DRIVER 230 CPL
DELTA DORE - Bonnemain
35270 COMBOURG - FRANCE
E-mail : deltadore@deltadore.com
Device complying with the requirements of the directives: 2004/108/CE (electromagnetic compatibility)
and 2006/95/CE (low voltage safety).
*2701972_Rev.1*
3 zone weekly programmer using power
line carriers
Contents
Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General principle . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Starting up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Price programming . . . . . . . . . . . . . . . . . . . . . . . . 12
Wireless option . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Associating a door/window magnetic contact ........... 14
Associating a TYXAL alarm control unit.................... 15
Associating a TYDOM 200 remote control................ 16
Associating a TYXIA remote control ......................... 17
Associating a telephone transmitter
TYDOM 300 .............................................................. 19
Deleting all wireless associations.............................. 19
Characteristics
• 230 V, 50 Hz power supply, ±10%
• Clock back-up in the event of mains outage: 4h (per
condenser) Programming saved permanently
• Power consumption: 4 VA
• Class II insulation
• Operating mode selector knob (9 positions)
• Selection of 4 continuous modes (Frost Protection,
Economy, Comfort, Shutdown) and 1 customizable program by day and by zone
• Override with automatic return
• Programmable (1 to 99 days) or
continuous frost protection
• Carrier frequency: 132.5 kHz, FSK modulation, X2D protocol
• Compliant with the NF EN 50065 standard, class 122
• "Home" addressing: 65000 factory-coded combinations
• Digital display
• Room unit: 124 x 95 x 43 mm
• Wall mounting on flush-mounted box or projecting
• Protection index: IP 30
• Installation in an environment with normal pollution levels
• Compatible with the TYDOM 520 for adding home automation functions
• Operating temperature: 0 to 40°C
• Storage temperature: -10°C to +70°C
Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore.
-3-
General principle
Power line carrier transmission
The principle of “PLC” transmissions is to stack an encoded
signal with a higher frequency and weaker amplitude on the
signal present between the live and neutral wires (230 V, 50
Hz).
Electronic
meter
CPL
ECS
OK
Marche Arrêt
Délestage
Normal
Config.
OK
Défaut
Défaut
CHAUFFAGE
DRIVER 230 CPL can be used
in blue tariff installations with
an area less than 180 m².
50 Hz
Transmitter
Carrier
frequency
GP4 CPL
1 2
Receiver
230 V mains network
N
L
N
L
DRIVER CPL
programmer
3 4
5 6
remote-info
GP4 CPL
(optional)
1 DHW output
Electric water
heater
Receivers
They are of the following types:
- TC51089 "Pilot Wire" for controlling 6-order pilot wire
convectors (GIFAM standard).
Mains supply
N
L
- X2D PLC reception circuit boards of various convector manufacturers
Convectors
zone 1
- X2D PLC radiators
The quality of the comfort temperature control depends on the
quality of the convector thermostat.
TC51089 PLC
receiver
(not supplied)
TC51089 PLC
receiver
(not supplied)
TC51089 PLC
receiver
(not supplied)
Convectors
zone 2
Convectors
zone 3
Phase coupler
In three-phase installations, you must
use a phase coupler to transmit on the
3 phases simultaneously.
N
-4-
Ph1 Ph2 Ph3
-5-
Installation
Connection
Positioning options
The driver can be installed anywhere in your home. That said,
having it within reach for programming is an advantage.
- Standard UTE NF C15-100 and good practice must be complied with.
- Connected or nearby equipment must not generate excessive interference
(directives 2004/108/CE).
Switch off the mains power before handling the device.
Mounting
To mount the unit on the wall, it must be separated from its
base.
Once separated from the case, the base must be wall-mounted with screws and plugs or installed in a flush-mounted box
(distance between centres 60mm) using the ➊ holes.
Knockout partitions are provided for passing the connection
wires (➋ : for flush-mounted box, ➌ : for wall-mounting)
Connect the two power leads to the
terminal.
Replace the device on its base and
attach it with the tightening screw.
For a projecting mounting, the cable
(2 wires, class 2) must reach the unit
via a cable duct.
Switch on the installation.
2
3
When the installation is switched on for the first time, the
display will only appear after around 30 sec. (back-up
capacitor charging period). Only an hourglass flashes at
this time.
Note: To protect the DRIVER CPL power supply, you must
use a 10 A circuit breaker at least (do not use a 2 A circuit
breaker).
-6-
-7-
Starting up
Startup mode enables the PLC products to be combined
amongst themselves and the installation organisation to be
determined (transmitters, receivers, pilot wire type, load shedding, etc.).
Note: You may only define one type of pilot wire for each zone.
1
On the DRIVER 230 CPL, you can associate a “PLC transmitter” type device (GECPL1, GP4 CPL, TYPHONE 2 CPL,
etc.). Otherwise, confirm to move onto the next step 4
Enter startup mode.
The unit displays “EMET” alternating with
“----”.
Turn the knob to
.
Set the clock if necessary (see user guide)
or press
to move onto the next step.
The unit displays PArA.
2
Associating Driver 230 with
a transmitter
3
Determining the type of pilot wire
Press the
and
buttons simultaneously.
The unit displays FP4 (4-order pilot wire) or
FP6 (6 order pilot wire) for zone 1.
Press the
and
buttons to determine
the type of pilot wire used, then press
validate.
Repeat the operation for zones 2 and 3.
to
• To associate an energy manager type transmitter
(GECPL1, GP4 CPL, etc.)
Confirm on the transmitter (see the relevