MFDUSPMJUP ,$*.PM .FNCSBOB $JMÓOESJDB)' %JÈNFUSP NN .BUFSJBMEFMDVFSQP 7JESJP *ONFSTJØONÓOJNB HAMILTON $BU/ 4FOTPSEFUFNQFSBUVSB $BCF[BPDPOFDUPS 1BSBQ)NFUSPT Precios 14 NN Liq-Glass Liq-Glass BNC Liq-Glass Temp BNC Liq-Glass Temp BNC Liq-Glass Temp DIN Liq-Glass Temp LEMO ) ) ) ) ) ) /P /P 1U /5$, /5$, 1U 4 NDBCMF#/$ NDBCMF #/$ CBOBOB NN NDBCMF #/$ KBDL$*/$) NDBCMF %*/ CBOBOB NN NDBCMF -&.0 CBOBOBT NN 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT 94&VUFDI$SJTPO 0SJPO)BOOB.FUUMFS 4BSUPSJVT $SJTPO 94.FUUMFS ,OJDL858 4DIPUU .FUSPIN 159 € 190 € 275 € 275 € 275 € 325 € www.labprocess.es pH Polilyte LAB 4*//&$&4*%"%%&3&--&/0%&&-&$530-*50 t6TPHFOFSBMFODVBMRVJFSBQMJDBDJØOBDVPTBJODMVJEPFNVMTJPOFTZTVTQFOTJPOFT t#BKPNBOUFOJNJFOUP t$POTJTUFNB4*/(-&103&¥RVFFWJUBMBDPOUBNJOBDJØOEFMEJBGSBHNBPQVFOUFTBMJOP &TDBMBEFNFEJEB yQ) 5FNQFSBUVSBEFUSBCBKP $ &MFNFOUPEFSFGFSFODJB &WFSFG# %JBGSBHNB 4JOHMF1PSF &MFDUSPMJUP 1PMJTPMWF .FNCSBOB $JMÓOESJDB)' %JÈNFUSP NN .BUFSJBMEFMDVFSQP 7JESJP *ONFSTJØONÓOJNB NN Polylite Lab Polylite Lab Temp BNC Polylite Lab Temp BNC Polylite Lab Temp DIN ) ) ) ) /P 1U /5$, /5$, 4 NDBCMF#/$ CBOBOBNN NDBCMF#/$ KBDL$*/$) NDBCMF%*/ CBOBOBNN 94&VUFDI,OJDL$SJTPO0SJPO )BOOB.FUUMFS8584BSUPSJVT $SJTPO 94.FUUMFS ,OJDL8584DPUU 159 € 249 € 249 € 240 € HAMILTON $BU/ 4FOTPSEFUFNQFSBUVSB $BCF[BPDPOFDUPS 1BSBQ)NFUSPT Precios De uso general con cuerpo de plástico Polyplast 1"3"1035«5*-&4%&1-«45*$0 3&/%*.*&/50&9$&1$*0/"&TDBMBEFNFEJEB yQ) 5FNQFSBUVSBEFUSBCBKP $ &MFNFOUPEFSFGFSFODJB "H"H$* %JBGSBHNB 4JOHMF1PSF &MFDUSPMJUP 1PMJTPMWF .FNCSBOB $JMÓOESJDB %JÈNFUSP NN .BUFSJBMEFMDVFSQP 1MÈTUJDP *ONFSTJØONÓOJNB NN HAMILTON $BU/ Polyplast Polyplast BNC* ) ) 4FOTPSEFUFNQFSBUVSB /P /P $BCF[BPDPOFDUPS 4 NDBCMF#/$ 94&VUFDI,OJDL$SJTPO0SJPO )BOOB.FUUMFS8584BSUPSJVT 94&VUFDI$SJTPO0SJPO)BOOB .FUUMFS4BSUPSJVT 1BSBQ)NFUSPT Precios * Según el cable utilizado. 97 € 115 € * Sin certificado. www.labprocess.es 15 pH Electrodos para alimentación Double Pore Double Pore PEEK $BU/ HAMILTON ) $BU/ ) ) &TDBMBEFNFEJEB Q) &TDBMBEFNFEJEB Q) Q) 5FNQFSBUVSBEF 5SBCBKP$ $ $ &MFNFOUPEFSFGFSFODJB "H"H$M "H"H$M 5FNQFSBUVSBEF 5SBCBKP$ &MFNFOUPEFSFGFSFODJB %JBGSBHNB Foodtrode $ &WFSFG HAMILTON DFSÈNJDPT %JBGSBHNB 4JOHMF1PSF 4JOHMF1PSF &MFDUSPMJUP 1SPUFMZUF &MFDUSPMJUP 1PMJTPMWF 1PMJFUFD .FNCSBOB $JMÓOESJDB .FNCSBOB 1VOUB 1VOUB %JÈNFUSP NN NN .BUFSJBMEFMDVFSQP 7JESJP 1&&, NN NN 4 4 %JÈNFUSP .BUFSJBMEFMDVFSQP *ONFSTJØONÓOJNB NN 7JESJP NN 4FOTPSEFUFNQFSBUVSB $BCF[BPDPOFDUPS 1BSBQ)NFUSPT TFHÞODBCMFVUJMJ[BEP "QMJDBDJPOFT Precio *ONFSTJØONÓOJNB 4FOTPSEFUFNQFSBUVSB 4 94&VUFDI,OJDL $SJTPO0SJPO )BOOB.FUUMFS 8584BSUPSJVT 1BSBNFEJPTDPO QSPUFÓOBTTVFSPT MFDIFDBDBPZPHVS [VNPTQBTUBNBTBT EFQBOZNFSNFMBEB $BCF[BPDPOFDUPS 1BSBQ)NFUSPT 94&VUFDI,OJDL$SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT "QMJDBDJPOFT Precio 1FOFUSBDJØOFOTØMJEPTZTFNJTØMJEPT DBSOFTRVFTPTGSVUBTWFHFUBMFT FNCVUJEPT.FEJDJØOFOQFRVF×PT WPMÞNFOFTEFNVFTUSB 249 € 259 € 219 € Electrodo “Todo terreno” 5".#*²/--"."%0i1"3".&%*047*4$0404w HAMILTON ) &TDBMBEFNFEJEB Q) 5FNQFSBUVSBEF 5SBCBKP$ &MFNFOUPEFSFGFSFODJB $ &WFSFG $BU/ Penetración T / inox Penetración T / vidrio ( ( &TDBMBEFNFEJEB Q) Q) 5FNQFSBUVSBEF 5SBCBKP$ $ $ &MFNFOUPEFSFGFSFODJB "H"H$M "H"H$M 4JOHMF1PSF %JBGSBHNB "OJMMPEF15'& &MFDUSPMJUP ,$M.PM %JBGSBHNB DFSÈNJDP 4JOHMF1PSF .FNCSBOB $JMÓOESJDB &MFDUSPMJUP 1PMJFUFD 1PMJTPMWF NN .FNCSBOB 1VOUB 1VOUB %JÈNFUSP NN NN %JÈNFUSP .BUFSJBMEFMDVFSQP *ONFSTJØONÓOJNB 4FOTPSEFUFNQFSBUVSB $BCF[BPDPOFDUPS 7JESJP NN .BUFSJBMEFMDVFSQP /0 *ONFSTJØONÓOJNB 4 4FOTPSEFUFNQFSBUVSB 1BSBQ)NFUSPT TFHÞODBCMFVUJMJ[BEP 94&VUFDI,OJDL$SJTPO 0SJPO)BOOB.FUUMFS 8584BSUPSJVT "QMJDBDJPOFT 7JOPTNPTUPTZWJOBHSFT "HVBTQVSBTZEFTUJMBEBT "DFJUFTZHSBTBT $PTNÏUJDPTZDSFNBT 1SPEVDUPTWJTDPTPT 5JOUFTDPMPSBOUFTZQJOUVSBT Precio 16 Flushtrode $BU/ 219 € www.labprocess.es $BCF[BPDPOFDUPS *OPY 7JESJP NN NN /5$, /5$, $BCMF#/$ $JODI $BCMF#/$ $JODI 1BSBQ)NFUSPT 94.FUUMFSWFS 94.FUUMFSWFS TJPOFTQBSBPUSPT TJPOFTQBSBPUSPT Q)NFUSPT Q)NFUSPT "QMJDBDJPOFT 1FOFUSBDJØOFOTØMJEPTZTFNJTØMJEPT DBSOFT RVFTPTGSVUBTWFHFUBMFT Precio 195 € 155 € pH Electrodos de pH a medida de sus necesidades Single Pore Glass Flatrode Filltrode Slimtrode Minitrode $BU/ HAMILTON ) ) ) ) ) &TDBMBEFNFEJEB Q) Q) Q) Q) Q) 5FNQFSBUVSBEF 5SBCBKP$ $ $ $ $ $ &MFNFOUPEFSFGFSFODJB &WFSFG &WFSFG &WFSFG &WFSFG &WFSFG %JBGSBHNB 4JOHMFQPSF "OVMBS "OVMBS $FSÈNJDP $FSÈNJDP &MFDUSPMJUP 4LZMJUF$- 4LZMJUF$- 4LZMJUF$- ,$M.PM ,$M.PM .FNCSBOB $JMÓOESJDB 1MBOB 1MBOB $JMÓOESJDB $JMÓOESJDB NN NN NN NN NN 7JESJP 1MÈTUJDP 1MÈTUJDP 7JESJP 7JESJP NN NN NN NN NN %JÈNFUSP .BUFSJBMEFMDVFSQP *ONFSTJØONÓOJNB $BCF[BPDPOFDUPS 4 4 4 4 4 1BSBQ)NFUSPT 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT 94&VUFDI,OJDL $SJTPO0SJPO)BOOB .FUUMFS8584BSUPSJVT "QMJDBDJPOFT "HVBPYJHFOBEBQFSØYJ EPEFIJESØHFOP 4VQFSýDJFTQMBOBTQB QFMUFKJEPQJFMHFMFT )'1BTUBEFOUÓGSJDB &NVMTJPOFTZ TVTQFOTJPOFT 234 € 256 € 235 € Precio $POEJÈNFUSPTEFZNNQBSBNFEJS FONJDSPNVFTUSBT 250 € 295 € Electrodos Redox (mV) &-&$530%04.&5«-*$041"3".&%*%"4%&105&/$*"- 3&%09:5*53"$*0/&4 Liq-Glass ORP (redox) Polyplast ORP (redox) Polyplast ORP BNC (redox) Liq-Glass Ag (argentometrías) $BU/ HAMILTON ) ) ) ) &TDBMBEF NFEJEB N7 N7 N7 N7 $ $ $ $ &WFSFG "H"H$M "H"H$M &WFSFG %JBGSBHNB $FSÈNJDP 4JOHMFQPSF 4JOHMFQPSF $FSÈNJDP &MFDUSPMJUP ,$M.PM 1PMJTPMWF 1PMJTPMWF ,/0. 5FNQFSBUVSBEF 5SBCBKP$ &MFNFOUPEF SFGFSFODJB .FNCSBOB 1MBUJOP 1MBUJOP 1MBUJOP 1MBUB %JÈNFUSP NN NN NN NN 7JESJP 1MÈTUJDP 1MÈTUJDP 7JESJP *ONFSTJØO NÓOJNB NN NN NN NN $BCF[BP DPOFDUPS 4 4 NDBCMF#/$ 4 94&VUFDI$SJTPO0SJPO )BOOB.FUUMFS4BSUPSJVT 94&VUFDI,OJDL$SJTPO0SJPO )BOOB.FUUMFS8584BSUPSJVT 149 € 195 € .BUFSJBMEFM DVFSQP 1BSBQ)NFUSPT Precio 94&VUFDI,OJDL$SJTPO0SJPO 94&VUFDI,OJDL$SJTPO0SJPO )BOOB.FUUMFS8584BSUPSJVT )BOOB.FUUMFS8584BSUPSJVT 265 € 120 € www.labprocess.es 17 pH Electrodos de referencia 4, &MFDUSPEPEFSFGFSFODJBEPCMFQVFOUFZDBCMFDPOFDUPSCBOBOBNN é 4,# &MFDUSPEPEFSFGFSFODJBEPCMFQVFOUFZDBCMFDPOFDUPSCBOBOBNN é Cables para electrodos, con conector para instrumento -PTFMFDUSPEPTDPOTFOTPSEFUFNQFSBUVSBJOUFHSBEPMMFWBODBCMFýKPEFUBMNBOFSBRVFTØMPEFCFFTDPHFSTFFMDPOFDUPS DPSSFTQPOEJFOUFBMJOTUSVNFOUPFODBNCJPMPTFMFDUSPEPTDPODBCF[BEFSPTDBMPTNÈTVTVBMFTVUJMJ[BOMBDPOFYJØO"4 &TUBDPOFYJØOFTMBNÈTDPNÞO&OFTUFDBTPTFOFDFTJUBVODBCMFDPOFMDPOFDUPS#/$%*/-&.0FUDBEFDVBEPB DBEBQ)NFUSPTFHÞOTVNBSDB H-355173 $BCMF"4.#/$QBSBQ)NFUSPTDPODPOFDUPS#/$ é H-355176 $BCMF"4.#/$QBSBQ)NFUSPTDPODPOFDUPS#/$ é H-355174 $BCMF"4.%*/QBSBQ)NFUSPTDPODPOFDUPS%*/,OJDL4DIPUU858 é H-355177 $BCMF"4.%*/QBSBQ)NFUSPTDPODPOFDUPS%*/,OJDL4DIPUU858 é H-355175 $BCMF"4.-&.0QBSBQ)NFUSPT.FUSPINOVFWPT é H-B1N $BCMF"4.CBOBOBNNQBSBFMFDUSPEPTEFSFGFSFODJB é H-B1P $BCMF"4.CBOBOBNN64" QBSBFMFDUSPEPTEFSFGFSFODJB é Accesorios ( 4PQPSUFBSUJDVMBEPDPOCBTFQBSBTFOTPSFTZTPOEBEFUFNQFSBUVSB é 5VCPQSPUFDUPSQBSBFMFDUSPEPTEJÈNFUSPNNQBSBBMNBDFOBNJFOUP é 4PQPSUFBSUJDVMBEP Certificado de calibración de pHmetros 4FVUJMJ[BFOMBDFSUJýDBDJØOMBTEJTPMVDJPOFTQBUSØO)".*-50/DVZPTMPUFTFTUÈODFSUJýDBEPTQPSFM%"LL4%FVUTDIF "LLSFEJUJJFSVOHTTUFMMF(NC) SFDPOPDJEPFOUSFMPTJOTUJUVUPTFVSPQFPTEFQSFTUJHJPJODMVJEP&/"$ 5BNCJÏOTFVUJMJ[BOMPTDPSSFTQPOEJFOUFTTJNVMBEPSFTEFUFNQFSBUVSBZQ)DFSUJýDBEPT &OFMDFSUJýDBEPTFSFQSFTFOUBOMPTWBMPSFTPCUFOJEPTFOMBDBMJCSBDJØOEFMJOTUSVNFOUPJODFSUJEVNCSF USB[BCJMJEBEQSPDFEJNJFOUPDPOEJDJPOFTQBUSPOFTVUJMJ[BEPTFUD 18 LP-51-08 $BMJCSBDJØOQ)NFUSPEFQPSUÈUJM é LP-51-03 $BMJCSBDJØOQ)NFUSPEFTPCSFNFTB é www.labprocess.es pH Disoluciones Tampón pH $&35*'*$"%"4%,%&/"$53";"#-&4/*45:15# `")0330:13&$*4*»/4»-0.-103$"-*#3"$*»/ t6OBCPUFMMBEFNM FGFDUVBOEPVOBDBMJCSBDJØO EJBSJBUJFOFNFTFTEFEVSBDJØO 4JFMDPOUFOJEPEFMWBTP JOUFHSBEPEFMBCPUFMMBMP NBOUJFOFVOBTFNBOB FOUPODFTVOBCPUFMMBMF EVSBSÈØNFTFT t-BQSFDJTJØOEFMBNFEJEB EFQ)EFQFOEFCÈTJDBNFOUF EFMBVUJMJ[BDJØOEFVO CVFOQBUSØO t*NNVOFTBMPT NJDSPPSHBOJTNPT t#05&--"4%&1-«45*$0%&:NM DPOWBTPEFDBMJCSBDJØOJOUFHSBEPDPOWÈMWVMB QBSBFWJUBSFMSFUPSOPBCPUFMMB Fácil usoCBTUBEFTUBQBSMBCPUFMMBQSFTJPOBSQBSBMMFOBS FMWBTPEFDBMJCSBDJØOJOUSPEVDJSFMTFOTPSZDBMJCSBS FiableFMQBUSØODPOUFOJEPFOMBCPUFMMBOPTFQVFEF DPOUBNJOBSHSBDJBTBMBWÈMWVMBFOUSFFMWBTPZMBCPUFMMB SeguroHSBDJBTBMDPMPSEFDBEBQBUSØOTFJEFOUJýDBEF JONFEJBUP EconómicoNFOPTDBOUJEBEEFUBNQØOQBSBDBEBDBMJCSBDJØO TrazableDPODFSUJýDBEP%,%SFDPOPDJEPQPS&/"$ H-238317 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238217 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238917 %JTPMVDJØOUBNQØOQ)Q)$DBKBEFYNMDFSUJýDBEP%,%&/"$ é H-238318 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238218 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238918 %JTPMVDJØOUBNQØOQ)Q)$DBKBEFYNMDFSUJýDBEP%,%&/"$ é H-238319 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238219 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238919 %JTPMVDJØOUBNQØOQ)Q)$DBKBEFYNMDFSUJýDBEP%,%&/"$ é H-238321 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238223 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP%,%&/"$ é H-238923 %JTPMVDJØOUBNQØOQ)Q)$DBKBEFYNMDFSUJýDBEP%,%&/"$ é H-238922 +VFHPEFEJTPMVDJPOFTUBNQØOQ)ZYNMDFSUJýDBEP%,%&/"$ é H-238924 +VFHPEFEJTPMVDJPOFTUBNQØOQ)ZYNMDFSUJýDBEP%,%&/"$ é H-238271 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238272 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238273 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238274 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238275 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238276 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238277 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238278 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é H-238279 %JTPMVDJØOUBNQØOQ)Q)$YNMDFSUJýDBEP)".*-50/ é * Bajo demanda www.labprocess.es 19 pH Disoluciones Tampón pH $0-03&"%"41"3".":034&(63*%"% $0/#05&--""/5*$0/5".*/"$*»/:$&35*'*$"%0/*45 %&4$"3("#-&%&4%&-"1«(*/"8&# (SBDJBTBMWBTPJOUFHSBEPFOMBCPUFMMB t&WJUBSÈMBDPOUBNJOBDJØO t&MJNJOBFMUSBOTWBTFBPUSPTSFDJQJFOUFT t"IPSSPNFOPTDBOUJEBEEFUBNQØOVUJMJ[BEB t.BZPSQSFDJTJØO ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é ( %JTPMVDJØOUBNQØOQ)Q)$YNM é Cubitainers de 5 litros t(SJGPJODPSQPSBEP t&OWPMWFOUFPQBDPQBSBFWJUBSMBMV[ t5BNB×PNBOFKBCMFZEFGÈDJMUSBOTQPSUF t%JTPMVDJPOFTDPMPSFBEBTTFHÞOOPSNBT t$FSUJýDBEBTUSB[BCMFTB/*45/BUJPOBM*OTUJUVUFPG4UBOEBSETBOE5FDIOPMPHZ ( %JTPMVDJØOUBNQØOQ)Q)$$VCJUBJOFSEFMJUSPT é ( %JTPMVDJØOUBNQØOQ)Q)$$VCJUBJOFSEFMJUSPT é ( %JTPMVDJØOUBNQØOQ)Q)$$VCJUBJOFSEFMJUSPT é Disoluciones Patrón Redox ) %JTPMVDJØOQBUSØOSFEPYN7YNM)".*-50/ é ) %JTPMVDJØOQBUSØOSFEPYN7YNM)".*-50/CPUFMMBDPOSFDJQJFOUFEFDBMJCSBDJØOJOUFHSBEP é ) %JTPMVDJØOQBUSØOSFEPYN7YNM)".*-50/CPUFMMBDPOSFDJQJFOUFEFDBMJCSBDJØOJOUFHSBEP é 0USPTWBMPSFTCBKPEFNBOEBZN7 ( 20 %JTPMVDJØOQBUSØOSFEPYN7YNM www.labprocess.es é pH Disoluciones Electrolíticas "$ ,$M.YNM94 é ) ,$M.YNM)".*-50/ é "$ ,$M.YNM94 é ) 4LZMZUF$-YNM)".*-50/ é ) 4LZMZUFYNM)".*-50/ é ) 1SPUFMZUFYNM)".*-50/ é "$ ,/0.QBSBFMFDUSPEPTEFQMBUBYNM94 é "$ -J$M.FOFUBOPMQBSBNFEJEBTFONFEJPTOPBDVPTPTYNM94 é Disoluciones para mantenimiento de electrodos ) .BOUFOJNJFOUPZDPOTFSWBDJØOEFFMFDUSPEPTYNM)".*-50/ é "$ -JNQJBQSPUFÓOBTQFQTJOB)$M YNM94 é "$ -JNQJBEJBGSBHNBTUJPVSFB)$M YNM94 é "$ 3FHFOFSBEPSEFNFNCSBOBT)' YNM é www.labprocess.es 21 pH Papel indicador de pH Lyphan $0.1-&5"("."26&$6#3&50%0&-3"/(0 %&1)&/*/5&37"-04%&0: t5FTUTSÈQJEPTZQSFDJTPTFOTPMVDJPOFTBDVPTBT DMBSBTUVSCJBTZUF×JEBT t"MUBQSFDJTJØOEFCJEPBMBT[POBTCJFOEFMJNJUBEBT JOEJDBEPSBTEFQ)FOMPTSPMMPTEFQ)-ZQIBO t-FDUVSBMFHJCMFCBKPUPEBTMBTDPOEJDJPOFTQPTJCMFTEFMV[ t-BSHBWJEBEFBMNBDFOBKFTJTFBMNBDFOBOFO DPOEJDJPOFTBEFDVBEBTEFPTDVSJEBEZCBKBIVNFEBE Rollos de 6 metros de papel indicador L-R014 1 rollo original de 6 m, caja de plástico con escala de color, pH 0.0 … 14.0 14,73 € L-R111 1 rollo original de 6 m, caja de plástico con escala de color, pH 1.0 … 11.0 11,65 € L-R6999 1 rollo original de 6 m, caja de plástico con escala de color, pH 6.9 … 9.9 11,17 € L-R4979 1 rollo original de 6 m, caja de plástico con escala de color, pH 4.9 … 7.9 11,17 € L-R3969 1 rollo original de 6 m, caja de plástico con escala de color, pH 3.9 … 6.9 11,17 € Rollos de recambio para cajas anteriores L-NF014 1 rollo de recambio de 6 m, de papel indicador Lyphan, pH 0.0 … 14.0 14,08 € L-NF111 2 rollos de recambio de 6 m, de papel indicador Lyphan, pH 0.1 … 11.0 16,99 € Cajas de 200 tiras indicadoras de pH a intervalos de 0.3 pH L-L650 1 caja de 200 tiras de papel indicador Lyphan, pH 0.4 … 1.4 11,17 € L-L651 1 caja de 200 tiras de papel indicador Lyphan, pH 1.0 … 2.8 11,17 € L-L652 1 caja de 200 tiras de papel indicador Lyphan, pH 1.6 … 3.7 11,17 € L-L656 1 caja de 200 tiras de papel indicador Lyphan, pH 2.6 … 4.1 12,79 € L-L658 1 caja de 200 tiras de papel indicador Lyphan, pH 2.6 … 4.7 11,17 € L-L659 1 caja de 200 tiras de papel indicador Lyphan, pH 2.4 … 4.3 (para alimentación) 11,17 € L-L662 1 caja de 200 tiras de papel indicador Lyphan, pH 3.9 … 5.4 12,79 € L-L664 1 caja de 200 tiras de papel indicador Lyphan, pH 4.3 … 6.1 11,17 € L-L665 1 caja de 200 tiras de papel indicador Lyphan, pH 5.2 … 6.7 12,79 € L-L668 1 caja de 200 tiras de papel indicador Lyphan, pH 6.0 … 7.5 12,79 € L-L669 1 caja de 200 tiras de papel indicador Lyphan, pH 6.6 … 8.1 12,79 € L-L670 1 caja de 200 tiras de papel indicador Lyphan, pH 6.0 … 8.1 11,17 € L-L671 1 caja de 200 tiras de papel indicador Lyphan, pH 7.5 … 8.7 12,79 € L-L672 1 caja de 200 tiras de papel indicador Lyphan, pH 6.6 … 8.7 11,17 € L-L674 1 caja de 200 tiras de papel indicador Lyphan, pH 8.2 … 9.7 11,17 € L-L677 1 caja de 200 tiras de papel indicador Lyphan, pH 8.8 … 10.0 11,17 € L-L680 1 caja de 200 tiras de papel indicador Lyphan, pH 9.4 … 10.3 11,17 € L-L683 1 caja de 200 tiras de papel indicador Lyphan, pH 10.1 … 11.3 11,17 € L-L695 1 caja de 200 tiras de papel indicador Lyphan, pH 9.0 … 14.00 11,17 € L-L698 1 caja de 200 tiras de papel indicador Lyphan, pH 10.5 … 13.00 11,17 € L-L699 1 caja de 200 tiras de papel indicador Lyphan, pH 11.5 … 14.0 11,17 € L-L701 1 caja de 200 tiras de papel indicador Lyphan, pH 11.0 … 13.1 11,17 € Cajas de 200 tiras indicadoras de pH a intervalos de 0.2 pH L-L653-8 1 caja de 200 tiras de papel indicador Lyphan, pH 1.8 ….3.2 12,79 € L-L656-8 1 caja de 200 tiras de papel indicador Lyphan, pH 3.0 ….4.4 12,79 € L-L662-8 1 caja de 200 tiras de papel indicador Lyphan, pH 3.9 … 5.3 12,79 € L-L665-8 1 caja de 200 tiras de papel indicador Lyphan, pH 5.2 … 6.6 12,79 € L-L666-8 1 caja de 200 tiras de papel indicador Lyphan, pH 6.0 … 7.4 12,79 € L-L667-8 1 caja de 200 tiras de papel indicador Lyphan, pH 6.6 … 8.0 12,79 € L-L668-8 1 caja de 200 tiras de papel indicador Lyphan, pH 5.6 … 7.0 12,79 € L-L669-8 1 caja de 200 tiras de papel indicador Lyphan, pH 6.6 … 8.0 12,79 € L-L671-8 1 caja de 200 tiras de papel indicador Lyphan, pH 7.3 … 8.7 12,79 € L-L676-8 1 caja de 200 tiras de papel indicador Lyphan, pH 8.6 … 10.0 12,79 € Cajas de 200 tiras indicadoras de pH especial L-L625 22 1 caja de 200 tiras de papel indicador Lyphan, pH 3.0 … 5.1 www.labprocess.es 11,17 € pH Electrodos selectivos de iones /6&7"5&$/0-0(¶"%&/"/056#04%&$"3#0/0 640.«4'«$*-.":03%63"$*»/:.&/03$045& t$PNCJOBEPTJOUFHSBFMFMFDUSPEPTFMFDUJWPSFGFSFODJB t/POFDFTJUBOEJTPMVDJPOFT*4" t1VFEFONFEJSFODVBMRVJFSQPTJDJØO t6UJMJ[BDJØOUBOUPFOMBCPSBUPSJPDPNPFODBNQP -BQSFTFODJBEFQBSUÓDVMBTTØMJEBTFOTVTQFOTJØOZMBTEJTPMVDJPOFTUVSCJBT OPJOþVZFOFOMBNFEJEBEFMTFOTPS*OTFOTJCMFTBMBMV[BMPYÓHFOPZB FTQFDJFTSFEPY Especificaciones t%JÈNFUSP NN t-POHJUVE NN t-POHJUVEDBCMF N t$POFDUPS #/$ t7PMVNFONÓOJNPEFNVFTUSBNM t$VFSQPEFQMÈTUJDP /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT1MBUB"H Q)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT#SPNVSP#S &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT$BMDJP$B &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT$MPSVSP$M &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT1FSDMPSBUP$M0 &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT$PCSF$V &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT'MVPSVSP' &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT*PEVSP* &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT1PUBTJP, &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT-JUJP-J &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT.BHOFTJP.H &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT4PEJP/B &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT"NPOJP/) &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT/JUSJUP/0 &TDBMBBNHMQ)B é /5$ &MFDUSPEPTFMFDUJWP$PNCJOBEPJPOFT/JUSBUP/0 &TDBMBBNHMQ)B é Disoluciones patrón para ión selectivo 1BSBTPMJDJUBSMBTTVTUJUVZBMB9999QPSMBSFGFSFODJBEFMJØORVFEFTFB NT-XXXX-10000P Solución de calibración 10.000 ppm iones - 100 ml 30 € NT- XXXX-1000P Solución de calibración 1.000 ppm iones - 100 ml 30 € NT- XXXX-100P Solución de calibración 100 ppm iones - 100 ml 30 € NT- XXXX-10P Solución de calibración 10 ppm iones - 100 ml 30 € NT- XXXX-1P Solución de calibración 1 ppm iones - 100 ml 30 € NT- XXXX-1M Solución de calibración 1 M iones - 100 ml 30 € NT- XXXX-01M Solución de calibración 0,1 M iones - 100 ml 30 € NT- XXXX-001M Solución de calibración 0,01 M iones - 100 ml 30 € NT- XXXX-0001M /5'5*4"# Solución de calibración 0,001 M iones - 100 ml Solución reguladora de pH y desacomplejante del Fl, TISAB - 250 ml 30 € 70 € * Patrón ion de plata a consultar. www.labprocess.es 23 pH Iónometros t-JHFSPTEFEJNFOTJPOFTSFEVDJEBTZUPUBMNFOUFQPSUÈUJMFT t'VODJPOBONFEJBOUFVOJOUVJUJWPTPGUXBSFQBSB1$ t.FEJEBTQVOUVBMFTPNPOJUPSJ[BDJØOFODPOUJOVP t(SÈýDPTJOUFSBDUJWPT t.FEJEBTFONHMNNPMM t(FOFSBDJØOBVUPNÈUJDBBSDIJWPT t*OGPSNBDJØOEFTVTBOÈMJTJTFOGPSNBUPIPKBEFDÈMDVMP&YDFM 3BOHPEFNFEJEB BN7 3FTPMVDJØO N7 "MJNFOUBDJØO .JOJ64#"# TFBMJNFOUBBUSBWÏTEFM1$ *NQFEBODJBEFFOUSBEB FPINT 5FNQFSBUVSBEFUSBCBKP $ $POFYJØOFMFDUSPEP $POFYJØOB1$ #/$ .JOJ64#"# /5*0//5 Ion-meter, Ionómetro de 1 canal, incluye software para PC é /5*0//5 Ion-meter, Ionómetro de 2 canaes, incluye software para PC é /5*0//5 Ion-meter, multi-parámetro. 4 canales de medida (4 BCN). Sin sonda. Alimentación y conexión a PC mediante cable mini-USB (AB) é /5*0//5 Ion-meter, multi-parámetro. 8 canales de medida (8 BCN). Sin sonda. Alimentación y conexión a PC mediante cable mini-USB (AB) é Iónometros multi-parámetro /5TFBEFMBOUBBMPTFRVJQPTDPOWFODJPOBMFTVUJMJ[BOEPMBÞMUJNB UFDOPMPHÓBFODPNVOJDBDJPOFTNFEJBOUFEJTQPTJUJWPTCMVFUPPUI"OESPJE ZBQSPWFDIBOEPMBUFDOPMPHÓBEFMBTPOEBNVMUJJØO t$PODFQUPNPEVMBSMBUBCMFUBFTVOBQMBUBGPSNBJOEFQFOEJFOUFEFMFRVJQP EFMFDUVSBRVFFNQMFBMBDPNVOJDBDJØOCMVFUPPUIQBSBPCUFOFSMPTSFHJTUSPT EFMBTPOEBNVMUJJØOPEFMFMFDUSPEP t-JHFSPTEFEJNFOTJPOFTSFEVDJEBTZUPUBMNFOUFQPSUÈUJMFTHSBDJBTBTV CBUFSÓBEFJØOMJUJPEFMBSHBEVSBDJØO t1FSNJUFMBNFEJEBEFIBTUBTFOTPSFTTJNVMUÈOFBNFOUF t1BSBDPOFYJØOB1$Z5BCMFJODMVJEB 1BSBDPOFYJØOB1$Z5BCMFU /5*0//5#*. 7 canales de medida + ºC, conector para sonda multi-ión + BNC. Sin sonda (a utilizar sonda multi-ión). Alimentación 220V y batería Li-Ion. Bluetooth. Conexión a PC mediante cable mini-USB (AB) o mediante bluetooth. Incluye aplicación Android /55". Tableta de 7” configurada para aplicación Android é Ion-meter multi-parámetro. Hasta 7 canales de medida + ºC, conector multipin + BNC. Sin sonda (a utilizar sonda multi-ión a elegir). Alimentación y conexión a PC mediante cable mini-USB (AB) é é 1BSBDPOFYJØOB1$ /5*0//59 ESPECIFICACIONES $BOBMFTEFNFEJEB NT-ION-NTX NT-ION-NTB-1M DBOBMFT5B DBOBMFT5B 3BOHPEFNFEJEB BN7 3FTPMVDJØO N7 *NQFEBODJBEFFOUSBEB FPINT 5FNQFSBUVSBEFUSBCBKP $ $POFYJØOFMFDUSPEP .VMUJQJONBDIP#/$ $POFYJØOB1$ .JOJ64#"# .BUFSJBMEFMBDBKB "#4 %JNFOTJPOFT 1FTP "MJNFOUBDJØO 24 www.labprocess.es YYNN H H .JOJ64#"# TFBMJNFOUBBUSBWÏTEFM1$ 64#7 pH Sonda Multi-ión -BTPOEBNVMUJJØOFTVOTJTUFNBEFBOÈMJTJTNPEVMBSRVFQFSNJUFDFSUJýDBSTJNVMUÈOFBNFOUFMBDPODFOUSBDJØO EFEJGFSFOUFTJPOFTFOVOBNJTNBNVFTUSB&TUFJOOPWBEPSDPODFQUPQFSNJUFIBDFSSFBMJEBEMBNFEJEBNVMUJQBSB NÏUSJDBEFJPOFTTJNVMUÈOFBNFOUF 6OQSPEVDUPRVFPGSFDFVOBTPMVDJØOTJNQMFFýDB[ZSÈQJEBRVFQFSNJUFBIPSSBSFOSFBDUJWPTZUJFNQPEFBOÈMJTJT -BTPOEB.VMUJJØOQVFEFDPOýHVSBSTFQBSBBOBMJ[BSEFTEFIBTUBEJGFSFOUFTJPOFTFOVONJTNPEJÈNFUSPEF UBOTØMPNN Nuevo concepto de análisis multiparamétrico &MFDUSPEPTNPEVMBSFT 3FDBNCJPEFFMFDUSPEPTFOTFHVOEPTQPSFMVTVBSJP -JTUPQBSBVTBSTJOQBTPTQSFWJPT 1PTJCJMJEBEEFDBMJCSBDJØOTJNVMUÈOFBEFUPEPTMPTJPOFT 4JONBOUFOJNJFOUP .ÓOJNPDPOTVNPEFNVFTUSBNM 6TPUBOUPFODBNQPDPNPFOMBCPSBUPSJP t%JÈNFUSPNN t-POHJUVENN t.BUFSJBMEFMDVFSQP1MÈTUJDP t$POFYJØO.VMUJQJOIFNCSB t7PMVNFONJONVFTUSBNM t4POEBEFUFNQFSBUVSB1UJODMVJEB Uso con el Ionómetro NT-ION-NTB-IM y NT-ION-NTX Electrodos indicadores micro, para inserción en sonda Multi-ión, recambiables /5B256-H Cabezal modular portaelectrodo (hasta 6 electrodos indicadores + 1 referencia) 310 € /5AG-MD107 Plata (Ag+) 180 € /5BR-MD080 Bromo (Br-) 180 € /5CA-MD040 Calcio (Ca2+) 180 € /5CL-MD035 Cloruro (Cl-) 180 € /5CLO4-MD099 Perclorato (ClO4-) 335 € /5CU-MD064 Cobre (Cu2+) 335 € /5I-MD127 Ioduro (I-) 335 € /5K-MD039 Potasio (K+) 180 € /5LI-MD007 Litio (Li+) 335 € /5MG-MD024 Magnesio (Mg2+) 335 € /5NA-MD023 Sodio (Na+) 335 € /5NH4-MD018 Amonio (NH4+) 180 € /5NO2-MD046 Nitrito (NO2-) 335 € /5NO3-MD062 Nitrato (NO3-) 180 € /5ER-MDRX11 Electrodo de referencia universal modular 180 € /5-SC-MI-A Juego de disoluciones de calibración Multi-Ión 3x250 ml + disolución de acondicionamiento 107 € /5SC--MI Juego de disoluciones de calibración Multi-Ión 3x250 ml Disoluciones de calibración 80 € www.labprocess.es 25 $& Conductímetros de bolsillo serie 5 &-'65630%&-".07*-*%"%&/464."/04 /VODBBOUFTDPOFTUBTFYUSBPSEJOBSJBTFTQFDJýDBDJPOFT t 1BOUBMMBSFUSPJMVNJOBEBEFDPMPSFTB[VMQBSBNFEJEBWFSEFQBSBDBMJCSBDJØOZSPKBQBSBBMBSNB t/POFDFTJUBSÈOBEBNÈTDPOQBUSPOFTQJMBTQBQFMUJTÞZWBTPEFDBMJCSBDJØO t3FDPNFOEBEPTQBSBNFEJEBTFOBHSJDVMUVSBBHVBTKBSEJOFSÓBIJESPQØOJDBBDVJDVMUVSB QJTDJOBTZ41"4UPSSFTEFSFGSJHFSBDJØOFEVDBDJØO t$PODÏMVMBSFFNQMB[BCMF ESPECIFICACIONES CONDT 5 $POEVDUJWJEBEFTDBMB yç4yç4yN4 3FTPMVDJØO &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMWBMPSNFEJEP Sí *OEJDBDJØOEFFTUBCJMJEBEEFNFEJEB Sí "MBSNBEFMFTUBEPEFMBDÏMVMB 5BNQPOFTSFDPOPDJEPT y 1BUSPOFTSFDPOPDJEPT ç4N4 Sí *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO 5$DPFýDJFOUFEFUFNQFSBUVSB y$ 53UFNQFSBUVSBEFSFGFSFODJB $ 5%4FTDBMB QQNQQUHM 5%4'BDUPS y 3FTPMVDJØO EFMWBMPSMFÓEP 4BMJOJEBEFTDBMB QQUHM 5FNQFSBUVSBFTDBMB$ y 3FTPMVDJØO1SFDJTJØO ¡$ "VUPBQBHBEP "MPTNJOUSBTQVMTBSVOBUFDMB 1BOUBMMB -$%%VBMSFUSPJMVNJOBEBBDPMPSFT 1SPUFDDJØO*1 *1 "MJNFOUBDJØO Y7"""QJMBT 7JEBEFMBTCBUFSÓBT IPSBT %JNFOTJPOFT Y 1FTP H (BSBOUJBJOTUSVNFOUPDÏMVMB B×PTNFTFT ($0/%5 COND 5 Tester, completo con instrumento y célula, 1 cap para calibración, disoluciones patrón 1413 μS + 12.88 mS (botellas de 55 ml), cinta de transporte, papel tisú, 4 baterías y maleta é ($0/%5&$0 COND 5 Tester, sin maleta ni disoluciones é Accesorios G-RCONDT5 Célula de recambio para COND 5 Tester 40 € Ver disoluciones patrón en página xxx Pantallas Detalles vaso de calibración 26 www.labprocess.es Cinta soporte $& Conductimetro de bolsillo Tester 1 -"&$0/0.*"&/46#0-4*--0 -JTUPTQBSBTVVTPOPOFDFTJUBSÈOBEBNÈTDPOQBUSPOFTEFDPOEVDUJWJEBEQBQFMUJTÞ ZWBTPEFDBMJCSBDJØO t"NQMJBQBOUBMMBDPOJOEJDBDJØOEFMPTQBUSPOFTVUJMJ[BEPTFOMBDBMJCSBDJØO t*OEJDBEPSEFFTUBCJMJEBEEFNFEJEB t$PNQFOTBDJØOEFUFNQFSBUVSBB$ t$BMJCSBDJØOFOQVOUPT t-BSHBWJEBEFGVODJPOBNJFOUPDPOQJMBTFTUÈOEBSEF7DPNQBUJCMFTDPOQJMBTSFDBSHBCMFT t4FOTPSýKPOPSFFNQMB[BCMF %FFMFDDJØOFOBHSJDVMUVSBKBSEJOFSÓBIJESPQØOJDBBDVJDVMUVSBQJTDJOBTZ41"4 ESPECIFICACIONES $POEVDUJWJEBEFTDBMB 3FTPMVDJØO TESTER CONDT 1 yç4yN4 &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMWBMPSNFEJEP 1VOUPTEFDBMJCSBDJØO 5BNQPOFTSFDPOPDJEPT B 4ZN4 *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO Sí *OEJDBDJØOEFFTUBCJMJEBEEFNFEJEB Sí "MBSNBEFMFTUBEPEFMFMFDUSPEP 535FNQFSBUVSBEFSFGFSFODJB &TDBMB5%4 Sí $ QQNQQUHM 'BDUPS5%4 y "VUPBQBHBEP "MPTNJOUSBTQVMTBSVOBUFDMB 1BOUBMMB -$% 1SPUFDDJØO*1 *1 "MJNFOUBDJØO Y7"""QJMBT 7JEBEFMBTCBUFSÓBT IPSBT %JNFOTJPOFT YNN 1FTP H (BSBOUJBJOTUSVNFOUPDÏMVMB B×PNFTFT ($0/%5 COND 1 Tester, completo con 1 cap para calibración, disoluciones patrón 1413 μS y 12.88 mS (botellas de 55 ml) cinta de transporte, papel tisú, 4 baterías y maleta é ($0/%5&$0 COND 1 Tester, sin maleta ni disoluciones é RECUERDE 1 ppt = 1 g/l = 1000 ppm Como se envia www.labprocess.es 27 $& Conductímetros portátiles Knick Portavo /6/$"6/%*4&º0--&(»"&4504/*7&-&4 t%PCMFGVODJØOQPSUÈUJMZTPCSFNFTB t3FDPNFOEBEPQBSBNFEJEBFOBHVBTQVSBTFJOEVTUSJBGBSNBDÏVUJDB t*EFBMQBSBMBCPSBUPSJPZBOÈMJTJTEFQSPDFTPT t$BSDBTBEFQMÈTUJDPSFTJTUFOUFQBSBFOUPSOPTJOEVTUSJBMFTBEWFSTPT t1PSUBTFOTPSJOUFHSBEP t$VCJFSUBQSPUFDUPSBJOUFHSBEBQSPUFHFMBQBOUBMMBZTFEPCMBQBSBGPSNBSVOTPQPSUFEF NFTB t&MZDPOEBUBMPHHFSZDPOFYJØOBJNQSFTPSBP1$ tÁOJDPVUJMJ[BDÏMVMBTDPOWFODJPOBMFTZUBNCJÏO.FNPTFOTEJHJUBMFT Y con versiones ATEX, los únicos! (opcional) ,1$0/ $POEVDUÓNFUSPQPSUÈUJM1035"70QBSBDÏMVMBTFTUBOEBSZ.FNPTFOTNBMFUBDÏMVMB$"54,ZEJTPMVDJPOFT é ,1$0/ $POEVDUÓNFUSPQPSUÈUJM1035"70QBSBDÏMVMBTFTUBOEBSZ.FNPTFOTNBMFUBZEJTPMVDJPOFT4*/$²-6-" é ,1$0/ $POEVDUÓNFUSPQPSUÈUJM1035"70QBSBDÏMVMBTFTUBOEBSZ.FNPTFOTNBMFUBDÏMVMB$"54,ZEJTPMVDJPOFT é ,1$0/ $POEVDUÓNFUSPQPSUÈUJM1035"70QBSBDÏMVMBTFTUBOEBSZ.FNPTFOTNBMFUBZEJTPMVDJPOFT4*/$²-6-" é ,1$0/9 $POEVDUÓNFUSPQPSUÈUJM1035"70"5&9QBSBDÏMVMBTFTUBOEBSZ.FNPTFOTNBMFUBZEJTPMVDJPOFTQ)4*/$²-6-" é Células de conductividad para CON KNICK SK-900 Célula de conductividad de 4 polos de grafito, cuerpo de plástico, K=0.475 (1μS…500 mS) -5…80ºC, CAT NTC30K y 1 m cable 295 € KP-SE202 Célula de conductividad KNICK de 2 polos, cuerpo de inoxidable para AGUAS PURAS, K=0.1 (0,01...199.9 uS/cm) -5…100ºC 603 € KP-SE204 Célula de conductividad KNICK de 4 polos de grafito, cuerpo de plástico, K=0.475 (1μS…500 mS) -5…100ºC, CAT NTC30K y 1 m cable 489 € KP-SE615/1MS Célula de conductividad KNICK de 2 polos de grafito, digital MEMOSENS, cuerpo de plástico, K=1 (10μS…20 mS) -5…80ºC, sin cable 326 € KP-CA / MS-001XFA-L Cable para sensores Memosens, L=1.5m 221 € Accesorios para conductímetros KNICK KP-ZU0284 Cámara de flujo de vidrio Pyrex para células de conductividad G-50000112 Soporte articulado para 4 sensores más base ZU-0289 Adaptador de entrada de 8 polos a 2 bananas diámetro 4 mm. Conductímetro &TDBMBDPOEVDUJWJEBE 237 € 70 € 110 € COND 7 COND 70 ç4DN N4DN ç4 N4 PORTAVO 902 &TDBMBTBMJOJEBE HLH¡$ &TDBMB5%4 5FNQFSBUVSB$ $PNQFOTBDJØOEFUFNQFSBUVSBNBOVBMZBVUPNÈUJDB yHSM y NHM¡$ y y "VUPNÈUJDB/5$,û "VUPNÈUJDB/5$L1U 5$DPFýDJFOUFEFUFNQFSBUVSB y¡$ -JOFBMy¡$QBSBBHVBTVMUSBQVSBT ZBHVBTOBUVSBMFTTFHÞO&/ 53UFNQFSBUVSBEFSFGFSFODJB y¡$ $ ç4oç4oN4oN4 4DN FOUSBEBEFDPOTUBOUF PVOWBMPSDVBMRVJFSB QPMPT ØQPMPT 1VOUPTEFDBMJCSBDJØODPOSFDPOPDJNJFOUP BVUPNÈUJDP $ÏMVMBT %BUBMPHHJOH 1BOUBMMB 4ÓSFMPKUJFNQPSFBM %JNFOTJPOFTNNZ1FTPH www.labprocess.es 64# Sí QJMBT""" 1SPUFDDJØOEFFYQMPTJØOTØMPNPEFMPT"5&9 &TUBORVFJEBE 1BOUBMMBEFTFHNFOUPT 64# "VUPBQBHBEP 7JEBEFMBTCBUFSÓBT 4ÓSFMPKUJFNQPSFBM -$% $POFYJØOB1$ "MJNFOUBDJØO SFHJTUSPT NBOVBM BJOUFSWBMPTB NJO PQPSFWFOUPT .BO"VUPEBUPTDPO GFDIBZIPSB (-1 28 PORTAVO 904 ç4DNyN4DN TFHÞONPEFMPEFTFOTPS QJMBT"""BEBQUBEPSDPSSJFOUF64# 4ØMPNPEFMPT"5&9DPOTVMUBS IPSBT IPSBT *1 *1 YY YY $& Conductímetro portátil COND 7 4&/$*--0%63"%&30:&$0/».*$0 t$BMJCSBDJØOBVUPNÈUJDBEFBQVOUPTBFTDPHFSFOUSBWBMPSFT FTUÈOEBSZDBMJCSBDJØONBOVBMFOQVOUPEFýOJEPQPSFMVTVBSJP t1BOUBMMBDPOJOEJDBDJØOEFDPOEVDUJWJEBEZ$ t1SPUFHJEPDPOGVOEBEFHPNBSPCVTUB t$PONBMFUBDÏMVMBEFDPOEVDUJWJEBEDPOTFOTPS$ZEJTPMVDJPOFT QBUSØO t53FOUSFy¡$Z5$FOUSFy t&TUBODP*1 ($0/ $POEVDUÓNFUSPQPSUÈUJM94$0/%DPNQMFUPDPONBMFUBGVOEBEFHPNBEJTPMVDJPOFTQBUSØODÏMVMBDPO$"5(5 ZNBOVBMFTQB×PM é ($0/ $POEVDUÓNFUSPQPSUÈUJM94$0/%DPNQMFUPDPONBMFUBGVOEBEFHPNBEJTPMVDJPOFTQBUSØOZNBOVBMFTQB×PM4*/ $²-6-" é &4"-5 4BMJOPNFUSPQPSUÈUJMQQU DPODÏMVMB é Conductímetro portátil COND 70 6/%&4$6#3*.*&/50/6/$"5"/501035"/10$0 t(-1EBUBMPHHFSDPONFNPSJBTZTBMJEBEFEBUPTEJSFDUBNFEJBOUF64# t1BOUBMMBSFUSPJMVNJOBEBDPOJOEJDBDJØOEF Ì.FEJEBEFDPOEVDUJWJEBEZ5%4Ì5FNQFSBUVSBÌ'FDIBZIPSB Ì1BUSPOFTVUJMJ[BEPTFOMBDBMJCSBDJØOÌ$PNQFOTBDJØOEFUFNQFSBUVSB.5$P"5$ t$BMJCSBDJØOIBTUBQVOUPTDVTUPN t$"-5*.&3QSPHSBNBDJØOEFMBGSFDVFODJBEFDBMJCSBEP t$PONBMFUBGVOEBEFHPNBQBSBFMDPOEVDUÓNFUSPDÏMVMBEFDPOEVDUJWJEBEDPO TFOTPS$EJTPMVDJPOFTQBUSØOZWBTPEFQMÈTUJDP Y software gratis ($0/ $POEVDUÓNFUSPQPSUÈUJM94$0/%DPNQMFUPDPONBMFUBGVOEBEFHPNBEJTPMVDJPOFTQBUSØODÏMVMBDPO$"5(5 ZNBOVBMFTQB×PM ($0/ $POEVDUÓNFUSPQPSUÈUJM94$0/%DPNQMFUPDPONBMFUBGVOEBEFHPNBEJTPMVDJPOFTQBUSØOZNBOVBMFTQB×PM4*/ $²-6-" é é Células de conductividad para COND 7 y COND 70 XS G-2301T Célula de conductividad de 2 polos, K=1 (10μS…200 mS) 0…80ºC, CAT NTC30K, de plástico y 1 m cable. (Low Cost) SK-51/1 Célula de conductividad de 2 polos, K=1 (10μS…200 mS) 0…80ºC, CAT NTC30K, de vidrio y 1 m cable 185 € SK-51/01 Célula de conductividad con sonda temperatura, K=0,1 (0,1 μS…1mS) CAT NTC30K, de plástico y acero inox, 1 m cable 185 € E-ST17 Célula de conductividad ST6, K=1 (10 μS…150mS) 0…80ºC, CAT NTC30K, de plástico y 1 m cable, y protector extraible para limpieza, de elección para medios sucios 196 € 110 € Células de conductividad para CON 6+ E-ST6 Célula de conductividad ST6 de 2 polos, K=1 (10μS…150 mS) 0…80ºC, CAT NTC30K, de plástico y 1 m cable 186 € SK-6/01 Célula de conductividad SK-252-10 de 2 polos, K=0.1 (0…150 μS) 0…80ºC, CAT NTC30K, de inoxidable y 1 m cable 200 € HY-3032 Célula de conductividad 3032 para penetración en suelos, K=1, 0…50ºC, CAT NTC30K, de inoxidable y 1 m cable 205 € G2301T-6 Célula de conductividad de 2 polos, K=1 (10μS…200 mS) 0…80ºC, CAT NTC30K, de plástico y 1 m cable 120 € www.labprocess.es 29 $& Conductímetro de sobremesa COND 80 &"4:&4&-"%+&5*70%&-/6&704*45&." tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:1BOUBMMBBUPEPDPMPSJMVNJOBEBDPOUPEBMBJOGPSNBDJØOQBUSPOFTVUJMJ[BEPTFTUBCJMJEBEUFNQFSBUVSBGFDIBZIPSB DÏMVMBVUJMJ[BEB64#P1$DPOFDUBEPOPNCSFEFVTVBSJPZEFMBNVFTUSB tEasy to learn:.BOVBMFOQBOUBMMBFOFTQB×PMPUSPTJEJPNBT tEasy to calíbrate:3FDPOPDJNJFOUPBVUPNÈUJDPEFQBUSPOFTZBVUPEJBHOPTUJDPEFMBDÏMVMB t%PDVNFOUBDJØODPNQMFUB(-1 t/BEBPQDJPOBMUPEPJODMVJEPIBTUBFMTPGUXBSFZDBCMF t"HJUBEPSNBHOÏUJDPTFQBSBCMFEFGPSNBGÈDJMZPQFSBCMFTJOFOUSBSFOFMTPGUXBSF t4PQPSUFQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT ESPECIFICACIONES COND 80 N4 Escala de Conductividad 3FTPMVDJØO &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMBMFDUVSBMFÓEB NHMHSM Escala TDS 'BDUPS5%4 y 1SFDJTJØO EFMBMFDUVSBMFÓEB QQUHM Escala Salinidad 1SFDJTJØO .û Escala Resistividad 1SFDJTJØO EFMBMFDUVSBMFÓEB y Escala Temperatura ºC 1SFDJTJØO ¡$ 6OJEBE ¡$¡' .BOVBMPBVUPNÈUJDB/5$,û ¡$ 5FNQFSBUVSBDPNQFOTBDJØO Sí 5FNQFSBUVSBDBMJCSBDJØO 1VOUPTEFDBMJCSBDJØODPOEVDUJWJEBE 4N4 QVOUPEFýOJEPQPSFMVTVBSJP 1BUSPOFTSFDPOPDJEPT Sí *OEJDBDJØOEFDBMJCSBDJØOFTUÈOEBS 5$DPFýDJFOUFEFUFNQFSBUVSB y$ 53UFNQFSBUVSBEFSFGFSFODJB y$ (-1DBMJCSBDJØO 4*DPOGFDIBZIPSB *OEJDBDJØOEFFTUBEPEFMBDÏMVMB 4*DPOJDPOP Sí $"-%6&DPOBMBSNB 5JQPEFDÏMVMB ØQPMPT $POTUBOUFEFDÏMVMB y Sí 4JTUFNB(-1 ."/"650EBUPTDPOGFDIB ZIPSB .FNPSJB 1BTTXPSE /PýKP 1BOUBMMB .BUSJYNVMUJDPMPSDPOJDPOPTEJHJUBM &OUSBEBT #/$+BDLQIPOP"5$ 64#QBSB QSJOUFS P1$64#QBSBUFDMBEPFYUFSOP *EJPNBT JEJPNBT Sí .BOVBM0OMJOF Sí "HJUBEPSNBHOÏUJDP $POUSPMEFWFMPDJEBEEFMBHJUBEPS 1SPUFDDJØO*1 *1 "MJNFOUBDJØO "$%$BEBQUBEPS7 %JNFOTJPOFT YYNN 1FTP 30 SQN HS ($0/% $POEVDUJNFUSPEFTPCSFNFTB$0/%94DPNQMFUPDPOBHJUBEPSNBHOFUJDPDÏMVMBEFDPOEVDUJWJEBEEFWJESJPDPO TFOTPSEFUFNQFSBUVSBEJTPMVDJPOFTQBUSØO4DNZNBOVBM é ($0/% $POEVDUJNFUSPEFTPCSFNFTB$0/%94DPNQMFUPDPOBHJUBEPSNÈHOFUJDPEJTPMVDJPOFTQBUSØO4DN ZNBOVBM4*/$²-6-"Versión para que Ud. elija la célula adecuada a su necesidad é www.labprocess.es $& Conductímetro de sobremesa COND 8 &"4:&4&-"%+&5*70%&-/6&704*45&." tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:&OQBOUBMMBEFDPMPSFTDPOPDFSÈDPORVFQBUSPOFTTFIBDBMJCSBEPMBFTUBCJMJEBEEFMFDUVSBMBUFNQFSBUVSBZFM FTUBEPEFMBDÏMVMB tEasy to calíbrate:3FDPOPDJNJFOUPBVUPNÈUJDPEFQBUSPOFTDPOJDPOPEFBVUPEJBHOPTUJDP t"HJUBEPSNBHOÏUJDPPQDJPOBMTFQBSBCMFEFGPSNBGÈDJMZVUJMJ[BCMFTJOOFDFTJEBEEFFOUSBSFOFMTPGUXBSF t4PQPSUFQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT ESPECIFICACIONES Escala de Conductividad 3FTPMVDJØO C0ND 8 BASIC / STIRRER N4 &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMBMFDUVSBMFÓEB NHMHSM Escala TDS 'BDUPS5%4 y 1SFDJTJØO EFMBMFDUVSBMFÓEB Escala Temperatura ºC 1SFDJTJØO y ¡$ 6OJEBE ¡$¡' 5FNQFSBUVSBDPNQFOTBDJØO 5FNQFSBUVSBDBMJCSBDJØO 1VOUPTEFDBMJCSBDJØODPOEVDUJWJEBE .BOVBMPBVUPNÈUJDB/5$ ,û ¡$ Sí 4N4 QVOUPEFýOJEPQPSFMVTVBSJP 1BUSPOFTSFDPOPDJEPT *OEJDBDJØOEFDBMJCSBDJØOFTUÈOEBS 4* 5$DPFýDJFOUFEFUFNQFSBUVSB y$ 53UFNQFSBUVSBEFSFGFSFODJB y$ *OEJDBDJØOEFFTUBEPEFMBDÏMVMB 5JQPEFDÏMVMB Sí QPMPT $POTUBOUFEFDÏMVMB 1BOUBMMB .BUSJYDPMPSFT &OUSBEBT #/$+BDLQIPOP"5$ "HJUBEPSNBHOÏUJDP /0FOWFSTJØOCÈTJDB $POUSPMEFWFMPDJEBEEFMBHJUBEPS SQN 1SPUFDDJØO*1 *1 "MJNFOUBDJØO "$%$BEBQUBEPS7 %JNFOTJPOFT YYNNTPMPJOTUSV NFOUPYYNNDPO BHJUBEPS HSTJOBHJUBEPSHSDPO BHJUBEPS 1FTP ($0/%" $POEVDUJNFUSPEFTPCSFNFTB$0/%94BHJUBEPSNBHOÏUJDPDPNQMFUPDPODÏMVMBEFDPOEVDUJWJEBEWJESJPZ1UDPO TFOTPSEFUFNQFSBUVSBEJTPMVDJPOFTQBUSØO4DNZNBOVBM é ($0/%" $POEVDUJNFUSPEFTPCSFNFTB$0/%94DPNQMFUPDPOBHJUBEPSNBHOÏUJDPEJTPMVDJPOFTQBUSØO4DN ZNBOVBM4*/$&-Á-"Versión para que Ud. elija la célula adecuada a su necesidad é ($0/% $POEVDUJNFUSPEFTPCSFNFTB$0/%94DPNQMFUPDPODÏMVMBEFDPOEVDUJWJEBE(5EFQMÈTUJDPDPOTFOTPSEF UFNQFSBUVSB-PX$PTU EJTPMVDJPOFTQBUSØO4DNZNBOVBM4*/"(*5"%03 é ($0/% $POEVDUJNFUSPEFTPCSFNFTB$0/%94DPNQMFUPDPOEJTPMVDJPOFTQBUSØO4DNZNBOVBM 4*/$&-Á-"/*"(*5"%03 é Ver células en página siguiente. www.labprocess.es 31 $& Conductímetro de sobremesa COND 51 Básico t1BOUBMMB-$%SFUSPJMVNJOBEBDPOJOEJDBDJØOEFDPOEVDUJWJEBEZ$ t:DPOJDPOPEFFTUBEP t&TDBMBN44N4 t4FJODMVZFTPQPSUFBSUJDVMBEPQBSBTFOTPSFT t$BMJCSBDJØOBVUPNÈUJDBFOQVOUPT4N4 t5FNQFSBUVSBEFSFGFSFODJB$ t$PFýDJFOUFEFUFNQFSBUVSB$ t$PFýDJFOUFEFDÏMVMBDN - ($0/ $POEVDUÓNFUSPEFTPCSFNFTB$0/%DPNQMFUPDPOCSB[PBSUJDVMBEPQBSBTFOTPSFTDÏMVMB(5EFFQPYJDPO TFOTPSEFUFNQFSBUVSBEJTPMVDJPOFTQBUSØOZNBOVBMFTQB×PM é ($0/ $POEVDUÓNFUSPEFTPCSFNFTB$0/%DPNQMFUPDPOCSB[PBSUJDVMBEPQBSBTFOTPSFTEJTPMVDJPOFTQBUSØOZNBOVBM FTQB×PM4*/$²-6-"OJ$"5 é Células de conductividad Células para CONDUCTÍMETROS XS G-2301T Célula de uso general. 10 μS/cm…200 mS/cm, 0…80ºC, cuerpo de epoxi y 1m de cable SK-51/1 Célula de uso general. 10 μS/cm…150 mS/cm, 0…80ºC, cuerpo de vidrio y platino con 1m de cable. Con sonda CAT NTC30k 140 € SK-51/01 Célula de uso general. 0.1…500 μS/cm, 0…80ºC, cuerpo de epoxi e inox y 1m de cable. Con sonda CAT NTC30k 200 € 110 € Células para CON BASIC y ADVANCED (EUTECH) E- ST10 Célula de conductividad de 2 polos, K = 1 (10 μS…150 mS), 0…80ºC, cuerpo de plástico ULTEM y células de inox, con sonda CAT NTC 30K integrada y 1 m de cable con conector 8-Pin DIN. Medidas 144x 16 mm. 196 € E-ST11 Célula de conductividad de 4 polos, K=0.530 (10 μS…200 μS) 0…80ºC, cuerpo de epoxi y células de grafito, con sonda CAT NTC 30K integrada y 1 m de cable con conector 8-Pin DIN 305 € SK700/1 Célula de conductividad de 2 polos, K = 1 (1 μS…150 μS), 0…80ºC, cuerpo de vidrio y células de platino, con sonda CAT NTC 30K integrada y 1 m de cable con conector 8-Pin DIN. Medidas 120 x 12 mm. 185 € SK700/01 Célula de conductividad de 2 polos, K = 0.1 (0.1 μS…500 μS), 0…80ºC, cuerpo de vidrio y células de platino, con sonda CAT NTC 30K integrada y 1 m de cable con conector 8-Pin DIN. Medidas 120 x 12 mm. 267 € Accesorios G-STIRRER Agitador magnético para serie 8 y 80, controlado por el instrumento G-TECLADO Teclado externo para serie 80 30 € G-PRINTER Impresora USB para serie 80 220 € 170 € Certificado de calibración de Conductímetros 4FVUJMJ[BFOMBDFSUJýDBDJØOMBTEJTPMVDJPOFTQBUSØO)".*-50/DVZPTMPUFTFTUÈODFSUJýDBEPTQPSFM%'.%BOJTI/BUJPOBM.FUSPMPHZ*OTUJ UVUF BDSFEJUBEP%"/",%BOJTI"DDSFEJUBUJPOBOE.FUSPMPHZ'VOE SFDPOPDJEPFOUSFMPTJOTUJUVUPTFVSPQFPTEFQSFTUJHJPJODMVJEP&/"$ 5BNCJÏOTFVUJMJ[BOMPTDPSSFTQPOEJFOUFTTJNVMBEPSFTEFUFNQFSBUVSBZDPOEVDUJWJEBEDFSUJýDBEPT &OFMDFSUJýDBEPTFSFQSFTFOUBOMPTWBMPSFTPCUFOJEPTFOMBDBMJCSBDJØOEFMJOTUSVNFOUPJODFSUJEVNCSFUSB[BCJMJEBE QSPDFEJNJFOUPDPOEJDJPOFTQBUSPOFTVUJMJ[BEPTFUD -1 $BMJCSBDJØODPOEVDUJNFUSPEFQPSUÈUJMUSB[BCMF/*45BZ4DN é -1 $BMJCSBDJØODPOEVDUJNFUSPEFTPCSFNFTBUSB[BCMF/*45BZ4DN é Otros valores de calibración, bajo demanda 32 www.labprocess.es $& Disoluciones Patrón de Conductividad tCertificadasQPSFM*OTUJUVUP%BOÏTEF.FUSPMPHÓB 'VOEBNFOUBM%'. &/"$ t4FJODMVZFFMDFSUJýDBEPFODBEBCPUFMMB (SBDJBTBMWBTPJOUFHSBEPFOMBCPUFMMB t&WJUBSÈMBDPOUBNJOBDJØO t&MJNJOBFMUSBOTWBTFBPUSPTSFDJQJFOUFT t"IPSSPNFOPTDBOUJEBEEFQBUSØOVUJMJ[BEB t$FSUJýDBEPEFTDBSHBCMFEFTEFMBXFC XXXMBCQSPDFTTFT t6OBCPUFMMBEFNMFGFDUVBOEPVOBDBMJCSBDJØO EJBSJBUJFOFNFTFTEFEVSBDJØO $PODFSUJýDBEP%'.&/"$ $BEVDJEBENFTFT ) 4DN$ CPUFMMBEFWJESJPYNM$BEVDJEBENFTFT é ) 4DN$ CPUFMMBEFWJESJPYNMTH641 $BEVDJEBENFTFT é ) 4DN$ CPUFMMBEFWJESJPYNM$BEVDJEBENFTFT é ) 4DN$ CPUFMMBEFWJESJPYNM$BEVDJEBENFTFT é ) N4DN$ CPUFMMBEFWJESJPYNM$BEVDJEBENFTFT é ) 4DN$4DN$ CPUFMMBi"VUPDBMwDPOWBTPEFDBMJCSBDJØOJOUFHSBEPYNM$BENFTFT é ) 4DN$4DN$ CPUFMMBi"VUPDBMwDPOWBTPEFDBMJCSBDJØOJOUFHSBEPYNM$BENFTFT é ) 4DN$4DN$ CPUFMMBi"VUPDBMwDPOWBTPEFDBMJCSBDJØOJOUFHSBEPYNM$BENFTFT é ) 4DN$4DN$ CPUFMMBi"VUPDBMwDPOWBTPEFDBMJCSBDJØOJOUFHSBEPYNM$BENFTFT é Disoluciones patrón ( %JTPMVDJØOQBUSØOEFDPOEVDUJWJEBE4 $ Ø4$ YNM é ( %JTPMVDJØOQBUSØOEFDPOEVDUJWJEBE4 $ Ø4$ YNM é ( %JTPMVDJØOQBUSØOEFDPOEVDUJWJEBEN4 $ ØN4$ YNM é %*40-6$*0/&41"53»/%&$0/%6$5*7*%"%1&26&º070-6.&/ ( %JTPMVDJØOQBUSØOEFDPOEVDUJWJEBE4$ YNM é ( %JTPMVDJØOQBUSØOEFDPOEVDUJWJEBEN4DN$ YNM é www.labprocess.es 33 $& Disoluciones patrón de conductividad REAGECON 1&%*%0#"+0%&."/%" t4FJODMVZFFMDFSUJýDBEPFODBEBCPUFMMB 7BMPSFTFTQFDJBMFTQFEJEPCBKPEFNBOEB %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. 4VTUJUVJEBQPSMB)BNJMUPO) 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$ %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$DFSUJýDBEBDBEVDJEBENFTFTYNM 3$4,$. Otros valores bajo demanda, consulte! Disoluciones patrón de conductividad Reagecon que han sido sustituidas por HAMILTON (Ver precios en página 33) 34 Cat nº REAGECON Cat nº HAMILTON Descripción 3$4,$ ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$ ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4, ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$ ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$4 ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$- ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$ ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ 3$4,$. ) %JTPMVDJØOFTUÈOEBSEFDPOEVDUJWJEBE4DNB$ www.labprocess.es 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € 178 € www.labprocess.es 35 Portavo 907 Knick 1"3"&-&$530%04»15*$04%&0 4FMFQVFEFODPOFDUBSBEFNÈTEFMTFOTPSEF0ØQUJDP TPOEBT.FNPTFOTEFQ)ZDPOEVDUJWJEBE$POQBOUBMMB HSÈýDBFOFTQB×PMBDPMPSSFHJTUSBEPSEFEBUPTCBUFSÓB -JJPOZQVFSUP64# &M1PSUBWPFTJEFBMQBSBMBCPSBUPSJPZBOÈMJTJTEFQSPDFTPT t$BSDBTBEFQMÈTUJDPSFTJTUFOUFQBSBFOUPSOPTJOEVTUSJBMFTBEWFSTPT t1PSUBTFOTPSJOUFHSBEPRVFQSPUFHFDPOUSBMBEFTIJESBUBDJØOTFOTPS t$VCJFSUBQSPUFDUPSBJOUFHSBEBQSPUFHFMBQBOUBMMBZTFEPCMBQBSBGPSNBSVO TPQPSUFEFMBCPSBUPSJP t&MÞOJDPQPSUÈUJM"5&9;POBPQDJPOBM ,109: 1035"70NVMUJQPSUÈUJM,OJDLDPNQMFUPDPONBMFUBNBOVBMFTQB×PMZFMFDUSPEPEF0YJHFOPEJTVFMUP»15*$04& DPONEFDBCMF é ,109: 1035"70NVMUJQPSUÈUJM,OJDLDPNQMFUPDPONBMFUB40'58"3&DBCMF1$ZNBOVBMFTQB×PM4*/4&/403 é Otros modelos, consultar Recambios para PORTAVO de oxígeno disuelto óptico KP-SE340 Electrodo óptico con cable fijo, longitud sensor 150 mm, para Portavo 907 KP-ZU0925 Batería Li-ion (cargable mediante cable USB para Portavo) 965 € 148 € KP-ZU0913 Recambio sensor cap para electrodo O2 óptico Knick SE340 213 € Certificado de calibración de Oxímetros $BMJCSBDJØOBEF0NFEJBOUFJOTFSDJØOFODÈNBSBEFþVKPDPO/JUSPHFOPHBTQBTBOUF EFQVSF[B/0QQN)0QQN$0$0QQN5)$BT$) QQN Z DPOUSPMBEBUFSNJDBNFOUF $BMJCSBDJØOBEF0BMBJSFFODÈNBSBDPOIVNFEBESFMBUJWBBM &OFMDFSUJýDBEPTFSFQSFTFOUBOMPTWBMPSFTPCUFOJEPTFOMBDBMJCSBDJØOEFMJOTUSVNFOUP JODFSUJEVNCSFUSB[BCJMJEBEQSPDFEJNJFOUPDPOEJDJPOFTQBUSPOFTVUJMJ[BEPTFUD LP-51-14 Calibración Oxímetro 170 € &OFTUBFEJDJØOEFDBUÈMPHPIFNPTEFDJEJEPJODPSQPSBSTØMP0YÓNFUSPTØQUJDPTEBEBMBHSBOWFOUBKBEFVTPEFFTUFUJQPEFJOTUSVNFO UPTFODPNQBSBDJØODPOMPTDMÈTJDPTDPOTFOTPSFTEFNFNCSBOBZBTFBOBNQFSPNÏUSJDPTPHBMWÈOJDPT .ÈTSPCVTUPTýBCMFTOPMFTBGFDUBOOJFM$0OJFM)4QPSFKFNQMPOJUBNQPDPOFDFTJUBOVOþVKPNÓOJNPQBSBNFEJSDPNPUBNQPDP DBNCJPEFFMFDUSPMJUPOJNFNCSBOBT 4VNBOUFOJNJFOUPTFCBTBFODBNCJBSFMDBCF[BMØQUJDPVOBWF[BMB×P 1SÈDUJDBNFOUFOPOFDFTJUBODBMJCSBSTF :ýOBMNFOUFFMDPTUFEFNBOUFOJNJFOUPFTNVZJOGFSJPSBMPTDMÈTJDPT0YÓNFUSPT 36 www.labprocess.es Oxímetro DO 450 $0/4&/403»15*$0 t5FDOPMPHÓB3%0ØQUJDBRVFSFEVDFFMUJFNQPEFNBOUFOJNJFOUPTJOFMFDUSPMJUPZTJO NFNCSBOBT t&TUBODP*1BQSVFCBEFBHVBZBQSVFCBEFQPMWP t1BOUBMMBSFUSPJMVNJOBEB t.FEJEBEFTBUVSBDJØOZNHMQQN DPOTØMPQVMTBSVOCPUØO t"MBSNBEFDBMJCSBDJØO t(-1GFDIBZIPSBFOUJFNQPSFBMDPOBMNBDFOBNJFOUPEFIBTUBDPOKVOUPTEFEBUPT tJODMVJEPMPTEFDBMJCSBDJØO t"MJNFOUBDJØOBCBUFSÓBTIPSBTEFEVSBDJØO PDPOBEBQUBEPSEFDPSSJFOUFPQDJPOBM t64#P34DPOTBMJEBEFEBUPTQBSB1$PJNQSFTPSB Oxímetro DO450, completo con maleta, electrodo óptico de oxigeno disuelto con 3 m de cable, sensor cap, cámara de calibración, contrapreso / protector de acero inoxidable, cable USB y manual E-DO450-3 1.495 € Recambios para E-DO450 &3%0. Electrodo óptico OD, con 3 m de cable y sensor cap é &3%0. Electrodo óptico OD, con 6 m de cable y sensor cap é &3%0. Electrodo óptico OD, con 15 m de cable y sensor cap é &%0$"1 Sensor cap de recambio é Oxímetro &TDBMB0% &TDBMBTBUVSBDJØO &TDBMBUFNQFSBUVSB$ DO450 OXY PORTAVO 907 yNHMQQN yNHMQQN y y y $BMJCSBDJØO $PSSFDDJØOEFUFNQFSBUVSB t $PSSFDDJØOTBMJOJEBE $PSSFDDJØOQSFTJØOBUNPTGÏSJDB 5JQPEFFMFDUSPEP t yHMBVUPNÈUJDBUSBTJOUSPEVDDJØOEFMGBDUPS .BOVBM I1B »QUJDPJHVBMEFTDSJQDJØOTJHVJFOUF »QUJDPUFDOPMPHÓBMVNJOJTDFOUF TFHÞO"45.%o )PME t (-1 t t "MBSNBDBMJCSBDJØO y QVOUPT ZQVOUPNHM %BUBMPHHFS .FNPSJBEBUPT "VUPBQBHBEP 1BOUBMMB &TUBORVFJEBE 4BMJEBT "MJNFOUBDJØO 7JEBEFMBTCBUFSÓBT %JNFOTJPOFTNN 1FTP t t .BOVBMJOUFSWBMPTPDPOUJOVP *%NVFTUSBVTVBSJP GFDIBZIPSB t t -$%SFUSPJMVNJOBEB (SÈýDB5'5SFUSPJMVNJOBEB WBSJPTJEJPNBT *1 *1 64#34 64# Y"" #BUFSÓB*PO-JUJPDBSHBCMF64# ZQJMBT"" IPSBTTJOSFUSPJMVNJOBDJØO IPSBT YY YY H H www.labprocess.es 37 Multiparamétrico de bolsillo serie 5 p)$0/%6$5*7*%"%4"-*/*%"%5%4:$&/46#0-4*--0 t1BOUBMMBSFUSPJMVNJOBEBEFDPMPSFTB[VMQBSBNFEJEBWFSEFQBSBDBMJCSBDJØOZSPKBQBSB BMBSNB t*ODMVZFNBMFUBEFUSBOTQPSUFDPOQBUSPOFTEFQ)ZDPOEVDUJWJEBEQJMBTQBQFMUJTÞZWBTPEF DBMJCSBDJØO t*OEJTQFOTBCMFFOBHSJDVMUVSBBHVBTKBSEJOFSÓBIJESPQØOJDBBDVJDVMUVSBQJTDJOBTZ41"4 UPSSFTEFSFGSJHFSBDJØOFEVDBDJØO Características técnicas Escala de Conductividad 3FTPMVDJØO SERIE 5 y 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO B 5BNQPOFTSFDPOPDJEPT 64" *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO 4J *OEJDBDJØOEFFTUBCJMJEBEEFNFEJEB 4J "MBSNBEFMFTUBEPEFMTFOTPS 4J Escala mV (redox) 3FTPMVDJØON7 yç4yç4yN4 Conductividad escala 3FTPMVDJØO &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMWBMPSMFÓEP 5BNQPOFTSFDPOPDJEPT y 1BUSPOFTSFDPOPDJEPT ç4N4 5$DPFýDJFOUFEFUFNQFSBUVSB 53UFNQFSBUVSBEFSFGFSFODJB 5%4FTDBMB y$ $ QQNQQUHM 5%4'BDUPS y 3FTPMVDJØO EFMWBMPSMFÓEP 4BMJOJEBEFTDBMB QQU 5FNQFSBUVSBFTDBMB$ y 3FTPMVDJØO1SFDJTJØO ¡$ "VUPBQBHBEP "MPTNJOUSBTQVMTBSVOBUFDMB 1BOUBMMB -$%%VBMSFUSPJMVNJOBEBBDPMPSFT 1SPUFDDJØO*1 *1 "MJNFOUBDJØO Y7"""CBUFSÓBT 7JEBEFMBTCBUFSÓBT IPSBT %JNFOTJPOFT Y 1FTP H Como pedirlo G-PCT5 PC5 Tester, completo con instrumento y electrodo de pH + Conductividad, 1 cap para calibración, disoluciones tampón pH 7.00 + pH 4.01 (botellas de 55 ml coloreadas) 1 x 10 ml de solución de mantenimiento del electrodo, disoluciones patrón 1413 μS + 12.88 mS (botellas de 55 ml) cinta de transporte, papel tisú, 4 baterías y maleta 170 € Acesorios G-RPCT5 38 Electrodo de recambio para PC5 Tester www.labprocess.es 70 € Multiparamétricos portátiles PC 7 y PC 70 "4&26*#-&4'*"#-&4:&'*$*&/5&4 tEstancos IP57SFTJTUFOUFTBMQPMWPZBMBHVBZDPOGVOEB EFHPNBTVBWFRVFTFBEBQUBDPNQMFUBNFOUFBMBGPSNB EFMFRVJQP t7JTVBMJ[BDJØOTJNVMUÈOFBFOQBOUBMMBEFMQ)DPOEVDUJWJEBE ZUFNQFSBUVSBBEFNÈTEFMJDPOPEFFTUBCJMJEBEZEFMB JOEJDBDJØOEFMPTQBUSPOFTVUJMJ[BEPTFOMBDBMJCSBDJØO tEl PC7 4BUJTGBDFMBTFYJHFODJBTEFVOFRVJQPSPCVTUPZTFODJMMP EJTF×BEPQBSBUSBCBKPEVSP tEl PC70 (-1QBOUBMMBSFUSPJMVNJOBEBDPOGFDIBZIPSB NFNPSJBT$BM5JNFS64#QBSBDPOFYJØOB1$ZDPNP GVODJØOEFBMJNFOUBDJØOFYUFSOB (1$ .VMUJQBSBNÏUSJDP1$DPONBMFUBDPNQMFUBFMFDUSPEPEFQ)ZDÏMVMBEFDPOEVDUJWJEBEDPO$"5DPODBCMFýKPNEJTPMVDJPOFT QBUSØOQ)ZDPOEVDUJWJEBEZBDDFTPSJPT é (1$ .VMUJQBSBNÏUSJDP1$DPONBMFUBDPNQMFUBDÏMVMBEFDPOEVDUJWJEBEDPO$"5DPODBCMFýKPNEJTPMVDJPOFTQBUSØOQ)ZDPO EVDUJWJEBEZBDDFTPSJPT4*/&-&$530%0Q)OJDBCMF é (1$ .VMUJQBSBNÏUSJDP1$DPONBMFUBDPNQMFUBFMFDUSPEPEFQ)ZDÏMVMBEFDPOEVDUJWJEBEDPO$"5DPODBCMFýKPNEJTPMVDJPOFT QBUSØOQ)ZDPOEVDUJWJEBEBMJNFOUBEPSBSFEDBCMF64#ZTPGUXBSF1$MJOLQBSBTBMJEBEFEBUPTB1$ é (1$ .VMUJQBSBNÏUSJDP1$DPONBMFUBDPNQMFUBDÏMVMBEFDPOEVDUJWJEBEDPO$"5DPODBCMFýKPNEJTPMVDJPOFTQBUSØOQ)Z DPOEVDUJWJEBEBMJNFOUBEPSBSFEDBCMF64#ZTPGUXBSF1$MJOLQBSBTBMJEBEFEBUPTB1$4*/&-&$530%0EFQ)OJDBCMF é Electrodos de pH H-238381 Hamilton de uso general. Polyplast, 0...14 pH, 0-60 ºC y 1m de cable conector BNC para pHmetros 7, 70, 6+ y serie 600 115 € H-242067 Hamilton de penetración en alimentos, etc. Cuerpo de plástico, 0...14 pH, 0-60 ºC y 1m de cable, conector BNC 259 € G-32200313 De penetración. Cuerpo de acero inox, 0...14 pH, 0-60 ºC, con CAT y 1m de cable, conector BNC y CINCH 195 € H-242064 Hamilton de para medios difíciles. Cuerpo de plástico, 0...14 pH, 0-60 ºC membrana plana y 1m de cable, conector BNC 235 € Células de conductividad G-2301T Célula de conductividad de 2 polos, K=1 (10μS…200 mS) 0…80ºC, CAT NTC30K, de plástico y 1 m cable. Conector CINCH 110 € SK-51/01 Célula de conductividad con sonda temperatura, K=0,1 (0,1 μS…1mS) CAT NTC30K, de plástico y acero inox, 1 m cable. Conector CINCH 185 € &TDBMBQ)N7 $BMJCSBDJØOEFQ) *OEJDBDJØOEFQPUFODJBMEF BTJNFUSÓBQFOEJFOUFZQBUSPOFTVUJMJ[BEPT PC 7 PC 70 yQ)N7 yQ)N7N7N7 BQVOUPT64"Q)/*45Q)DVTUPN Sí 4ÓDPOGFDIBZIPSB &TDBMBEFDPOEVDUJWJEBE $BMJCSBDJØOEFDPOEVDUJWJEBE yN4 BQVOUPTç4oç4oN4oN4DVTUPN &TDBMB5%4GBDUPSy yHM ooDN $POTUBOUFEFDÏMVMBTFMFDDJPOBCMF $PFýDJFOUFEFUFNQFSBUVSB 5FNQFSBUVSB $PNQFOTBDJØOEFMBUFNQFSBUVSBBVUP NBOVBM $ $ $ y¡$Q)y¡$DPOEVDUJWJEBE y¡$ Sí $SJUFSJPTFTUBCJMJEBE Sí $BMJCSBDJØOUJNFS Sí (-1 .FNPSJB .BO"VUPEBUPTDPOGFDIBZIPSB "VUPBQBHBEP 1BOUBMMB "MJNFOUBDJØO "MPTNJOVUPT -$% -$%BVUPJMVNJOBEB Y7CBUFSÓBT"""IPSBT Y7CBUFSÓBT"""BEBQUBEPS64#IPSBT 1SPUFDDJØO*1 %JNFOTJPOFTZQFTP *1 ¨¨NNH ¨¨NNH www.labprocess.es 39 Multiparamétrico de sobremesa PC 8 &"4:&4&-"%+&5*70%&-/6&704*45&." Q)$0/%6$5*7*%"%5%4Z$ tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:4VQBOUBMMBEFDPMPSFTMFNVFTUSBDPORVF QBUSPOFTIBDBMJCSBEPMBFTUBCJMJEBEEFMFDUVSBMBUFNQFSBUVSB ZFMFTUBEPEFMFMFDUSPEP tEasy to calíbrate:3FDPOPDJNJFOUPBVUPNÈUJDPEFQBUSPOFT EFQ)PEFDPOEVDUJWJEBE t"HJUBEPSNBHOÏUJDPTFQBSBCMFZNBOFKBCMFTJOFOUSBSFOFM TPGUXBSF t4PQPSUFBSUJDVMBEPQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT ESPECIFICACIONES PC 8 Escala pH y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO y64"/*4564&3 Sí *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO Sí *OEJDBDJØOEFFTUBEPEFMFMFDUSPEP $SJUFSJPEFFTUBCJMJEBEEFNFEJEB .FEJVN Escala mV (redox) Escala de Conductividad N4 3FTPMVDJØO &TDBMBBVUPNÈUJDB 1SFDJTJØO EFMBMFDUVSBMFÓEB Escala TDS NHMHSM 'BDUPS5%4 y y Temperatura escala ºC 3FTPMVDJØO1SFDJTJØO ¡$ .BOVBMPBVUPNÈUJDB/5$,û ¡$ 5FNQFSBUVSBDPNQFOTBDJØO Sí 5FNQFSBUVSBDBMJCSBDJØO 1VOUPTEFDBMJCSBDJØODPOEVDUJWJEBE 4N4 QVOUPEFýOJEPQPSFMVTVBSJP Sí *OEJDBDJØOEFDBMJCSBDJØOFTUÈOEBS 5$DPFýDJFOUFEFUFNQFSBUVSB y$ 53UFNQFSBUVSBEFSFGFSFODJB y$ Sí *OEJDBDJØOEFFTUBEPEFMBDÏMVMB 5JQPEFDÏMVMB QPMPT $POTUBOUFEFDÏMVMB 1BOUBMMB .BUSJYDPMPSFT &OUSBEBT Y#/$+BDLQIPOP"5$ "HJUBEPSNBHOÏUJDP Sí $POUSPMEFWFMPDJEBESQN 1SPUFDDJØO *1 "MJNFOUBDJØO "$%$BEBQUBEPS7 %JNFOTJPOFTZQFTP YYNNH (1$ .VMUJQBSBNÏUSJDPEFTPCSFNFTB1$94DPNQMFUPDPOFMFDUSPEPEFQ))BNJMUPO1PMJMZUF-BCDBCMFDÏMVMBEFDPOEVDUJWJEBE DPODPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFTQBUSØOQ)ZEFDPOEVDUJWJEBE4N4BHJUBEPSNBHOÏ UJDPBMJNFOUBEPSZNBOVBM é (1$ .VMUJQBSBNÏUSJDPEFTPCSFNFTB1$94DPODÏMVMBEFDPOEVDUJWJEBEDPODPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFT QBUSØOQ)ZEFDPOEVDUJWJEBE4N4BHJUBEPSNBHOÏUJDPDBCMFEFFMFDUSPEPBMJNFOUBEPSZNBOVBM 4*/&-&$530%0%&Q) é Acesorios 40 G-CATNT55 Sonda CAT, NTC 30K de inmersión, diámetro 3 mm, cuerpo inox 70 € H-355173 Cable para electrodo con conector BNC 44 € www.labprocess.es Multiparamétrico de sobremesa PC 80 &"4:&4&-"%+&5*70%&-/6&704*45&." Q)$0/%6$5*7*%"%4"-*/*%"%5%43&4*45*7*%"%Z$(-1 tEasy to use:%JTF×BEPQBSBGÈDJMVTPOPOFDFTJUBSBOJNBOVBM tEasy to read:#BTUBVOBNJSBEBZFOTVQBOUBMMBNVMUJDPMPSDPOPDFSÈFMFTUBEPEFMFMFDUSPEPDPORVF QBUSPOFTTFIBDBMJCSBEPMBFTUBCJMJEBEEFMFDUVSBMBUFNQFSBUVSBEFMBNVFTUSBGFDIBZIPSBTJFM64# FTUÈDPOFDUBEPFUD tEasy to calíbrate:$BMJCSBDJØOBVUPNÈUJDBEFQBUSPOFTEFQ)PEFDPOEVDUJWJEBE t "HJUBEPSNBHOÏUJDPTFQBSBCMFZNBOFKBCMFTJOFOUSBSFOFMTPGUXBSF t4PQPSUFBSUJDVMBEPQBSBTFOTPSFTDPOJOýOJUBTQPTJDJPOFT ESPECIFICACIONES PC 80 Escala pH y 3FTPMVDJØO 1SFDJTJØO 1VOUPTEFDBMJCSBDJØO y64"/*45%*/64&3 Sí *OEJDBDJØOEFQVOUPTEFDBMJCSBDJØO (-1DBMJCSBDJØO 4ÓDPOGFDIBZIPSB Sí *OEJDBDJØOEFFTUBEPEFMFMFDUSPEP $SJUFSJPEFFTUBCJMJEBEEFNFEJEB -PX.FEJVN)JHI "MBSNB 7BMPSFT.ÓO.ÈY Escala mV (redox) Escala de Conductividad N4BVUPNÈUJDB 1SFDJTJØO EFMBMFDUVSBMFÓEB Escala TDS NHMHSM 'BDUPS5%4 yEFMBMFDUVSBMFÓEB 4BMJOJEBE yQQUHM 3FTJTUJWJEBE y.ûEFMBMFDUVSBMFÓEB y¡$ Temperatura escala ºC 5FNQFSBUVSBDPNQFOTBDJØO .BOVBMPBVUPNÈUJDB/5$,û ¡$ Sí 5FNQFSBUVSBDBMJCSBDJØO 1VOUPTEFDBMJCSBDJØODPOEVDUJWJEBE 4N4 QVOUPEFýOJEPQPSFMVTVBSJP Sí *OEJDBDJØOEFDBMJCSBDJØOFTUÈOEBS 5$DPFýDJFOUFEFUFNQFSBUVSB y$ 53UFNQFSBUVSBEFSFGFSFODJB y$ (-1DBMJCSBDJØO 4ÓDPOGFDIBZIPSB *OEJDBDJØOEFFTUBEPEFMBDÏMVMB 4ÓDPOJDPOP 5JQPEFDÏMVMB ØQPMPT $POTUBOUFEFDÏMVMB y .FNPSJB ."/"650EBUPTDPOGFDIBZ IPSB 1BOUBMMB .BUSJYNVMUJDPMPSDPOJDPOPTZBOBMØHJDB *EJPNB &TQB×PMPUSPT Sí .BOVBMPOMJOF &OUSBEBT "HJUBEPSNBHOÏUJDP Y#/$+BDLQIPOP"5$ 64#QBSB QSJOUFSP1$64#QBSBUFDMBEPFYUFSOP 4Ó$POUSPMEFWFMPDJEBESQN 1SPUFDDJØO *1 "MJNFOUBDJØO %JNFOTJPOFTZQFTP "$%$BEBQUBEPS7 YYNNH (1$ .VMUJQBSBNÏUSJDPEFTPCSFNFTB1$94DPNQMFUPDPOFMFDUSPEPEFQ))BNJMUPO1PMJMZUF-BCDBCMFDÏMVMBEFDPOEVDUJ WJEBEEFWJESJPZ1UDPODPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFTQBUSØOQ)ZEFDPOEVDUJWJEBE4 N4BHJUBEPSNBHOÏUJDPBMJNFOUBEPSZNBOVBM (1$ .VMUJQBSBNÏUSJDPEFTPCSFNFTB1$94DPODÏMVMBEFDPOEVDUJWJEBEDPODPNQFOTBEPSEFUFNQFSBUVSBEJTPMVDJPOFT QBUSØOQ)ZEFDPOEVDUJWJEBE4N4BHJUBEPSNBHOÏUJDPDBCMFEFFMFDUSPEPBMJNFOUBEPSZ NBOVBM4*/&-&$530%0%&Q) é é Acesorios G-CATNT55 Sonda CAT, NTC 30K de inmersión, diámetro 3 mm, cuerpo inox 70 € H-355173 Cable para electrodo con conector BNC 44 € Teclado externo e impresora USB, ver página 12. www.labprocess.es 41 Temp 70 professional 5&3.».&53015%&"-5"13&$*4¶0/$0/%"5"-0(&3 t&TDBMB$$EF$ t)BTUB¡$SFTPMVDJØOTFMFDDJPOBCMFFOUSFP¡$ t.FNPSJ[BIBTUBNFEJEBTEFUFNQFSBUVSBNBOVBMPBVUPNÈUJDPBJOUFSWBMPT EFNJOVUPBIPSBT t$BMJCSBDJØOFOVOQVOUPDPONFNPSJBEFMBGFDIBZIPSB t7JTVBMJ[BMBUFNQFSBUVSBNÓOJNBZNÈYJNB t(SBOQBOUBMMBSFUSPJMVNJOBEBEFGÈDJMMFDUVSB t$SJUFSJPTEFFTUBCJMJEBEEFNFEJEBMPXNFEIJHIDPOJOEJDBDJØO t'FDIBZIPSBFOQBOUBMMB t4BMJEB64#QBSBDPOFYJØOB1$ t"MJNFOUBDJØOBUSBWÏTEF1$PBMJNFOUBEPSBSFEJODMVJEP t1SPUFDDJØO*1 t'VOEBQSPUFDUPSBEFHPNBDPOTPQPSUF t$FSUJýDBCMFQPSDVBMRVJFS$FOUSP/BDJPOBMEF$FSUJýDBDJØO&/"$QPSFKFNQMP Como pedirlo G-TEMP70-2 Temp 70 Termómetro portátil y data logger para sondas PT 100. Completo con maleta de transporte, alimentador, cable USB y software PC-link para descarga de datos. SIN SONDA 395 € Sondas Pt 100 para termómetros Temp 7 – Temp 70 Cat. nº de Escala de Punta de la Escala medida certificación sonda en °C °C Diseño Ø3 G-PT56L t90 sec. Precio -50 +400 -50 +300 30 72 € -50 +400 -50 +300 120 73 € Ø4 -50 +400 -50 +300 60 73 € Ø4 -50 +250 -50 +150 60 73 € Ø3 -50 +400 -50 +300 30 75 € -100 +300 -100 +250 30 73 € -50 +400 -50 +300 60 120 € -50 +400 -50 +300 60 130 € NN MÓRVJEPBJSF $BCMFN Ø5 G-PT56C NN $BCMFN G-PT56P DPOUBDUP NN $BCMFN G-PT56A QFOFUSBDJØO NN $BCMFN G-PT56L 1/5 DIN La más precisa BJSF NN $BCMFN Ø4 G-PT56 TFE NN $"#-& */$-6*%0 $BCMF5FþPO5FþPON *%&"-1"3"&456'"4:$0/(&-"%03&4 Ø6 G-PT56/500 NN $BCMFN Ø6 G-PT56/1000 NN $BCMFN Otros modelos de sondas PT100 disponibles bajo demanda 42 www.labprocess.es Temp 7 Basic 1"3"40/%"415%&"¡$ t$PONJDSPQSPDFTBEPS t7BMPSFT.*/Z."9 t*OEJDBEPSEFFTUBCJMJEBEEFMBNFEJEB t.FNPSJBQFSNBOFOUF t$BMJCSBCMFFYUFSOBNFOUF t"VUPBQBHBEPZSFUFODJØOEFMBMFDUVSB t*OEJDBDJØOEFMBDBSHBEFMBCBUFSÓB t.FOTBKFTEFBVUPEJBHOØTUJDP t1SPUFDDJØO*1BQSVFCBEFTBMQJDBEVSBT t'VOEBQSPUFDUPSBEFHPNBDPOTPQPSUF t$FSUJýDBCMFQPSDVBMRVJFS$FOUSP/BDJPOBMEF$FSUJýDBDJØO&/"$QPSFKFNQMP Como pedirlo G-TEMP7-2 Temp 7 Termómetro portátil para sondas PT 100. Completo con maleta de transporte. SIN SONDA 179 € Especificaciones de la precisión Sensor Escala de medida de la temperatura Clase Tolerancia máxima referida a la temperatura Pt100 ¡$ ¡$ ¡$ ¡$ DMBTF" ¡$ ¡$ ¡$ ¡$ ¡$ ¡$ ¡$ ¡$ Pt100 DMBTF ¡$ ¡$ ¡$ ¡$ T*=Temperatura medida. Se considera siempre el error mayor NTC / Pt100 Termocoppia K/T EFMWBMPSýOBM Tiempo de respuesta para la sonda inmersa en un líquido www.labprocess.es 43 Temp 7 K/T 1"3"40/%"4"5&3.01"3,05%&¡$"¡$ t3FTPMVDJØO¡$ t$PONJDSPQSPDFTBEPS t7BMPSFT.*/Z."9 t*OEJDBEPSEFFTUBCJMJEBEEFNFEJEB t.FNPSJBQFSNBOFOUF t$BMJCSBCMFFYUFSOBNFOUF t"VUPBQBHBEPZSFUFODJØOEFMBNFEJEB t*OEJDBDJØOEFMBDBSHBEFMBCBUFSÓB t.FOTBKFTEFBVUPEJBHOØTUJDP t1SPUFDDJØO*1BQSVFCBEFTBMQJDBEVSBT t'VOEBQSPUFDUPSBEFHPNBDPOTPQPSUF t$FSUJýDBCMFQPSDVBMRVJFS$FOUSP/BDJPOBMEF$FSUJýDBDJØO&/"$QPSFKFNQMP Como pedirlo G-TEMP7K-2 215 € Temp 7 K/T Termómetro portátil para sondas termopar K y T. Completo con maleta de transporte. SIN SONDA Sondas termopar K para termómetro Temp 7 K/T Cat. nº Punta de la sonda Diseño Ø2 G-3K220 NN $BCMFN Escala de medida en °C Escala de certificación °C t90 sec. Precio -60 +600 -60 +400 2 62 € -60 +800 -60 +600 3 62 € -60 +800 -60 +800 3 70 € -60 +1100 -60 +1100 6 95 € -60 +1100 -60 +1100 6 115 € -60 +1100 -60 +1000 6 85 € -50 +600 -50 +600 3 67 € -60 +600 -60 +400 15 72 € -60 +400 -60 +300 2 28 € MJRVÓEPBJSF Ø3 G-3K320 NN $BCMFN Ø3 G-3K350 NN $BCMFN Ø6 G-3K6100 NN $BCMFN ØYJEPEFNJOFSBMTPOEBþFYJCMF Ø6 G-3K6120 NN $BCMFN ØYJEPEFNJOFSBMTPOEBþFYJCMF Ø6 G-3K650 NN $BCMFN ØYJEPEFNJOFSBMTPOEBþFYJCMF Ø4 G-3K415P NN QFOFUSBDJØO $BCMFN Ø5 G-3K520C NN $BCMFN G-3K1200 DPOUBDUP Ø2 NN 4POEBEFIJMPNBOJQVMBCMF 44 www.labprocess.es Temp 7 NTC 1"3"40/%"4%&5&3.*4503/5$,%&¡$"¡$ t3FTPMVDJØO¡$ t$PONJDSPQSPDFTBEPS t7BMPSFT.*/Z."9 t*OEJDBEPSEFFTUBCJMJEBEEFNFEJEB t.FNPSJBQFSNBOFOUF t$BMJCSBCMFFYUFSOBNFOUF t"VUPBQBHBEPZSFUFODJØOEFMBNFEJEB t*OEJDBDJØOEFMBDBSHBEFMBCBUFSÓB t.FOTBKFTEFBVUPEJBHOØTUJDP t1SPUFDDJØO*1BQSVFCBEFTBMQJDBEVSBT t'VOEBQSPUFDUPSBEFHPNBDPOTPQPSUF t$FSUJýDBCMFQPSDVBMRVJFS$FOUSP/BDJPOBMEF$FSUJýDBDJØO&/"$QPSFKFNQMP &MUFSNØNFUSP5FNQ/5$FTMBPQDJØOJEFBMQBSBNFEJDJPOFTSÈQJEBTFOVOFTUSFDIPDBNQPEFUSBCBKP .VZQSÈDUJDPSFDPNFOEBEPQBSBMBJOEVTUSJBEFBMJNFOUPTQBSBFMDPOUSPMFOFMTFDUPSEFMBJSFBDPOEJDJPOBEPZQBSBUPEBTMBT NFEJEBTEFUFNQFSBUVSBFOFMRVFFTJNQPSUBOUFVOBFYDFMFOUFSFMBDJØODBMJEBEQSFDJP Como pedirlo G-TEMP7NTC-P Temp 7 NTC Termómetro portátil para sondas NTC 30K, suministrado con sonda termometrica NT7P. Completo con maleta de transporte. SIN SONDA 195 € G-TEMP7NTC-L Temp 7 NTC Kit Termómetro portátil para sondas NTC 30K, suministrado con sonda termométrica NT7L. Completo con maleta de transporte 195 € Sondas NTC 30K para termómetros Temp 7 NTC Cat. nº Punta de la sonda Diseño Ø3 G-NT7L NN Escala de certificación °C t90 sec. Precio -50 +150 -50 +150 30 70 € -50 +150 -50 +150 30 73 € MÓRVJEPBJSF $BCMFN Ø4 G-NT7P Escala de medida en °C NN $BCMFN $ CM QFOFUSBDJØO Certificados “ENAC” de temperatura y humedad 3FBMJ[BEPTQPSFM-BCPSBUPSJPEF$BMJCSBDJØOZ&OTBZPTO-$ .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wEFUFSNØNFUSPTPOEBFOQVOUPTB$ é .5 $FSUJýDBEPi&/"$wQBSBEBUBMPHHFSFOQVOUPTZ$ é .5 $FSUJýDBEPi&/"$wEFUFSNPIJHSØNFUSPTPOEBFOQVOUPT)3ZBZ$ é .5 $FSUJýDBEPi&/"$wEFUFSNPIJHSØNFUSPTPOEBFOQVOUPT)3ZBZ$ é .5 $FSUJýDBEPi&/"$wEFUFSNPIJHSØNFUSPTPOEBFOQVOUPT)3ZBZ$ é Nota: Especificar en el pedido el nombre y dirección al cual debe de figurar el certificado (la empresa que utilizará los instrumentos), así como los 5 puntos de certificación deseados. Otros valores de certificados, bajo demanda. www.labprocess.es 45 Termómetros low cost LabThermometer t&TDBMBy$SFTPMVDJØO$ t1SFDJTJØO$FOUSFy$ SFTUP$ t%JNFOTJPOFTYYNNZTPOEBYNN %4 5FSNØNFUSPEJHJUBMEFCPMTJMMP-BC5IFSNPNFUFS é ThermoJack PRO t&TDBMBEFNFEJEB5IFSNPKBDLy$ t&TDBMBEFNFEJEB5IFSNPKBDL130y$ t1SFDJTJØO$FOUSFy$ SFTUP$ t5IFSNPKBDLYYNNZTPOEBYNN t5IFSNPKBDL130YYNNZTPOEBYNN %4 5FSNØNFUSPEJHJUBMEFCPMTJMMP5IFSNP+BDL é %4 5FSNØNFUSPEJHJUBMEFCPMTJMMP5IFSNP+BDL130 é Termómetro termopar K t&TDBMBy$QSFDJTJØO$ t"MJNFOUBDJØOQJMBCPUØO$3WJEBI t%JNFOTJPOFTYYNN %4 5FSNØNFUSPEJHJUBMUFSNPQBS,4*/40/%"BENJUFMBTTPOEBTFTUÈOEBSUJQP, 6UJMJ[BMBTNJTNBTTPOEBTRVFFM UFSNØNFUSP5FSNPQBS5&.1+,5 é Termómetro LT101 t&TDBMBy$ t1SFDJTJØO$FOUSFy$ SFTUP$FOUSFy$ SFTUP$ t"MBSNBSFHVMBCMF-PX)JHI DPOBWJTPBDÞTUJDP t4PQPSUFZQMBDBNBHOÏUJDBQBSBTVQFSýDJFTNFUÈMJDBT t.FNPSJ[BDJØOEFUFNQFSBUVSBNÈYJNBNÓOJNBZ)PME t&TUBODP*1 %4-5 5FSNØNFUSPEJHJUBM-5DPOTPOEBFYUFSOBEFQFOFUSBDJØO-NNZNEFDBCMF é Termómetro LT102 t&TDBMBy$ t1SFDJTJØO$FOUSFy$ SFTUP$ t"MBSNBSFHVMBCMF-PX)JHI DPOBWJTPBDÞTUJDP t4PQPSUFZQMBDBNBHOÏUJDBQBSBTVQFSýDJFTNFUÈMJDBT t.FNPSJ[BDJØOEFUFNQFSBUVSBNÈYJNBNÓOJNBZ)PME t&TUBODP*1 %4-5 46 5FSNØNFUSPEJHJUBM-5DPOTPOEBFYUFSOBZNEFDBCMF www.labprocess.es é Termómetros portátiles infrarrojos .&%*$*»/%&5&.1&3"563"4*/$0/5"$50 &/461&3'*$*&4/03&'-&$5"/5&47*%3*0"(6" AT250 t5FSNØNFUSPJOGSBSSPKPQBSBNFEJEBTBEJTUBODJBEFCBKPDPTUF t%JTUBODJBPCKFUJWP t&TDBMBy$QSFDJTJØO$ t7FMPDJEBEEFMFDUVSBQPSTFHVOEP %4"5 5FSNØNFUSPEFMÈTFSJOGSBSSPKP54B$ é Termómetro infrarrojo AHACCP t*OEJTQFOTBCMFFOFMTFDUPSEFBMJNFOUBDJØOQSPEVDDJØODPOHFMBEPT FMBCPSBDJØOUSBOTQPSUFBMNBDFOBEPDPDJOBDBUFSJOHZSFTUBVSBOUFT t3ÈQJEPNFEJEBTFOTFHVOEPT t4JODPOUBNJOBDJØOOJOHVOBQBSUFGÓTJDBUPDBFMQSPEVDUP t-&%4EFDPMPSFOMBQBSUFJOGFSJPSEFMBQBOUBMMBQBSBJOEJDBSRVFMBTNFEJEBT FOUSBOEFOUSPEFMBFTDBMBBENJUJEB)"$$1NFEJEBTTFHVSBTPOP t$BSDBTBIJHJÏOJDBSFTJTUFOUFBMBHVBMBWBCMF t&NJTJWJEBE,BKVTUBEB QBSBBMJNFOUPT t:BEFNÈTTPOEBEFQFOFUSBDJØOUFSNPQBSQMFHBCMFQBSBQVODJØOFOBMJNFOUPT t%JTUBODJBPCKFUJWP t&TDBMBy$)BTUB$DPOMBTPOEBUFSNPQBSJOUFHSBEB t7FMPDJEBEEFMFDUVSBQPSTFHVOEP %4")"$$1 5FSNØNFUSPQPSUÈUJMJOGSBSSPKP54B$DPODFSUJýDBEPUSB[BCMF/*45FOQVOUPT é ScanTemp 385 $0/5&$/0-0(¶"*/'3"330+0#"45""13&5"3&-("5*--0:-&&3 t&TDBMB¡$¡$ t3FTPMVDJØO¡$%JHJUPT-$% t1SFDJTJØOEFMBMFDUVSBP¡$ t%JTUBODJBPCKFUJDP t5JFNQPEFSFTQVFTUBNT t3FTQVFTUBFTQFDUSBMN t1BOUBMMB3FUSPJMVNJOBEB t&NJTJWJEBEZQSPHSBNBCMF t"MJNFOUBDJØOY"""CBUFSÓBT t%JNFOTJPOFT1FTPYYNNH %4*3 5FSNPNFUSP*OGSBSSPKP4DBO5FNQDPOMBTFSØQUJDB HVAC é Las siglas HVAC corresponden al acrónimo inglés de Heating, Ventilating and Air Conditioning (calefacción, ventilación y aire acondicionado), que engloba el conjunto de métodos y técnicas que estudian y analizan el tratamiento del aire en cuanto a su enfriamiento, calentamiento , (des) humidificación, calidad, movimiento, etc. www.labprocess.es 47 Proscan 510 5&3.».&530*/'3"330+0130'&4*0/"-$0/»15*$"%&"-5"13&$*4*»/16/5&30-«4&3$0/ )";&453&$)01"3".&%*%"413&$*4"4%&0#+&5045"/1&26&º04$0.0.."$6"-26*&3 %*45"/$*"*/'&3*03".. t%JTUBODJBPCKFUJWP t&TDBMBy¡$SFTPMVDJØO$ t1SFDJTJØOP¡$y¡$ Z¡$¡$¡$y¡$ t5JFNQPEFSFTQVFTUB NT t"MBSNBBDÞTUJDBBKVTUBCMFBMUBCBKB t3FTQVFTUBFTQFDUSBMBNJDSBT t&NJTJWJEBEy t1BOUBMMBSFUSPJMVNJOBEB t-ÈTFSN8$MBTFEFMÈTFS** t%JNFOTJPOFTYYNNZQFTPH t"MJNFOUBDJØO#BUFSÓBBMDBMJOBEF7IPSBTDPOEFMÈTFSZMV[EFGPOEP IPSBTDPOMÈTFSZSFUSPJMVNJOBDJØO t"QMJDBDJPOFT)7"$MBCPSBUPSJPTFTUVGBTUFNQFSBUVSBTEFNPUPSFTZ BDDJPOBNJFOUPTDPKJOFUFTZWÈMWVMBT %4 5FSNPNFUSPJOGSBSSPKP1SP4DBODPOMBTFSZØQUJDBEFBMUBQSFDJTJØO é Proscan 520 5&3.».&530*/'3"330+0130'&4*0/"-%&"-5"13&$*4*»/*/$-640"5&.1&3"563"4 /&("5*7"4$0/3&40-6$*»/»15*$"%&"-5"13&$*4*»/:16/5&30-«4&316&35064# $"#-&:40'58"3&1"3".&%*%"40/-*/& t%JTUBODJBPCKFUJWP t&TDBMBy¡$SFTPMVDJØO$ t1SFDJTJØO$Py¡$ Z¡$y$¡$y¡$ Z ¡$y¡$ t5JFNQPEFSFTQVFTUB NT t"MBSNBBDÞTUJDBBKVTUBCMFBMUBCBKB t3FTQVFTUBFTQFDUSBMBNJDSBT t&NJTJWJEBEy t1BOUBMMBSFUSPJMVNJOBEB t'VODJPOFT.BY.ÓO4DBO)PME0GGTFU$P' t$POFDUPSQBSBFOUSBEBEFVOBTPOEBUFSNPQBSUJQP, t-ÈTFSN8$MBTFEFMÈTFS**BPGGTFUNNBODIVSB t%JNFOTJPOFTYYNNZQFTPH t"MJNFOUBDJØO#BUFSÓBBMDBMJOBEF7IPSBTDPOEFMÈTFSZ MV[EFGPOEPIPSBTDPOMÈTFSZSFUSPJMVNJOBDJØO Medida inmediata de temperatura con muy alta precisión, incluso a bajas temperaturas. Imprescindible en control de calidad en laboratorios, HVAC, mantenimiento mecánico, eléctrico… %4 5FSNPNFUSPJOGSBSSPKP1SP4DBODPOMBTFSØQUJDBEFQSFDJTJØODBCMF64#ZTPGUXBSF é ¿Qué es el ratio óptico? &TMBQSPQPSDJØOEJTUBODJBUBNB×PEFMPCKFUP1PSFKFNQMPVOSBUJPØQUJDPEFJOEJDBRVFBDNEFEJTUBODJBEFMPCKFUPPCUFOESÈ VOBTVQFSýDJFTQPUPNBODIB EFDN 48 www.labprocess.es )3 Termohigrómetros portátiles UR 100 y UR200 t-FDUVSBEFWBMPSFTNÈYJNPTZNÓOJNPT t:FMNPEFMP63DPONFEJEBEFMQVOUPEFSPDJPZFOUSBEBQBSBTPOEBEFUFSNPQBSUJQP, t&TDBMB)3)3 t1SFDJTJØO)3 t1VOUPEFSPDÓP$ t4POEBEFUFNQFSBUVSB,$PQDJPOBM 4ØMPQBSB63 (63 5FSNPIJHSØNFUSPQPSUÈUJM9463DPOQBOUBMMBEPCMF)3$ NFNPSJ[BDJØOEFWBMPSFTNÈYJNPZNÓOJNPTBMJEB34$POFTUVDIFZTPOEBEF)3$ é (63 5FSNPIJHSØNFUSPQPSUÈUJM9463DPOQBOUBMMBEPCMF)3 $NFNPSJ[BDJØOEFWBMPSFTNÈYJNPZNÓOJNPQVOUPEFSPDÓPDPOFYJØOJOEFQFO EJFOUFEFVOBTPOEBUJQP,DPOFTDBMB$ZTBMJEB34$POFTUVDIF ZTPOEBEF)3$ é Termohigrómetros de bolsillo .&%*%03%&)6.&%"%:5&.1&3"563" .¶/*.070-6.&/:.«9*.03&/%*.*&/50&/6/*/4536.&/50%&#0-4*--0.&5«-*$0.6:30#6450 t6TPFO)7"$BMJNFOUBDJØOFEJýDJPTQMBOUBTEFQSPEVDDJØOMBCPSBUPSJPT t.FEJEBTJNVMUBOFBEFUFNQFSBUVSBZIVNFEBE t'VODJØOEFWBMPSFT."9.*/ t'VODJØOQVOUPEFSPDÓPTØMPNPEFMP%4@ t'VODJØOEFTIBCJMJUBS"VUPPGGTØMPNPEFMP%4@ t'VODJØOEJGFSFODJBMFOUSFWBMPSFTNFEJPTBOUFTTØMPNPEFMP%4@ t&TDBMBEFNFEJEB$ZS)$ t1SFDJTJØO$Z SFTUP t"MJNFOUBDJØOQJMB7UJQP"""IPSBTFOVTPDPOUJOVP t%JNFOTJPOFTZQFTPYYNNHSJODMFNCBMBKF %4 5FSNPIJHSØNFUSPEJHJUBMDPOGVODJØOEJGFSFODJBMZGVODJØO."9.*/ é %4 5FSNPIJHSØNFUSPEJHJUBMDPOGVODJØO"VUP0''ZQVOUPEFSPDJP%FXQPJOU é Termohigrómetros H-560 %*4&º"%01"3")7"$ Indispensable en el estudio de calidad del aire en edificios, almacenes, lugares públicos, talleres.. t3FHJTUSPEFWBMPSFTNÈYJNPTJNÓOJNPT t4FOTPSJOUFHSBEPNBOFKBCMFDPOVOBNBOP t%PCMFQBOUBMMBEPOEFTFNVFTUSBOWBMPSFTEF$Z)3 &TDBMBEFUFNQFSBUVSB 1SFDJTJØO $$ $ &TDBMBEFIVNFEBE )3 1SFDJTJØO SFTUPFTDBMB 5FNQFSBUVSBEFUSBCBKP 'VODJPOFT $ .BY.JO)PME1VOUPEFSPDJPCVMCPIÞNFEP 1BOUBMMB -$%MJOFBT "MJNFOUBDJØO Y7PMU""" 7JEBEFMBTCBUFSÓBT IPSBTFOVTPDPOUJOVP %JNFOTJPOFTQFTP YYNNH %4) 5FSNPIJHSØNFUSPQPSUÈUJMDPOTPOEBJOUFHSBEB HVAC é Consulte para otros Termohigrómetros. www.labprocess.es 49 Microlite, Dataloggers USB -"40-6$*»/"-3&(*4530%&.&%*%"4%&5&.1&3"563")6.&%"% $033*&/5&&5$1&26&º04&/5"."º0:(3"/%&4&/13&45"$*0/&4 Modelos para registro de temperatura, humedad, corriente, voltaje… de forma sencilla y todo ello con un software de fácil uso y además gratuito! t3FHJTUSBEPSNVMUJWJBKFQBSBSFHJTUSPJOJOUFSSVNQJEPEFMBDBEFOBEFGSÓP t*OUFSGB[64#QBSBVOBSÈQJEBDPNVOJDBDJØOZQBSBMBTBDUVBMJ[BDJPOFTEFýSNXBSF t#PPNFSBOH¥GVODJØOÞOJDBRVFBVUPNÈUJDBNFOUFDSFBZFOWÓBQPSDPSSFPFMFDUSØOJDPMPTEBUPTFOEPDVNFOUP1%'BMSFNJUFOUF t3ÈQJEBEFTDBSHBEFEBUPTHSÈýDPTUBCMBTZIPKBTEFDÈMDVMP&YDFM t-$%JODPSQPSBEPQBSBMFDUVSBTDPOQVOUPEFDJNBMFJOEJDBEPS-&%EFBMBSNBZCBUFSJBCBKB t%VSBDJØOEFMBCBUFSÓBIBTUBB×PTNFEJBOUFMBUFDOPMPHÓB/BOP8BUUEFQFOEJFOEPEFMBGSFDVFODJBEFSFHJTUSP t'SFDVFODJBEFSFHJTUSPEFEBUPTEFTEFTFHVOEPBIPSBT t*OUFSSVQUPSDPOMMBWFNBHOÏUJDBQBSBNBSDBTEFUJFNQPBDUJWBSZEFUFOFSFMSFHJTUSP t3FMPKFOUJFNQPSFBMZDBMFOEBSJP t4FJODMVZFCBTFEFNPOUBKFQBSBQBSFE t1MBUBGPSNBVOJýDBEBEFTPGUXBSFEFBOÈMJTJT%BUB4VJUF Registro de temperatura '-*5&1 .JDSPMJUF1DPOFDUPS64#EBUPT4UBNQ4UPQ3VO é '-*5&1 .JDSPMJUF1DPOFDUPS64#EBUPT4UBNQ4UPQ3VO é Registro de temperatura y humedad .JDSPMJUF13)DPOFDUPS64#EBUPT5FNQFSBUVSBZIVNFEBE 4UBNQ4UPQ3VO '-*5&13) é Registro de temperatura con sonda externa .JDSPMJUF1&95DPOFDUPS64#EBUPT4UBNQ4UPQ3VO $POTPOEBFYUFSOBEFQFOFUSBDJØOYNNJODMVJEB '-*5&1&95 MICROLITE 5008P MICROLITE 5032P &TDBMB y$ 4FOTPS 1SFDJTJØO y$ y)3 y$ $ )3 $ y$ $EJTQMBZ $4PGU )3 $EJTQMBZ $4PGU 4J /" 4POEBFYUFSOB $ $EJTQMBZ $4PGUXBSF $BSHBNÈYJNB /" %FXQPJOU /" 5PNBEBUPT QPSDBOBM %FTEFTFHVOEPIBTUBIPSBT #BUFSÓB $37 7JEBCBUFSÓB B×PT 5FNQFSBUVSB EFUSBCBKP y$ "QBSUJSEF$FMSFOEJNJFOUPEFMBTQJMBTFTNVZCBKPZMBQBOUBMMB-$%QVFEFEFTWBOFDFSTFNPNFOUÈOFBNFOUF %JNFOTJPOFT YYNN 1FTP $FSUJýDBDJØO H $&&/*1 .POUBKFQBSFE Software gratis en: www.fourtec.com/downloadcenter 50 MICROLITE 5032P-EXT *OUFSOP $ 3FTPMVDJØO .FNPSJB MICROLITE 5032P-RH www.labprocess.es $&&/*1 4FJODMVZFBDDFTPSJPQBSBNPOUBKFQBSFE é Dataloggers USB %"5"-0((&34-0($0/$3&"$*»/%&1%'"650.«5*$" Los LOG32 disponen de puerto USB, que le permite conectar (sin cables) a todos los PCs con Windows. El puerto USB está protegido por una tapa de plástico transparente. t1%'TJOTPGUXBSFOPSFRVJFSFESJWFST BKVTUBEPTEFGÈCSJDBDPOJOUFSWBMPEFNJOVUPT t4PGUXBSFPQDJPOBMQBSBPUSBTGSFDVFODJBTEFNVFTUSFP t'SFDVFODJBEFNVFTUSFPBKVTUBCMFFOUSFTFHVOEPTIBTUBIPSBT t-&%EFFTUBEPZBMBSNB t"MBSNBBDÞTUJDBCFFQFS &TDBMB ¡$ 1SFDJTJØO ¡$y¡$ 3FTPMVDJØO ¡$ .FNPSJB NFEJEBT "MJNFOUBDJØO Y""TJ[FW 7JEBEFMBCBUFSÓB B×PTQBSBJOUFSWBMPEFNVFTUSFPNJOVUPT %JNFOTJPOFTQFTP YYNNH %4-0(5 %BUBMPHHFSEFUFNQFSBUVSB*ODMVZFTPQPSUFQBSFE é %4-0(53) %BUBMPHHFSEFUFNQFSBUVSBIVNFEBEZQVOUPEFSPDJP é Incluye soporte para pared. Dataloggers Log 100 LOG 100 CRYO data logger %BUBMPHHFSEJTF×BEPQBSBcriogeniaUFNQFSBUVSBIBTUB$ ÞUJMQBSBFMDPOUSPMEFMB DBEFOBEFGSJPUBOUPFOUSBOTQPSUFDPNPBMNBDFOFTDPOTPOEBJOUFSOBZTPOEBFYUFSOBPQDJPOBM UJQP1UEFBNQMJBFTDBMB LOG 100 data logger %BUBMPHHFSEJTF×BEPQBSBFMDPOUSPMEFMBDBEFOBEFGSJPUBOUPFOUSBOTQPSUFDPNP BMNBDFOFTDPOTPOEBJOUFSOBZTPOEBFYUFSOBPQDJPOBM t*OEJDBDJØOEFMFTUBEPEFMBCBUFSÓB t"MBSNBBMUBCBKBWJTVBMZBDÞTUJDB t&TDBMBEFNFEJEB$DPOTPOEBJOUFSOB$DPOTPOEBFYUFSOB15$*# t1SFDJTJØO*OUFSOB$FOUSFy$ $SFTUPFTDBMB &YUFSOB$FOUSFy$ JODFSUJEVNCSFEFMTFOTPS$SFTUPFTDBMB t1BOUBMMB-$%MJOFBT t.FNPSJBYNFEJEBT t'SFDVFODJBEFUPNBEFEBUPTTFHVOEPBIPSBT t*OUFSGBDF64# t"MJNFOUBDJØOQJMBCPUØOUJQP$3 t7JEBNFEJBEFMBQJMBB×PBJOUFSWBMPTNJOVUPT t%JNFOTJPOFTZQFTPYYNNHS 4PQPSUFEFQBSFE %4 -0($3:0EBUBMPHHFSQBSBDSJPHFOJBDPOTPOEBJOUFSOB4JOTPOEBFYUFSOBPQDJPOBM é %4 -0(EBUBMPHHFSDPOTPOEBJOUFSOB4JOTPOEBFYUFSOBPQDJPOBM é 4POEBTDPOFDUBCMFT %4 4POEB1UDPONEFDBCMF$NNZMPOHEFWBJOBNNTPMPQBSB-0($3:0 é %4 4POEB1UDPONEFDBCMF$NNZMPOHEFWBJOBNN é "DDFTPSJPTPQDJPOBMFT %4 4PGUXBSF8JOEPXT%&(SBQIQBSB-PH é %4 4PQPSUFEFQBSFEQBSBFM-PH é www.labprocess.es 51 Dataloggers para autoclave .0/*503*;"$*»/%&5&.1&3"563"4%63"/5&-"&45&3*-*;"$*»/:1"45&63*;"$*»/ 0USBTBQMJDBDJPOFTIBTUB$DPODÈMDVMPBVUPNÈUJDPEFWBMPSFT'0;Z/GVODJØOEF FYQPSUBDJØOB&YDFMZTFQVFEFOWFSWBSJBTDVSWBTTJNVMUÈOFBNFOUFFOMBTHSÈýDBT Steril Disk Micro 800 Steril Disk 30 Micro 802 Steril Disk 10 Micro 801 Steril Disk Micro 820 Steril Disk L Micro 822 Steril Disk XL Micro 824 Steril Disk flexible Micro 834 &TDBMB$ y y y y y y y 1SFDJTJØO $ $ $ $ $ $ $ &TUBORVFJEBE *1 *1 *1 *1 *1 *1 *1 1SFTJØONÈY CBS CBS CBS CBS CBS CBS CBS TFH TFH TFH TFH TFH TFH TFH Sí Sí Sí Sí Sí Sí Sí .FNPSJB *OUFSWBMPEFNFEJEB "MJNFOUBDJØOCBUFSÓBEF GÈDJMSFQPTJDJØO EÓBTB¡$ EJBTB$ EJBTB$ EJBTB$ BJOUFSWBMPT JOUFSWBMPTEFw BJOUFSWBMPTw BJOUFSWBMPTw EFw EJBTB$ JOUFSWBMPTEFw B×PT B×PT %JNFOTJPOFTNN Y Y[POB -NN Y[POB -NN Y Y Y Y TPOEBþFYJCMF- NN 4POEB &YUFSOB 7JEBNFEJBEFMBCBUFSÓB *OUFSOB &YUFSOB &YUFSOB *OUFSOB *OUFSOB *OUFSOB 1FTP H H H H H H H $BKB "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - 4PGUXBSF41%64# "QBSUF "QBSUF "QBSUF "QBSUF "QBSUF "QBSUF "QBSUF 4PGUXBSF$'3 0QDJPOBM 0QDJPOBM 0QDJPOBM 0QDJPOBM 0QDJPOBM 0QDJPOBM 0QDJPOBM $BUO %4 %4 %4 %4 %4 %4 %4 625 € 818 € 818 € 818 € 1.710 € 1.080 € 1.170 € PRECIO *Otras longitudes (10…175 mm, bajo demanda) Calculo automático de F0, Z y valor N 52 %4 4PGUXBSFEJTDPJOUFSGBDFDBCMF64#QBSBDPOFYJØOB1$ %4 #BUFSÓBEFSFDBNCJPQBSBMPTEBUBMPHHFST4UFSJM%JTL www.labprocess.es é $POTVMUBS Para conexión a latas Steril Disk Can 95 Steril Disk Can 130 5FNQFSBUVSBNÈY $ $ Steril Disk Can 148 $ 1SFDJTJØO $ $ $ &TUBORVFJEBE *1 *1 *1 1SFTJØONÈY CBS CBS CBS NJMMPOFT NJMMPOFT NJMMPOFT TFH TFH TFH Sí Sí Sí EJBTB$JOUFSWBMPTEFw EJBTB$JOUFSWBMPTEFw EJBTB$JOUFSWBMPTEFw YTFOTPSY YTFOTPSY YTFOTPSY H H H "DFSPJOPY"*4* - "DFSPJOPY"*4* - "DFSPJOPY"*4* - .FNPSJB *OUFSWBMPEFNFEJEB #BUFSÓBDBNCJBCMF 7JEBNFEJBEFMBCBUFSÓB %JNFOTJPOFTNN 1FTP .BUFSJBM 4PGUXBSF41%64# 4PGUXBSF$'3 $BUO PRECIO "QBSUF "QBSUF "QBSUF 0QDJPOBM 0QDJPOBM 0QDJPOBM %4$"/ %4$"/ %4$"/ 1.455 € 1.455 € 1.455 € Accesorios para los dataloggers para autoclaves DS-5005-0897 Roscas M5 para prensar para dataloggers serie Steril 37,50 € DS-5005-0898 Roscas M8 para engaste de sondas externas de los dataloggers Steril. Paquete de 20 piezas 37,50 € DS-5005-0899 Perno de cierre para roscas M8, para el montaje de los dataloggers Steril con sonda externa 67,50 € www.labprocess.es 53 Datanet, la solución inteligente para adquisición de datos "%26*4*$*»/%&%"5044*/$"#-&4$0/3&%4&(63".&%*"/5& &-&45«/%"3i8*3&-&44;*(#&&w4*/1²3%*%"%&%"504 3FDFQUPSZSFQFUJEPS%"5"/&5 3FDFQUPSZSFQFUJEPS%BUBOFU5SBOTNJTJØOJOBMÈNCSJDBEFEBUPTCJEJSFDDJPOBMRVFDPOPDFIBTUB%BUBOFUTZSFQFUJEPSFTDBEBSFQFUJEPS SFDPOPDFBTVWF[%BUBOFUTZPUSPTSFQFUJEPSFT *ODMVZFDBCMF.JOJ64#ZBMJNFOUBEPS é '%/-" %BUBMPHHFSXJSFMFTT%BUB/FU$DPOTFOTPSJOUFSOPEFUFNQFSBUVSBZDBOBMFTEFýOJCMFTQPSFMVTVBSJPQBSB1UUFSNPQBS,+Z5N"7 N7GSFDVFODJBZQVMTPT3FTPMVDJØO$Z$.FNPSJBQBSBEBUPT"OUFOBJOUFSOB é '%/-" %BUBMPHHFSXJSFMFTT%BUB/FU)3Z$DPOTFOTPSJOUFSOPEFIVNFEBESFMBUJWBZUFNQFSBUVSBZDBOBMFTQBSB1UUFSNPQBS,+Z5N"7 N7GSFDVFODJBZQVMTPT3FTPMVDJØO$Z$.FNPSJBQBSBEBUPT"OUFOBJOUFSOB é '%"5"46*5&%/ 4PGUXBSF%BUB4VJUFDPODBCMF64#ZNBOVBM#BTF8JOEPXTEBUPTFOQBOUBMMBEFUBCMBTZHSBýDBTDPOWFSTJØOB&YDFMEBUPTFOUJFNQPSFBM EFýOJDJØOEFTFOTPSFTQ)$0FUDy JODMVZFTPGUXBSFEFDBMJCSBDJØOOJWFMFTEFBMBSNBQSPHSBNBTTFQBSBEPTDPOSFUBSEPEFBMBSNBZ EVSBDJØO ZVTVBSJPT"OÈMJTJTEFQVOUPEFSPDÓP'0QBTUFVSJ[BDJØOFUD0QDJØOEFVQEBUFýSNXBSFWÓBXFC&OFTQB×PM é '%4$'3%/ 4PGUXBSF%BUBQBTT$'3QBSUDPODBCMF64#ZNBOVBM#BTF8JOEPXTEBUPTFOQBOUBMMBEFUBCMBTZHSBýDBTDPOWFSTJØOB&YDFMEBUPT FOUJFNQPSFBMEFýOJDJØOEFTFOTPSFTQ)$0FUDy JODMVZFTPGUXBSFEFDBMJCSBDJØOOJWFMFTEFBMBSNBQSPHSBNBTTFQBSBEPTDPOSFUBSEP EFBMBSNBZEVSBDJØO ZVTVBSJPT"OÈMJTJTEFQVOUPEFSPDJØ'0QBTUFVSJ[BDJØOFUD0QDJØOEFVQEBUFýSNXBSFWÓBXFC'VODJØOFTQFDÓýDB EFMB$'3$POMMBWF64#EFTFHVSJEBE é '%/3" .ØEVMPT%BUBMPHHFS 4POEBTEFUFNQFSBUVSB "15$ 4POEBEFUFNQFSBUVSB1UUJQP"QBSBDSJPHFOJBFTDBMBB$DBCMF1'"EJÈNN7BJOBBDFSPJOPYEJÈYNNNDBCMF é "15$ 4POEBEFUFNQFSBUVSB1UUJQP"QBSBDSJPHFOJBFTDBMBB$DBCMF1'"EJÈNN7BJOBBDFSPJOPYEJÈYNNNDBCMF é "154 4POEBEFUFNQFSBUVSB1UUJQP"FTUÈOEBSFTDBMBB$DBCMF1'"EJÈNN7BJOBBDFSPJOPYEJÈYNNNDBCMF é "154 4POEBEFUFNQFSBUVSB1UUJQP"FTUÈOEBSFTDBMBB$DBCMF1'"EJÈNN7BJOBBDFSPJOPYEJÈYNNNDBCMF é "154 4POEBEFUFNQFSBUVSB1UUJQP"FTUÈOEBSFTDBMBB$DBCMF1'"EJÈNN7BJOBBDFSPJOPYEJÈYNNNDBCMF é "15".# 4POEBEFUFNQFSBUVSB1UUJQP"VUJMJ[BDJØOTPMPQBSB".#*&/5&FTDBMBB$TFOTPSBMBJSFDPODNDBCMF é '%5 4POEBEFIVNFEBEZUFNQFSBUVSB7 )3Z$$BCMFN é "DDFTPSJPT 54 ' $BCMFNJOJ64#QBSB3FDFQUPS ' #BUFSÓBSFDBSHBCMFJOUFSOBQBSBFM%"5"/&5VOJEBE ' .ØEFN(4.34&;QBSB%BUBMPHHFS%"5"/&5TJOUBSKFUB4*.$POTPGUXBSFEFEJDBEPB%"5"/&5 é ' 64#PWFS*1TIBSFTFSWFSDPOFYJØOB-"/ é ' .ØEVMPEFBMBSNBWJTVBMZBDÞTUJDB é -1 %FUFDUPSEFGBMMPEFDPSSJFOUFQBSBTJTUFNB%BUBMPHHFS é ' 4FOTPSNBHOÏUJDPEFQVFSUBBCJFSUB www.labprocess.es é é é Dataloggers Datanet Daqlink 710 y 720 t4PGUXBSFTJNQMFZEFGÈDJMOBWFHBDJØOQPSMPTNFOÞT t.FEJEBTFOUJFNQPSFBMEBUPTUBCMBTHSÈýDPTZFTUBEÓTUJDBT t'VODJPOBNJFOUPJOEFQFOEJFOUFCBUFSÓBSFDBSHBCMFTJOUFSOBT PDPOFDUBEPBM1$ tOJWFMFTEFBMBSNB t$POUJOVPBMNBDFOBNJFOUPEFEBUPTBMBNFNPSJB t'ÈDJMEFOPNJOBDJØOEFTPOEBTZEBUBMPHHFSTJODMVTPFOGVODJPOBNJFOUP t&OWÓPTEFBMBSNBWÓB4.4PFNBJMNFEJBOUFNPEFNFYUFSOP t1PTJCJMJEBEEFB×BEJSPRVJUBSDPOUBDUPTZHSVQPTEFEJTUSJCVDJØOEFBMBSNBTQPS4.4PFNBJM t3FHJTUSPEFBDUVBMJ[BDJPOFTWÓBýSNXBSFHSBUVJUP t%FýOJDJØOEFOVFWPTTFOTPSFTNFEJBOUFMBFOUSBEBN"QPEFNPTDPOFDUBSDVBMRVJFSWBSJBCMF t1PTJCJMJEBEEFDBMJCSBDJPOFTBUSBWÏTEFMNJTNPTPGUXBSF t&YQPSUBSBIPKBEFDÈMDVMP&YDFMTPMPQVMTBOEPVOCPUØO t1SPEVDDJØOEFJOGPSNFT Dataloggers Daqlink 710 y 720 %0#-&6401035«5*-0'*+0$0/&/53"%")"45"40/%"4&95&3/"4 Y les permite medir: 4POEBTEFUFNQFSBUVSB1UZUFSNPQBSIVNFEBEDPSSJFOUFN" BN7B7DPOUBEPSEFQVMTPTPGSFDVFODJBZQPSFKFNQMPQPESÈDPOFDUBSVO Q)NFUSPVODPOEVDUÓNFUSPVONFEJEPSEFDBVEBMTJEJTQPOFOEFTBMJEBN" FUD '%#4"" %BR-JOL$%BUBMPHHFSDPOTFOTPSEFUFNQFSBUVSBJOUFSOPZFOUSBEBQBSBTPOEBTFYUFSOBT/PJODMVZFTPOEBT "MJNFOUBDJØODPOCBUFSÓBSFDBSHBCMFJODMVJEB PBMJNFOUBEPSEFDPSSJFOUFZDFSUJýDBEPEFDBMJCSBDJØO é '%#4"" %BR-JOL$Z)3%BUBMPHHFSDPOTFOTPSEFUFNQFSBUVSBZIVNFEBEJOUFSOPZFOUSBEBQBSBTPOEBTFYUFSOBT/PJODMVZF TPOEBT"MJNFOUBDJØODPOCBUFSÓBSFDBSHBCMFJODMVJEB PBMJNFOUBEPSEFDPSSJFOUFZDFSUJýDBEPEFDBMJCSBDJØOEFGÈCSJDB é 4PGUXBSF '%"5"46*5&%2- 4PGUXBSF1$4VJUFDPODBCMF64#ZNBOVBM '%4$'3%2- 4PGUXBSF%BUB1BTT$'3QBSUDPODBCMF64#ZNBOVBM'VODJØOFTQFDÓýDBEFMB$'3$POMMBWF64#EFTFHVSJEBE é é * A diferencia del Datanet, estos dataloggers toman datos directamente de las sondas y no transmiten inalámbricamente. Pueden coger datos de forma autónoma y volcarlos a voluntad un tiempo despúes o permiten estar conectados siempre a un PC, mediante conexión USB. En este caso dispone de posibilidad de transmitir alarmas a distancia via mensaje de correo electrónico (por ejemplo a un Smartphone) o conectar un modem para envio de SMS. DAQPRO -"40-6$*»/50%0&/6/01"3"%"5"-0((*/("/«-*4*4 t4JTUFNBEFBERVJTJDJØOEFEBUPTQPSUÈUJMEFCJUTEFBMUBSFTPMVDJØO tDBOBMFTCBKPDPTUFQPSDBOBM t1BOUBMMBHSÈýDBWBMPSFTNFEJEPTUBCMBTHSÈýDPTZGVODJPOFTEFBOÈMJTJT t%JTF×BEPQBSBQSPQPSDJPOBSVOTJTUFNBQSPGFTJPOBMEFBMUBDBQBDJEBEDPOBNQMJB WBSJFEBEEFBQMJDBDJPOFTZCBKPDPTUP '%# %BUBMPHHFSDPOFOUSBEBTTFMFDDJØOEFN"N77/5$ 1UUFSNPQBSQVMTPTZGSFDVFODJBB$WFMPDJEBEEFNVFT USFPWBSJBCMFEFTEFNVFTUSBIPSBBTFHVOEP"MJNFOUBDJØOBCBUFSÓB PFYUFSOBJODMVZFTPGUXBSFQBSBBOÈMJTJT%BR-BC8JOEPXTDPODBCMFEF DPNVOJDBDJØOBMJNFOUBEPS"$%$ZNBMFUBEFUSBOTQPSUF4JO4POEBT é *Sondas de temperatura y accesorios: los mismos del Datanet www.labprocess.es 55 Colorimetros &26*1041"3".&%*%"%&$-030%63&;"0;0/0 Pooltester 3 .&%*%"%&$-030-*#3&:505"-«$*%0$*"/Á3*$0:1) NPEFMPTNHMZNHM 141)% 1PPMUFTU1BMJOUFTUNHMQQN DPNQMFUPDPOJOTUSVDDJPOFTDVCFUBTWBSJMMBTQBSBUSJUVSBSQBTUJMMBTDFQJMMPZDBSUØO DPOUBCMFUBTQBSBNFEJEBEFDMPSPMJCSFZUPUBMÈDJEPDJBOÞSJDPZQ) é Pooltester 6 .&%*%"%&$-030%63&;"%&$"-$*0"-$"-*/*%"%#30.0«$*%0$*"/Á3*$0:1) -FDUVSBEJSFDUBDPOEPCMFMPOHJUVEEFPOEBDPOýMUSPTEFCBOEBFTUSFDIBZGPUPEFUFDUPSFT 141)% 1PPMUFTU1BMJOUFTUNHMQQN DPNQMFUPDPONBMFUBJOTUSVDDJPOFTDVCFUBTWBSJMMBTQBSBUSJUVSBSQBTUJMMBTDFQJMMPZ DBSUPOFTEFUBCMFUBTQBSBNFEJEBEFDMPSPEVSF[BBMDBMJOJEBECSPNPÈDJEPDJBOÞSJDPZQ) -1 $BMJCSBDJØO'PUØNFUSPT$PNQBDU1BMJOUFTU1PPMUFTUFSZ é 141$ 1BUSPOFTQBSB1PPMUFTUFSZDPNQVFTUPQPSýMUSPTEFEFOTJEBEOFVUSBDPODFSUJýDBEP é é Clorómetro duo &4$"-"4$-030)"45".(-:$-030)"45".(1154 $MPSPNFUSP%601BMJOUFTUEPTFTDBMBTNHMZIBTUBNHMQQN DPNQMFUPDPOJOTUSVDDJPOFTDVCFUBTWBSJMMBTQBSB USJUVSBSQBTUJMMBTDFQJMMPZUFTUQBSBNFEJEBEFDMPSP%1%ZDMPSP)3ZBDJEJýDBOUF(1 é 115$ $IFDL4UBOEBSETEFMNFEJEPS$MPSPNFUSP%VPMÓRVJEP DPODFSUJýDBEP é Ozono t.FEJEBEF0[POPSFTJEVBMEFTEFBQQN t&TUBODP*1ZDPOØQUJDB-&% 1154 .FEJEPSEF0[POPQPSUÈUJMFTDBMByNHMJODMVZFDBKBEFSFBDUJWPTUVCPTQSFOTBQBTUJMMBTDFQJMMPQBSBMJNQJF[B EFUVCPTZNBOVBM é 115$ $IFDL4UBOEBSETQBSBP[POP/%' DPNQVFTUPQPSýMUSPTEFEFOTJEBEOFVUSB$PODFSUJýDBEP é 115 5VCPTQBSBDMPSØNFUSPEVP1PPMUFTUSFSZ0[POP é Amoniaco t5SFTFTDBMBTEFTEFIBTUBNHMQQN t-POHJUVEEFPOEBONON t1BSBUVCPTEFNNJODMVJEPBEBQUBEPS 56 1154 .FEJEPSEFBNPOJBDP1BMJOUFTUFTDBMBTNHM/NHM /ZNHM/DPNQMFUPDPOJOTUSVDDJPOFTZBEBQUBEPSEFUVCPT é 115$ $IFDL4UBOEBSETEFMNFEJEPSEFBNPOJBDP/%'/FVUSBM%FOTJUZ'JMUFS é www.labprocess.es Reactivos para los colorímetros 11. 1BRVFUFEFUBCMFUBTQBSB$MPSPP#SPNP-JCSF%1% EFNHM é 1"1 1BRVFUFEFUBCMFUBTQBSB$MPSPP#SPNP-JCSF%1% EFNHM é 11. 1BRVFUFEFUBCMFUBTQBSB$MPSP5PUBM%1% EFNHM é 1"1 1BRVFUFEFUBCMFUBTQBSB$MPSP5PUBM%1% EFNHM é 11. 1BRVFUFEFUBCMFUBTQBSB$MPSP-JCSF%1% EFNHM é 1"1 1BRVFUFEFUBCMFUBTQBSB$MPSP-JCSF%1% EFNHM é 11. 1BRVFUFQBSBUFTUQBSBEFUFSNJOBDJØOEFDMPSPMJCSF é 1"1 1BRVFUFEFUBCMFUBTQBSB$MPSPMJCSF é 11. 1BRVFUFEFUBCMFUBTQBSB"MDBMJOJEBE"MLBQIPU NHM é 1"1 1BRVFUFEFUBCMFUBTQBSB"MDBMJOJEBE"MLBQIPU NHM é 11. 1BRVFUFEFUBCMFUBTQBSB%VSF[BEFDBMDJP$BMDJDPM NHM é 1"1 1BRVFUFEFUBCMFUBTQBSB%VSF[BEFDBMDJP$BMDJDPM NHM é 11. 1BRVFUFEFUBCMFUBTQBSB«DJEP$JBOÞSJDPNHM é 1"1 1BRVFUFEFUBCMFUBTQBSB«DJEP$JBOÞSJDPNHM é 11. 1BRVFUFEFUBCMFUBTQBSBQ) é 1"1 1BRVFUFEFUBCMFUBTQBSBQ) é 1"5 1BRVFUFEFUBCMFUBTEF(MJDJOB%1% é 1"5 1BRVFUFEFUBCMFUBTEFBDJEJýDBDJØO%1%QBSB$-0TJFTQSFDJTP é 1"5 1BRVFUFEFUBCMFUBTEFOFVUSBMJ[BDJØO%1%QBSB$-0TJFTQSFDJTP é 11. 1BRVFUFEFUBCMFUBTQBSB$MPSPMJCSFBMUBDPODFOUSBDJØOEFoNHM é 1"1 1BRVFUFEFUBCMFUBTQBSB$MPSPMJCSFBMUBDPODFOUSBDJØOEFoNHM é 1"5 1BRVFUFEFUBCMFUBTQBSBBDJEJýDBDJØO(1VTPDPO1."1 11- 1BRVFUFEFUFTU/FTTMFS QBSBBNPOJBDPNHM/ 1BDL/ é 11- 1BRVFUFEFUFTU/FTTMFS QBSBBNPOJBDPNHM/ 1BDL/ é 11- 1BRVFUFEFUFTU/FTTMFS QBSBBNPOJBDPNHM/ 1BDL/ é 11. 1BRVFUFEFUBCMFUBT%1%QBSB0[POPJODMVZFHMJDJOBOFDFTBSJBQBSBFMUFTU é 1"1 1BRVFUFEFUBCMFUBT%1%QBSB0[POPNHM TJOHMJDJOB é 1"5 #PUFMMBTSFBDUJWPMÓRVJEPQBSBDMPSPMJCSFCPUFMMBT"#EFUFSNJOBDJPOFTBQSPY DPOTVMUBS é Pooltester Cloro y pH, visual 141 ,JUQBSBQBSBDPOUSPMWJTVBMEFDMPSPZQ)DPNQVFTUPEFDPOUFOFEPSUBCMFUBT%1%ZUBCMFUBTSPKPGFOPM é Chlordiox Plus 1"3"%&5&3.*/"$*»/%&%*»9*%0%&$-030$-030:$-03*504*/3&"$5*704 t-BNÈTBMUBQSFDJTJØO t&TDBMByNHM$M0ZNFEJEBTIBTUB$ t4JOJOUFSGFSFODJBEFTØMJEPTPEJTPMVDJPOFTDPMPSFBEBT t.ÏUPEPDSPOPBNQFSPNÏUSJDPSFTVMUBEPTNJOVUP t%JTF×BEPTQPS1BMJOUFTURVFFMJNJOBMBTVCKFUJWJEBEEFMPQFSBEPS t$POEBUBMPHHFSZDPOFYJØOB1$NFEJBOUFQVFSUP64# t"MJNFOUBDJØOQJMBT""PBUSBWÏTEF64# t.FEJEBTYYNNQFTPH 1$4 1BRVFUFEFTFOTPSFTEFSFDBNCJPQBSBNFEJSDMPSPMJCSFZ UPUBM é 1$4 1BRVFUFEFTFOTPSFTEFSFDBNCJPQBSBNFEJSDMPSPMJCSFZ UPUBM é 1$%9 $)-03%*091-64,JUQBSBEFUFS NJOBDJØOEFEJPYJEPEFDMPSPDMPSJUP ZDMPSPMJCSFDPOTFOTPSFTQBSB DBEBEFUFSNJOBDJØOZBDDFTPSJPT é 1$4 $)-03%*09&/4&,JUQBSBEFUFS NJOBDJØOEFEJPYJEPEFDMPSPFTDBMB yNHM$M0DPOTFOTP SFTEFSFDBNCJPZBDDFTPSJPT é 0USPTBDDFTPSJPT 3FDBNCJPTEFTFOTPSFT 1$%9 1$4 1BRVFUFEFTFOTPSFTEFSFDBNCJPQBSBNFEJSEJØYJEPEF DMPSPZPDMPSJUP é 1BRVFUFEFTFOTPSFTEFSFDBNCJPQBSBNFEJSEJØYJEPEF DMPSPZPDMPSJUP é 1$4 $IMPSEJP9$IFDL4UBOEBSET 115 $SVTIJOH4UJSSJOH3PETQBRVFUFEFV é 115 3FDBNCJPEFMSFDJQJFOUFEFNVFTUSBT é 115 (MJDJOBSFBDUJWP é 115 &RVJQPEFEFTHBTBNJFOUP é 115 #PNCBEFEFTHBTF é 115 'JMUSPEFSFDBNCJPEFEFTHBTF é 115 $33FBDUJWPQBSBEFUFSNJOBDJØOEFDMPSJUP é 115 $33FBDUJWPQBSBEFUFSNJOBDJØOEFDMPSJUP é 115 64#$BCMF é é www.labprocess.es 57 Fotómetro 7100 Palintest 4*&.13&"16/50:$0/-04.&+03&43&46-5"%04 *OTUSVNFOUPTQPSUÈUJMFTQBSBEFUFSNJOBDJØOEFMPTQSJODJQBMFTQBSÈNFUSPTFOBHVBT 7BMPSBODPOFYUSFNBQSFDJTJØOFMDPMPSGPSNBEPFOMBNVFTUSBZMFFOFOQBOUBMMBFMWBMPSEFMBDPODFOUSBDJØO /VODBNÈTSFTVMUBEPTFSSØOFPTEFCJEPBMBTDPOEJDJPOFTEFMV[PMBTWBSJBDJPOFTFOMBQFSDFQDJØOEFMPQFSBEPS 5PEPTMPTNÏUPEPTFOFTQB×PM t1BOUBMMBFOFTQB×PMBEFNÈTEFPUSPTJEJPNBT SFUSPJMVNJOBEB t4FMFDDJØOEFMBMPOHJUVEEFPOEBBVUPNÈUJDB t&MFDDJØOEFMNÏUPEPDPOTØMPQVMTBSVOBUFDMB t'ÈDJMTFMFDDJØOEFMNÏUPEPFTDPHJEPEFVOBMJTUB t&MTPGUXBSFMFSFDVFSEBMPTQBSÈNFUSPTEFMUFTUNÈTSFDJFOUF t6OTPMPCMBODPQBSBUPEBTMBTMPOHJUVEFTEFPOEB t"VUPDPOUSPMEFMBØQUJDBQBSBBTFHVSBSNFEJEBTFTUBCMFT t/POFDFTJUBDBMFOUBNJFOUPQBSBFNQF[BSBNFEJS ESPECIFICACIONES -0/(*56%&4%&0/%" 13&$*4*»/ 3&40-6$*»/ .&.03*"*/5&3/" 4"-*%"%&%"504 "-*.&/5"$*»/ $6#&5"4 &45"/26&*%"% %*.&/4*0/&4:1&40 :ON "53"/4.*5"/$*"""6 "6 3&46-5"%04 64#8"5&31300' 1*-"4""01$*0/"-.&%*"/5&64#%&4%&&-1$ PNN$0/"+645&"650.«5*$0"-%*«.&5304*/"%"15"%03 *1 YYNNZH Fotómetro 7500 &41&$*'*$"$*0/&4*(6"-"-:"%&.«4 t6QEBUFSFNPUPWÓB*OUFSOFUPFNBJM t*OUFSGBTF64#EFGÈDJMVTPQBSBUSBOTGFSJSEBUPTBM1$ t.FNPSJBQBSBSFTVMUBEPTDPOGFDIBZIPSB t)BTUBNÏUPEPTEFýOJCMFTQPSFMVTVBSJPFONFNPSJB t7BMPSFTEFMEBUBMPHHFSFOQBOUBMMB t"VEJU5SBJMDPNQMFUPQBSBSFTVMUBEPT 58 115 'PUØNFUSP1BMJOUFTULJUDPONBMFUBUVCPTNNDBCMFDPOFYJØO64#QBSBBMJNFOUBDJØOPWPMDBEPEFEBUPT KFSJOHBNMFTDPCJMMBWBSJMMBTQBSBUSJUVSBSQBTUJMMBTZUVCPEFEJTPMVDJØO.BOVBMFOFTQB×PM é 115 'PUØNFUSP1BMJOUFTULJUDPONBMFUBUVCPTNNDBCMFDPOFYJØO64#QBSBBMJNFOUBDJØOPWPMDBEPEFEBUPT KFSJOHBNMFTDPCJMMBWBSJMMBTQBSBSJUVSBSQBTUJMMBTZUVCPEFEJTPMVDJØO.BOVBMFOFTQB×PM é 115&6 "MJNFOUBEPSEFDPSSJFOUFDPOFOUSBEBBMGPUPNFUSP64# é 115 "MJNFOUBEPSEFDPSSJFOUFEFTEFFM1$NFEJBOUFDBCMF64# é 115 5VCPTQBSBGPUØNFUSPTZUVCPT 115 #MPRVFDBMFOUBEPSQBSBUVCPTEFSÈQJEPDBMFOUBNJFOUP 115 $IFDL4UBOEBSETQBSBGPUPNFUSPTZQBUSPOFTEFWBMJEBDJØO DPODFSUJýDBEP www.labprocess.es é é é Reactivos Palintest para los fotómetros 5&45 &4$"-"NHM UFTU "MDBMJOJEBE5PUBM"MLBQIPU $B$0 1BRVFUFQBSBUFTU 11. é 1BRVFUFQBSBUFTU 1"1 é "MDBMJOJEBE."MLBQIPU. $B$0 11. é 1"1 é "MDBMJOJEBE1"MLBQIPU1 $B$0 11. é 1"1 é "MVNJOJP 11. é 1"1 é "NPOJBDP / 11.DPO"5 é 1"1TJO"5 é #SPNP 11. é 1"1 é %VSF[BDÈMDJDB$BMDJDPM $B$0 11. é 1"1 é $MPSVSP$IMPSJEPM /B$M 11. é 1"1 é é $MPSPMJCSFNPOPDMPSBNJOHZEJDMPSBNJOB%1% 11. é 1"1 $MPSPMJCSF%1% 11. é 1"1 é $MPSP%1% NHM 11. é 1"1 é $MPSP%1%SBOHPBMUP NHM 11. é 1"1 é $MPSPMJCSFZUPUBM%1% 11. é 1"1 é $MPSPUPUBMSFTJEVBM%1% 11. é 1"1 é $MPSP)3SBOHPBMUP 11. é 1"1 é %JØYJEPEF$MPSP%1% 11. é 1"1 é $MPSP-3SBOHPCBKP 11. é 1"1 é $MPSP)3SBOHPBMUP 11. é 1"1 é $SPNP7*$ISPNJDPM 11. é 1"1 é $PCSF$PQQFSDPM MJCSF o o 1"1 é $PCSF$PQQFSDPM 11. é 1"1 é $PMPS5VSCJEF[ VOJEBEFT)B[FO 11. é o o «DJEPDJBOÞSJDP 11. é 1"1 é 0YÓHFOPEJTVFMUPWJBMFT 11- é 11-3 o 0YÓHFOPEJTVFMUPWJBMFT 11- é 11-3 o 0YÓHFOPEJTVFMUPWJBMFT 11- é 11-3 o 'MVPSVSPT 11. é 1"1 é %VSF[BUPUBM)BSEJDPM $B$0 11. é 1"1 é )JESBDJOB 11. é 1"1 é 1FSØYJEPEFIJESØHFOP-3 11. é 1"1 é 1FSØYJEPEFIJESØHFOP)3 11. é 1"1 é )JFSSP-3 o 1"1 é )JFSSP)3 11. é 1"1 é )JFSSP.3 11. é 1"1 é .BOHBOFTP 11. é 1"1 é .PMJCEBUP-3 11. é 1"1 é .PMJCEBUP)3 11. é 1"1 é /JUSBUP/JUSBUFTU 11. é 1"1 é /ÓRVFM/JDLFMUFTU / 11. é 1"1 é /JUSJUP/JUSJDPM / 11. é 1"1 é /JUSJUP/JUSJQIPU /B/0 11. é 1"1 é 0SHBOPGPTGPOBUP01 10 11. é 1"1 é 0[POP 11. é 1"1 é Q)SPKPGFOPM oQ) 11. é 1"1 é 'FOPM1IFOPMUFTU 11. é 1"1 é 1).##JPDJEBBCBTFEFQPMJCJHVBOJEP 11. é 1"1 é 'PTGBUP-3 11. é 1"1 é 'PTGBUP)3 11. é 1"1 é 1PUBTJP 11. é 1"1 é 4JMJDF 11. é 1"1 é 4JMJDF)3 11. é 1"1 é 4VMGBUP 11. é 1"1 é 4VMGVSP 11. é 1"1 é 4VMýUP4VMQIJUFTU /BSO 11. é 1"1 é ;JOD 11. é 1"1 é .BOHBOFTP)3 11. é 1"1 é UFTUUFTUUFTU 053043&"$5*704$0/46-5"3 www.labprocess.es 59 Reactivos para aguas residuales Tubetest $"%"56#056#&5&45*/$03103"-043&"$5*704/&$&4"3*041"3"&-5&45"&'&$56"3 Tubetest COD (DQO) 5&457*5"-1"3"$0/0$&3-"$"-*%"%%&-04&'-6&/5&4:"(6"43&4*%6"-&4"/5&4%&46%&4$"3(" "×BEJSFMBHVBTFUBQBZTFDPMPDBFOFMEJHFTUPSEVSBOUFIPSBTB$VOBWF[FOGSJBEPTTFNJEFFMDPMPSDPOFMGPUØNFUSP $BU/ %FTDSJQDJØOUFTUQPSDBKB DVCFUBT0NN 3BOHPNHM 11- $0%5VCFUFTUTTJONFSDVSJP é 11- $0%5VCFUFTUTTJONFSDVSJP é 11- $0%5VCFUFTUTTJONFSDVSJP é 11- $0%5VCFUFTUTTJONFSDVSJP é 11- $0%.5VCFUFTUTDPONFSDVSJP é 11- $0%.5VCFUFTUTDPONFSDVSJP é 11- $0%.5VCFUFTUTDPONFSDVSJP é 11- $0%.5VCFUFTUTDPONFSDVSJP é 11- $0%.5VCFUFTUTQBMUPDPOUFOJEPEFDMPSVSPT é 11- $0%.5VCFUFTUTQBMUPDPOUFOJEPEFDMPSVSPT é 11- $0%5VCFUFTUTQBMUPDPOUFOJEPEFDMPSVSPT é 11- $0%.$5VCFUFTUTDPONFSDVSJP é 11- $0%.$5VCFUFTUTDPONFSDVSJP é 11- $0%.$5VCFUFTUTDPONFSDVSJP é $0%$)&$,45"/%"3%4 11- $IFDL4UBOEBSETNHMDBEVDJEBENFTFT é 11- $IFDL4UBOEBSETNHMDBEVDJEBENFTFT é 11- $IFDL4UBOEBSETNHMDBEVDJEBENFTFT é 11- $IFDL4UBOEBSETNHMDBEVDJEBENFTFT é Tubetest para amoniaco y nitratos -PT5VCFUFTUEFBNPOJBDPNJEFOFYBDUBNFOUFFMBNPOJBDPFOMBTBHVBTSFTJEVBMFTFOUPEPFMFTQFDUSPEFOJWFMFTOPSNBMFTEF MBSFHMBNFOUBDJØO&MQSJNFSUFTUSFBDUJWPTFTVNJOJTUSBFOVO5VCFUFTUTFMMBEPFMTFHVOEPFOVOOVFWPEJTQFOTBEPS6OBWF[ TFIBB×BEJEPMBNVFTUSBBM5VCFUFTUTFB×BEFFMTFHVOEPSFBDUJWPEFTEFFMEJTQFOTBEPS5SBTVONJOVUPFMUVCPZBTFQVFEF MFFSFOFMGPUØNFUSP Fosfatos 56#&5&451"3"'04'"50'»4'030:'»4'030505"- 60 $BU/ %FTDSJQDJØOUVCPTQPSDBKB 11- "NPOJBDP//.ÏUPEP*OEPGFOPM oZoNHM/ é 11- "NPOJBDP/.ÏUPEP/FTTMFS oNHM/ é 11- "NPOJBDP/.ÏUPEP/FTTMFSJODMVZFCPUFMMBDPOSFBDUJWP/FTTMFSZQJQFUB oNHM/ é 11- /JUSBUP/ oNHM/ PNHM/0 é 11- /JUSØHFOPUPUBM oNHM/ é 11- 'PTGBUP1 oNHM1 PNHM10 é 11- 'ØTGPSPUPUBM oNHM1 é 11- $PCSF oNHM$V é 11- /JRVFM oNHM/J é 11- )JFSSP oNHM'F 11- ;JOD oNHM;O 11- $SPNPUPUBM oNHM$S é 11- $SPNPIFYBWBMFOUF7* oNHM$S é www.labprocess.es 3BOHPNHM é é Turbidímetros Portátiles Turbidímetro LW-TN3024 %&'«$*-."/&+04»-0#050/&4:16/504%&$"-*#3"$*»/"%&.«4%&6/"(3"/ 1"/5"--"26&'"$*-*5"-"4-&$563"4 t$POMÈNQBSBJOGSBSSPKBDPOGPSNFBMB&/*40*&$ t3FHJTUSPEFNFEJEBTNÈYJNBTZNÓOJNBTDPOGVODJØOEFNFNPSJB t 4VTJTUFNBØQUJDPQFSNJUFBMJOTUSVNFOUPMFFSEFTEFWBMPSFT/56IBTUB/56 DPOSFTPMVDJØOEF/56Ø/56TFHÞOFTDBMB ESPECIFICACIONES &TDBMB 3FTPMVDJØO 1SFDJTJØO 5JFNQPEFSFTQVFTUB 7PMVNFOEFNVFTUSBSFRVFSJEP )PME 1VOUPTEFDBMJCSBDJØO "MJNFOUBDJØO %JNFOTJPOFTZQFTP ""/56 /56/56 '4P/56FMRVFTFBNBZPS .FOPSBTFHVOEPT NM 3FUFODJØOEFEBUPT /56Z/56 #BUFSÓBEF7Y""" YYNNH -85/ 5VSCÓEJNFUSPQPSUÈUJM5/DPNQMFUPDPONBMFUBCBUFSÓBTQBUSPOFTZ/56DVCFUBTZNBMFUB -8/56 %JTPMVDJØOQBUSØO/56WJBMEFNM é é -8/56 %JTPMVDJØOQBUSØO/56WJBMEFNM é -87*"- 7JBMEFSFDBNCJPQBSBUVSCJEJNFUSP-85/ é Turbidímetro TN100 Eutech $0/-«.1"3"*/'3"330+"$0/'03.&"-"&/*40 t$VNQMFOMBOPSNB"'/03/'&/*40RVF FGFDUÞBMBNFEJEBEFMBMV[EJGVTBBRVF QFSNJUFNFEJSFOMÓRVJEPTDPMPSFBEPT tFTDBMBTBVUPNÈUJDBTEFTEFB/56 t4FTVNJOJTUSBDPONBMFUBQBUSPOFTZDVCFUBT t$BMJCSBDJØOFOQVOUPT t'VFOUFEFMV[FNJTPS*3ONMPOHJUVEEFPOEB &5/ 5VSCÓEJNFUSPQPSUÈUJM5/EFMV[*3JOGSBSSPKBFTDBMBBVUPNÈUJDB/56$PONBMFUBEFUSBOTQPSUF DVCFUBTZQBUSPOFTBQSPCBEPT&1"EFZ/56 é 3FDBNCJPT5VSCJEÓNFUSP5/ &5/$"- +VFHPEFCPUFMMBTEFNMBQSPCBEPT&1"EFZ/56QBSBUVSCJEÓNFUSP4JOWJBMFT &5/$675 +VFHPEFDVCFUBTQBSBUVSCJEÓNFUSPTZDPMPSÓNFUSPTQPSUÈUJMFT&VUFDI é é Compact Palintest &-$0.1"$5563#*.&5&365*-*;"-"&9$-64*7"5&$/0-0(¶"26"%015*9 t7BSJPTNPEPTGVODJPOBMFTEFMFDUVSBJODMVZFOEPFMUPUBMEFTØMJEPTFOTVTQFOTJØONHM/56'56Z'/6 t6ODPNQMFUPSFHJTUSPEFEBUPTRVFJODMVZFIPSBGFDIB*%EFPQFSBSJP *%EFNVFTUSBZSFHJTUSPEFDBMJCSBDJØOFODVNQMJNJFOUPEFMBT(-1IBTUBNVFTUSBT t$FSUJýDBEPTFHÞOMBOPSNB*40 "MUBSFTPMVDJØOEF/56FOVOSBOHPEFo/56DPOVOSBOHPEJOÈNJDPEF /56QSPQPSDJPOBNFEJDJPOFTýBCMFTEFMBUVSCJEF[ZEFMPTTØMJEPTFOTVTQFOTJØO t1BOUBMMBSFUSPJMVNJOBEBFOFTQB×PM t$VCFUBTEFEJÈNFUSPNNZDBQBDJEBENM 115) $PNQBDU5VSCJNFUFSNPEFMP$5 EFUFDOPMPHÓB2VBEPQUJ9DPODVCFUBTFTUÈOEBSFTEFDBMJCSBDJØO4%7# QBRVFUFTEFCBZFUBTMJNQJBEPSBTUVCPEFEJMVDJØOBDFJUFEFTJMJDPOBZDFQJMMPEFMJNQJF[BFOVOSPCVTUPFTUVDIFSÓHJEP 115$ +VFHPEFFTUÈOEBSFT4%7#EFSFQVFTUPQBSB$PNQBDU5VSCJNFUFSDPODFSUJýDBEPEFWBMJEBDJØO é é www.labprocess.es 61 Turbidímetros de sobremesa .0%&-045#%*3.&%*$*»/103-6;*326&1&3.*5&.&%*3&/ -¶26*%04$0-03&"%04:5#%8%&-6;#-"/$"1"3""(6"4 105"#-&4:3&4*%6"-&4 t &M5#%*3DVNQMFMBOPSNB"'/03/'&/*40 t 1SJODJQJPEFNFEJEBOFGFMPNÏUSJDPAOPOSBUJP SJDBT t&M5#%8DPOMÈNQBSBEFUVOHTUFOPDVNQMFMBOPSNB64"&1"NÏUPEPQBSBNFEJEBT/56/FGFMPNÏUSJDBT t(-1GFDIBZIPSB &5#%*3 5VSCÓEJNFUSP5#%*3EFMV[*3JOGSBSSPKBFTDBMBBVUPNÈUJDB/56ZTBMJEB34$DPNQMFUPDPO QBUSPOFTZ/56 ZDVCFUBTEFSFDBNCJP"MJNFOUBDJØODPOQJMBTCPUØO é &5#%8 5VSCÓEJNFUSP5#%8EFMV[CMBODBEFUVOHTUFOPFTDBMBBVUPNÈUJDB/56TBMJEB34$DPNQMFUPDPO QBUSPOFTZ/56 ZDVCFUBTEFSFDBNCJP"MJNFOUBDJØODPOQJMBTCPUØO é 3FDBNCJPTUVSCJEÓNFUSPTEFTPCSFNFTB &5#%8$"- +VFHPEFQBUSPOFTEFZ/56QBSBUVSCJEÓNFUSP5#%8 &5#%*3$"- +VFHPEFQBUSPOFTEFZ/56QBSBUVSCJEÓNFUSP5#%*3 é &5#%$675 +VFHPEFDVCFUBTQBSBUVSCJEÓNFUSPTEFTPCSFNFTB5#%8Z5#%*3 é é Disoluciones patrón de turbidez Reagecon 62 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 178 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 178 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 178 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 83 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 231 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 231 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 231 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 231 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 116 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 231 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 189 € 3$34 1BUSØOEFUVSCJEF[/P3BUJP/56YNM 392 € www.labprocess.es Espectrofotómetro Onda V-10 &41&$530'05».&5307*4*#-&#«4*$01"3"640(&/&3"-:"/«-*4*4%&365*/" t6TPFOMBCPSBUPSJPTGBSNBDÏVUJDPTDMÓOJDPTZWFUFSJOBSJPTFEVDBDJØOy t$POTFMFDDJØONBOVBMEFMPOHJUVEEFPOEB t$PNQPOFOUFTEFBMUBDBMJEBERVFHBSBOUJ[BOVOSFOEJNJFOUPFYDFMFOUF t "VUPDFSPZCMBODP t -FDUVSBEFMBMPOHJUVEEFPOEBEJSFDUBNFOUFFOQBOUBMMB t .FEJEBEFBCTPSCBODJBUSBOTNJUBODJBZDPODFOUSBDJØO t $VBOUJUBUJWPDVSWBFTUÈOEBSZNÏUPEPTEFDPFýDJFOUFT t 4PGUXBSFCÈTJDPQBSBBNQMJBSMBTBQMJDBDJPOFTBMBDVSWBZMBDJOÏUJDBFTUÈOEBS t %JPEPEFUFDUPSGPUPNÏUSJDPEFTJMJDJPEFBMUBDBMJEBEZSFKJMMBEFMÓOFBTNN BTFHVSBOVOBBMUBQSFDJTJØOZFYBDUJUVE t $PNQBSUJNJFOUPQBSBDPMPDBDJØOEFDFMEBTEFNN t (SBOQBOUBMMB-$%YQVOUPT t 1VFSUP64#QBSBDPOUSPMSFNPUPEF1$ZQVFSUPQBSBMFMPQBSBJNQSFTJØOEJSFDUB t %JTF×PEFQSFBMJOFBEPEFMÈNQBSBRVFBTFHVSBFMGÈDJMDBNCJPQPSFMQSPQJPVTVBSJP ( &TQFDUSPGPUØNFUSP0/%"7SBOHPEFBONBODIPEFCBOEBONVOTPMPIB[JODMVZFOEPDFMEBTØQUJDBT EFWJESJPTPQPSUFEFMBDFMEBEFQPTJDJPOFTDBCMFEFBMJNFOUBDJØOTPGUXBSFCÈTJDPQBSB1$DBCMF64#ZGVOEB $PNQMFUPDPO$FSUJýDBEPUSB[BCMFB4UBOEBSE%,% é Espectrofotómetro ONDA UV-20 &41&$530'05».&530677*4 %JTF×BEPQBSBVTPJOUFOTJWPFOFMDPOUSPMEFDBMJEBEFOJOEVTUSJBBMJNFOUBSJBBOÈMJTJTEFBHVBTJOEVTUSJBWJOÓDPMBFEVDBDJØOy $FSUJýDBEP%,%JODMVJEP t -POHJUVEEFPOEBBVUPNÈUJDB t .FEJEBEFBCTPSCBODJBUSBOTNJUBODJBZDPODFOUSBDJØO t $VBOUJUBUJWPDVSWBFTUÈOEBSZNÏUPEPTEFDPFýDJFOUFT t $PNQBSUJNJFOUPQBSBDPMPDBDJØOEFDFMEBTEFNN t (SBOQBOUBMMB-$%YQVOUPT RVFNVFTUSBMBDVSWBQBUSØOZDPFýDJFOUFT t HSVQPTEFEBUPTFOQBOUBMMBFOHSVQPTEF t &MTJTUFNBHVBSEBMPTSFTVMUBEPTEFHSVQPTEFEBUPTZDVSWBTQBUSØOZTJTF EFTFBWFSJýDBSMPTZDBSHBSMPTOVFWBNFOUF t 3FTUBVSBDJØOEFEBUPTFODBTPEFDPSUFEFBMJNFOUBDJØO t 1VFSUP64#ZQVFSUPQBSBMFMPQBSBJNQSFTPSB t %JTF×PEFQSFBMJOFBEPEFMÈNQBSBRVFBTFHVSBFMGÈDJMDBNCJPQPSFMQSPQJPVTVBSJP t -ÈNQBSBEF5VOHTUFOPZ%FVUFSJPDPOQVFTUBFONBSDIBJOEFQFOEJFOUFQBSBBMBSHBSTV WJEBÞUJM ( &TQFDUSPGPUØNFUSP0/%"67SBOHPEFBONBODIPEFCBOEBONIB[TJNQMFKVFHPEFMPOHJUVEEFPOEB EJHJUBMJODMVZFOEPDFMEBTØQUJDBTEFWJESJPDÏMVMBTØQUJDBTEFDVBS[PTPQPSUFEFMBDFMEBEFQPTJDJPOFTDBCMFEF BMJNFOUBDJØOTPGUXBSFCÈTJDPQBSB1$DBCMF64#GVOEBZDFSUJýDBEPEFUFTUEFDBMJEBE%,% é www.labprocess.es 63 Espectrofotómetro Onda UV-30 SCAN &41&$530'05».&530%&#"33*%0677*4%&"-503&/%*.*&/50 t*OTUSVNFOUPEFFMFDDJØOQBSBMBJOEVTUSJBBMJNFOUBSJBGBSNBDÏVUJDBBHVBTWJOÓDPMBF*% t4FJODMVZFVOTPGUXBSFBQMJDBUJWPQSPGFTJPOBMRVFQFSNJUFVUJMJ[BSMPTNÏUPEPTNÈTJNQPSUBOUFTQBSBFMBOÈMJTJTDVBOUJUBUJWP ZDVBMJUBUJWP t'VODJPOFT$VBOUJUBUJWBTDJOÏUJDBTUFTU%/"QSPUFÓOBTDBOOFSEFMPOHJUVEEFPOEBy $POGVODJØOEFTVTUSBDDJØOEFCMBODPBVUPNÈUJDPRVFQFSNJUFSFBMJ[BSFMBOÈMJTJTFOUPEPFMSBOHPEFMPOHJUVEEFPOEB t#BSSJEPBVUPNÈUJDPNFEJBOUF1$TPGUXBSFJODMVÓEP t4JTUFNBØQUJDPEFIB[ÞOJDPDPOCMBODPBVUPNÈUJDP t -POHJUVEEFPOEBBVUPNÈUJDB t -ÈNQBSBEF5VOHTUFOPZ%FVUFSJPDPOQVFTUBFONBSDIBJOEFQFOEJFOUFQBSB BMBSHBSTVWJEBÞUJM t 'VODJPOFT$VBOUJUBUJWBFTDBOFBEPEFMPOHJUVEEFPOEBDJOÏUJDBNVMUJMPOHJUVE EFPOEBZUFTU%/"1SPUFÓOB t &TUBCMFDJNJFOUPEFJOUFSWBMPTEFEBUPTFOFMFTDBOFBEPEFMPOHJUVEEFPOEB t $VBOUJUBUJWPDVSWBFTUÈOEBSZNÏUPEPTEFDPFýDJFOUFT t (SBODPNQBSUJNJFOUPQBSBDPMPDBDJØOEFDFMEBTDPOTPQPSUFTPQDJPOBMFT t (SBOQBOUBMMBHSÈýDB-$%YQVOUPT t &MTJTUFNBHVBSEBMPTSFTVMUBEPTEFHSVQPTEFEBUPTZIBTUBDVSWBTQBUSØO $POSFDVQFSBDJØOEFEBUPTFODBTPEFGBMMPEFBMJNFOUBDJØO t 3FTUBVSBDJØOEFEBUPTFODBTPEFDPSUFEFBMJNFOUBDJØO t 4PGUXBSFQSPGFTJPOBMRVFQFSNJUFFMDPOUSPMUPUBMEFMFTQFDUSPGPUØNFUSPEFTEF FM1$BNQMJBOEPTVGVODJPOBMJEBEQBSBBOÈMJTJTFTQFDUSBMFTBVUPEFUFDDJØOEF QJDPWBMMFDÈMDVMPEFMFTQFDUSPZFYQPSUBSEBUPTBIPKBEFDBMDVMP'VODJØO.VMUJXM QBSBBOÈMJTJTEFWJOPT t %JTF×PEFQSFBMJOFBEPEFMÈNQBSBRVFBTFHVSBFMGÈDJMDBNCJPQPSFMQSPQJPVTVBSJP ( &TQFDUSPGPUØNFUSP0/%"674$"/SBOHPEFONBODIPEFCBOEBEFONIB[TJNQMFDPODFMEBTØQUJDBTEFWJESJPZEF DVBS[PTPQPSUFQBSBDFMEBTDBCMFEFBMJNFOUBDJØOZDBCMF64#TPGUXBSFQSPGFTJPOBMQBSB1$GVOEBCompleto con Certificado trazable a Standard DKD ESPECTROFOTÓMETRO "VUPDFSPZCMBODP "KVTUFEFMPOHJUVEEFPOEBBVUPNÈUJDB "ODIPEFCBOEBFTQFDUSBM 4JTUFNBØQUJDP ONDA UV-20 ONDA UV-30 SCAN "VUPBKVTUFEFMPOHJUVEEFPOEB "VUPBKVTUFEFMPOHJUVEEFPOEB yON yON yON ON ON ON )B[TJNQMFSFKJMMBMÓOFBTNN )B[TJNQMFSFKJMMBMÓOFBTNN )B[TJNQMFSFKJMMBMÓOFBTNN ON ON ON 3FQFUJUJWJEBEMPOHJUVEEFPOEB ON ON ON 1SFDJTJØOGPUPNÏUSJDB 3FQFUJUJWJEBEGPUPNÏUSJDB &TDBMBGPUPNÏUSJDB %FTWJBDJØOIB[EFMV[ &TUBCJMJEBE 1BOUBMMB .PEPGPUPNÏUSJDP %FUFDUPS 1PSUBDFMEBTFTUÈOEBS ON ON ON 5P"CT!"CT 5P"CT!"CT 5 5 5 5 y5y"y $POD y5y"y$POD y5y"y $POD 5 õ5 õ5!ON "I!ON "I!ON "I!ON -$%HSBýDBYQJYFMT -$%HSBýDBYQJYFMT -$%HSBýDBYQJYFMT 5"CT$POD'BDUPS 5"CT&OFSHZ 5"CT&OFSHZ 'PUPEJPEPEFTJMJDJP 'PUPEJPEPEFTJMJDJP 'PUPEJPEPEFTJMJDJP $BNCJBEPSDFMEBEFNNEF QPTJDJPOFT $BNCJBEPSDFMEBEFNNEF QPTJDJPOFT $BNCJBEPSDFMEBEFNNEF QPTJDJPOFT $PNQBSUJNFOUPEFNVFTUSBT $FMEBFTUÈOEBSNN $FMEBFTUÈOEBSNN $FMEBFTUÈOEBSNN 'VFOUFEFMV[ -ÈNQBSBEF5VOHTUFOP -ÈNQBSBTEF5VOHTUFOPZ%FVUFSJP -ÈNQBSBTEF5VOHTUFOPZ%FVUFSJP 64#QBSBDPOUSPMFYUFSOPEF1$ 64#QBSBDPOUSPMFYUFSOPEF1$ 64#QBSBDPOUSPMFYUFSOPEF1$Z TFSJFQBSBMFMBQBSBJNQSFTPSB "MJNFOUBDJØO _7"$)[ _7"$)[ _7"$)[ %JNFOTJPOFT YYON YYON YYON LH LH LH 4BMJEB 1FTP 64 ONDA V-10 "VUPDFSPZCMBODP 1SFDJTJØOMPOHJUVEEFPOEB 3FTPMVDJØOMPOHJUVEEFPOEB é www.labprocess.es Accesorios para Espectrofotómetros 4PQPSUFTQBSBDVCFUBTQBSB77Z7 ( 4PQPSUFQBSBDVCFUBTDBNJOPØQUJDPNN é ( 4PQPSUFQBSBDVCFUBTDBNJOPØQUJDPNN é $VCFUBTDVBESBEBTQBSB7*4*#-&EFWJESJPØQUJDPFTQFDJBMQBSB77Z7 ( $VCFUBDVBESBEBNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBNN+VFHPEFDVCFUBT é "DDFTPSJPTQBSBFTQFDUSPGPUØNFUSPT7Z74PQPSUFTQBSBDVCFUBT ( 4PQPSUFQBSBDVCFUBDJMÓOESJDBEJÈNFUSPNNUJQP$0% é $VCFUBTDVBESBEBTEFDVBS[PQBSB67 ( $VCFUBDVBESBEBQBSBDBNJOPØQUJDPEFNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBQBSBDBNJOPØQUJDPEFNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBQBSBDBNJOPØQUJDPEFNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBQBSBDBNJOPØQUJDPEFNN+VFHPEFDVCFUBT é ( $VCFUBDVBESBEBQBSBDBNJOPØQUJDPEFNN+VFHPEFDVCFUBT é "DDFTPSJPTQBSBFTQFDUSPGPUØNFUSP74PQPSUFTQBSBDVCFUBT ( 4PQPSUFQBSBNJDSPDÏMVMBBMUVSBEFMIB[NN é ( 4PQPSUFBVUPNÈUJDPQBSBDVCFUBDVBESBEBEFQPTJDJPOFT é ( 4PQPSUFQBSBDVCFUBDJMÓOESJDBEJÈNFUSPNN é $VCFUBTDVBESBEBTEFDVBS[P.*$30QBSB67 ( $VCFUBDVBESBEBEFçMQBSBDBNJOPØQUJDPEFNN é ( $VCFUBDVBESBEBEFçMQBSBDBNJOPØQUJDPEFNN é ( $VCFUBDVBESBEBEFçMQBSBDBNJOPØQUJDPEFNN é $VCFUBTEFþVKPBMUVSBEFIB[NN ( DVCFUBEFþVKPQBSBDBNJOPØQUJDPEFNNEFWJESJPØQUJDP é ( DVCFUBEFþVKPQBSBDBNJOPØQUJDPEFNNEFDVBS[P é 4JTUFNB4JQQFSZ1FMUJFSBMUVSBEFIB[NN ( 4JQQFS"QBSBDÏMVMBEFþVKP é ( 1FMUJFS"QBSBUFNQFSBUVSBDPOTUBOUF é ( 4JQQFS1FMUJFS"QBSBDÏMVMBEFþVKPZUFNQFSBUVSBDPOTUBOUF é 'JMUSPDFSUJýDBEP ( ,JUEFDBMJCSBDJØOýMUSPTØMJEP)FMMNBQBSBMPOHJUVEFTEFPOEB677JTEFQSFDJTJØO DPOUJFOF''''$POGPSNFBMB'BSNBDPQFBFVSPQFB é ( ,JUEFDBMJCSBDJØOýMUSPTØMJEP)FMMNB67QSFDJTJØOGPUPNÏUSJDBDPOUJFOF676767 é ( 4PQPSUFQBSBQSPCFUBTUVCPT iUFTUUVCFIPMEFSwDPOEJÈNFUSPFOUSFZNNBMUVSBEFMIB[ BDNEFTEFFMGPOEPEFMBQSPCFUBZVOBBMUVSBIBTUBNNUJQP%20 é www.labprocess.es 65 5 Estufas e incubadores Argolab ")03"$0//6&704130(3"."%03&4 t 1SPHSBNBEPSDPOQBOUBMMB-$%SFUSPJMVNJOBEBRVFNVFTUSBDMBSBNFOUFFO DBEBNPNFOUPMBUFNQFSBUVSBQSPHSBNBEBMBJOUFSOBZPUSPTQBSÈNFUSPT t -BJOUSPEVDDJØOEFJDPOPTiVTFSGSJFOEMZwGBDJMJUBMBJOUFSQSFUBDJØOEFMBT GVODJPOFTZDPNBOEPTEFGPSNBFYUSBPSEJOBSJBNFOUFJOUVJUJWB t *ODMVZFODFSUJýDBEP"DDSFEJBEFDBMJCSBDJØOB$ PROGRAMADOR BÁSICO PROGRAMADOR PROFESIONAL "EFNÈTEFMBTFTQFDJGJDBDJPOFT EFM#"4*$ t1BOUBMMBSFUSPJMVNJOBEB t*DPOPTEFGÈDJMMFDUVSB t5JNFSZGVODJØODPOUJOVB t"MBSNBWJTVBMZTPOPSB t$POUSPMWFMPDJEBEEFMWFOUJMBEPS t-JNJUBEPSEFUFNQFSBUVSBEFTFHVSJEBE t%FNPSBEFBSSBORVFEFMQSPHSBNB t7 programas x 10 pasos tRepetición de ciclos de trabajo *Sólo en estufas con ventilación forzada (high, medium, Low) ESTUFAS DE CONVECCIÓN NATURAL TCN 30 7PMVNFO TCN 115 TCN 200 MJUSPT MJUSPT MJUSPT MJUSPT $ $ $ $ )PNPHFOFJEBEEFMB UFNQFSBUVSBB$ $ $ $ $ 7BSJBDJØOB$ $ $ $ $ 5JFNQPEFDBMFOUBNJFOUPB $ NJO NJO NJO NJO IINJOZDPOUJOVP IINJOZDPOUJOVP IINJOZDPOUJOVP IINJOZDPOUJOVP 78 78 78 78 YYNN YYNN YYNN YYNN NN NN NN NN LH LH LH LH YYNN YYNN YYNN YYNN LH LH LH LH (5$/ (5$/ (5$/ (5$/ 755 € 995 € 1.380 € 1.990 € /0 (5$/130 (5$/130 (5$/130 1.200 € 1.550 € 2.100 € ( ( ( ( 40 € 55 € 80 € 100 € ( ( ( ( 35 € 45 € 75 € 90 € 5FNQ.ÈY3FTPMVDJØO 5FNQPSJ[BEPS 4FHVSJEBEDMBTF "MJNFOUBDJØOQPUFODJB %JNFOTJPOFTJOUFSOBT 8Y)Y% &TUBOUFTTVNJOJTUSBEPT NÈYJNP %JTUBODJBÞUJMFOUSFFTUBOUFT $BSHBNÈYJNBLH %JNFOTJPOFTFYUFSOBT 8Y)Y% 1FTP Cat .nº Programador BASIC Precio Cat .nº Programador PROFESIONAL Precio Estantes de rejilla Precio Plataforma de acero agujereada aplicable al estante de rejilla Precio 66 TCN 50 www.labprocess.es 5 Estufas de aire forzado: 2 versiones: Básica y Profesional $0/530-&'*$*&/5&%&-"5&.1&3"563"%&4%&$)"45"$ t 4VDPOUSPMBEPS1*%DPOBNQMJBQBOUBMMBSFUSPJMVNJOBEBEFDPMPSNVFTUSBTJFNQSFMBUFNQFSBUVSBQSPHSBNBEBMBJOUFSOBZUPEPTMPT QBSÈNFUSPT t 1FSNJUFBKVTUBSUSFTOJWFMFTEFWFMPDJEBEEFDJSDVMBDJØOGPS[BEBEFMBUFNQFSBUVSBBMUBNFEJBZCBKBHBSBOUJ[BOEPEFFTUBNBOFSBVOB QFSGFDUBIPNPHFOFJEBEFOUPEBTMBTQBSUFTEFMBFTUVGB t 4FTVNJOJTUSBDPOVOPSJýDJPFOTVQBSUFTVQFSJPSBýOEFQPEFSDPOFDUBSVOBTPOEBEFUFNQFSBUVSBQBSBTVWFSJýDBDJØOPDFSUJýDBDJØO t *ODMVZFODFSUJýDBEP"DDSFEJBEFDBMJCSBDJØOB$ ESTUFAS DE CONVECCIÓN FORZADA TCF 50 TCF 120 TCF 200 TCF 400 MJUSPT MJUSPT MJUSPT MJUSPT $ $ $ $ 7BSJBDJØOB$ $ $ $ $ 5JFNQPEFDBMFOUBNJFOUPB $ NJO NJO NJO NJO IINJOZDPOUJOVP IINJOZDPOUJOVP IINJOZDPOUJOVP IINJOZDPOUJOVP 78 78 78 78 YYNN YYNN YYNN YYNN NN NN NN NN LH LH LH LH YYNN YYNN YYNN YYNN LH LH LH LH (5$' (5$' (5$' (5$' 1.150 € 1.600 € 2.140 € 3.460 € (5$'130 (5$'130 (5$'130 (5$'130 1.350 € 1.800 € 2.340 € 3.660 € ( ( ( ( 55 € 80 € 90 € 150 € ( ( ( ( 45 € 75 € 100 € 130 € 7PMVNFO 5FNQ.ÈY3FTPMVDJØO )PNPHFOFJEBEEFMB UFNQFSBUVSBB$ 5FNQPSJ[BEPS 4FHVSJEBEDMBTF "MJNFOUBDJØOQPUFODJB %JNFOTJPOFTJOUFSOBT 8Y)Y% &TUBOUFTTVNJOJTUSBEPT NÈYJNP %JTUBODJBÞUJMFOUSFFTUBOUFT $BSHBNÈYJNBLH %JNFOTJPOFTFYUFSOBT 8Y)Y% 1FTP Cat .nº Programador BASIC Precio Cat .nº Programador PROFESIONAL Precio Estantes de rejilla Precio Plataforma de acero agujereada aplicable al estante de rejilla Precio www.labprocess.es 67 5 Incubadores de convección natural t -PTNBUFSJBMFTPSHÈOJDPTVUJMJ[BEPTFOMBTBQMJDBDJPOFTUÓQJDBTEFMBCPSBUPSJPSFRVJFSFOVODBMFOUBNJFOUPTVBWFDPOTUBOUF t -BEJTUSJCVDJØOEFMBUFNQFSBUVSBFOMPTJODVCBEPSBT"SHPMBCTFPCUJFOFTJOBJSFGPS[BEPVUJMJ[BOEPTØMPMBDPOWFDDJØOOBUVSBMMPDVBMOP FTUSFTBMBNVFTUSBZQFSNJUFTVDSFDJNJFOUPVOJGPSNF t 4VBODIBQVFSUBEFWJESJPQFSNJUFWJHJMBSDPOTUBOUFNFOUFMBTNVFTUSBTFOTVJOUFSJPSTJOOFDFTJEBEEFBCSJSMBQVFSUBZFWJUBOEPDBNCJPT CSVTDPTEFUFNQFSBUVSB t *ODMVZFODFSUJýDBEP"DDSFEJBEFDBMJCSBDJØOB$ INCUBADORES DE CONVECCIÓN NATURAL 7PMVNFO 5FNQ.ÈY3FTPMVDJØO ICN 16 ICN 35 ICN 55 ICN 120 ICN 200 MJUSPT MJUSPT MJUSPT MJUSPT MJUSPT $ $ $ $ $ )PNPHFOFJEBEEFMB UFNQFSBUVSBB$ $ $ $ $ $ 7BSJBDJØOB$ $ $ $ $ $ 5JFNQPEFDBMFOUBNJFOUPB $ NJO NJO NJO NJO NJO IINJO ZDPOUJOVP IINJO ZDPOUJOVP IINJO ZDPOUJOVP IINJO ZDPOUJOVP IINJO ZDPOUJOVP 5FNQPSJ[BEPS 4FHVSJEBEDMBTF 78 78 78 78 78 YYNN YYNN YYNN YYNN YYNN "MJNFOUBDJØOQPUFODJB %JNFOTJPOFTJOUFSOBT 8Y)Y% &TUBOUFTTVNJOJTUSBEPTNÈYJNP NN NN NN NN NN LH LH LH LH LH YYNN YYNN YYNN YYNN YYNN LH LH LH LH LH (*$/ (*$/ (*$/ (*$/ (*$/ 650 € 775 € 1.100 € 1.320 € 2.050 € (*$/130 (*$/130 (*$/130 (*$/130 (*$/130 850 € 975 € 1.300 € 1.520 € 2.250 € %JTUBODJBÞUJMFOUSFFTUBOUFT $BSHBNÈYJNBLH %JNFOTJPOFTFYUFSOBT 8Y)Y% 1FTP Cat .nº Programador BASIC Precio Cat .nº Programador PROFESIONAL Precio Para una perfecta homogeneidad, el sistema de calentamiento está ubicado en el interior de las paredes internas de la cámara del incubador Estantes de rejilla Precio 68 www.labprocess.es ( ( ( ( ( 35 € 45 € 55 € 80 € 105 € ~ Baños de agua %&4%&$5&.1&3"563"".#*&/5&)"45"$ .BOUFOHBMBUFNQFSBUVSBEFTVTNVFTUSBTDPOTUBOUFT t -BCB×PTEFBHVBTFSJF"SHPMBC8#HSBDJBTBMBUFNQFSBUVSBNÈYJNBEFUSBCBKPEF¡$MFTQFSNJUFOTFSVUJMJ[BEPTFOOVNFSPTBT BQMJDBDJPOFT t &MNPEFMPEF8#DPOCPNCBEFSFDJSDVMBDJØOBTFHVSBVOBEJTUSJCVDJØONÈTSÈQJEBZNÈTVOJGPSNFEFMBUFNQFSBUVSB ESPECIFICACIONES WB 12 WB 22 MJUSPT MJUSPT MJUSPT ¡$ ¡$ ¡$ )PNPHFOJEBEEFMBUFNQFSBUVSBB ¡$ ¡$ ¡$ ¡$ &TUBCJMJEBEEFMBUFNQFSBUVSBB¡$ ¡$ ¡$ ¡$ /0 /0 4* IINJOZ DPOUJOVP IINJOZ DPOUJOVP IINJOZ DPOUJOVP 1SPUFDDJØOEFTPCSFDBMFOUBNJFOUP 4* 4* 4* 4FHVSJEBEDMBTF YNN YNN YNN 7PMVNFOÞUJM 5FNQFSBUVSBNÈY3FTPMVDJØO #PNCBEFSFDJSDVMBDJØO 5JNFS %JNFOTJPOFTEFMBQMBDBEFGPOEP "MUVSBÞUJMNÓOJNBDPOUBQBDFSSBEB WB 22PUMP NN NN NN 78 78 78 YY YY YY LH LH LH $BUO ( ( ( Precio 400 € 680 € 740 € "MJNFOUBDJØO %JNFOTJPOFTFYUFSOBT8Y)Y% NN 1FTP ( 3BDLQBSBUVCPTNNQPTJDJPOFT é ( 3BDLQBSBUVCPTNNQPTJDJPOFT é ( 3BDLQBSBUVCPTNNQPTJDJPOFT ( 3BDLQBSBUVCPTNNQPTJDJPOFTCJCFSPO é ( 3BDLQBSBCPMTBTEFTBOHSFQPTJDJPOFT é 5VCPTNN NØEVMP 5VCPTNN NØEVMP é 5VCPTNN NØEVMP 5VCPTNN NØEVMP #PMTBTQBSBTBOHSF NØEVMP www.labprocess.es 69 LabProcess, expertos en aplicaciones 1)3&%09$0/%6$5*7*%"%09¶(&/0%*46&-50$-030563#*%&;"/"-*;"%03&4$"6%"-y Soluciones fiables y seguras para el control de procesos /VFTUSPLOPXIPXZFYQFSJFODJBOPTQFSNJUFOEBSSFTQVFTUBBDVBMRVJFSBQMJDBDJØOQPSDSÓUJDBRVFFTUBTFB %FTEFTJTUFNBTUPUBMNFOUFBVUPNBUJ[BEPTMPDBMJ[BEPTFOBUNØTGFSBTQPUFODJBMNFOUFFYQMPTJWBTIBTUBMPTNFEJ EPSFTNÈTCÈTJDPT REPRESENTADAS EXCLUSIVAS PARA ESPAÑA: %FTEF,/*$,EFTBSSPMMBFO#FSMÓOQSPEVDUPTEFMBNÈTBMUBDBMJEBEZ UFDOPMPHÓBQBSBDVCSJSMBTEFNBOEBTNÈTFYJHFOUFTEFGPSNBFGJDJFOUF &MQSPHSBNBNÈTDPNQMFUPQBSBBOÈMJTJTEFQ)SFEPYDPOEVDUJWJEBEZPYÓHFOP EJTVFMUPNFEJBOUFBOBMJ[BEPSFTUSBOTNJTPSFTZDPNVOJDBDJPOFTEJHJUBMFT)"35 1SPGJCVTP'JFMECVT/FOJOTUSVNFOUPT"5&9 5BNCJÏOTJTUFNBTBVUPNÈUJDPTTJOJOUFSWFODJØOIVNBOBQBSBMBNÈTBMUBTFHVSJEBE 4FOTPSFTEFQ)SFEPYDPOEVDUJWJEBEZ0YÓHFOPEJTVFMUPQSPEVDJEPTFO4VJ[B DPOMPTFTUÈOEBSFTEFDBMJEBENÈTBMUPT 4PODPOPDJEPTQPSTVFYUSFNBQSFDJTJØOBMUBDBMJEBEMBSHBWJEBÞUJMZSFOEJNJFOUP JONFKPSBCMFFOVOBBNQMJBHBNBEFBQMJDBDJPOFTBTJDPNPTVSFTJTUFODJBBMPT QSPDFTPTCJPUFDOPMØHJDPTTJFOEPFMFMFDUSPEPRVFTPQPSUBFMNBZPSOÞNFSPEF FTUFSJMJ[BDJPOFTEFMNFSDBEP &TQFDJBMJTUBNVOEJBMFOTJTUFNBTEFNVFTUSFPZBOBMJ[BEPSFT%FFMFDDJØOFO JOEVTUSJBEFFOFSHÓBZBMJNFOUBSJBBEFNÈTEFFRVJQBNJFOUPQBSBJOUFHSBEPSFT &RVJQPTEFNFEJEBEFUVSCJEF[DMPSPZEFSJWBEPTOJWFMZDBVEBMBOBMJ[BEPSFT EFQ)SFEPYDPOEVDUJWJEBE0YÓHFOPEJTVFMUPQBSBBHVBT 70 www.labprocess.es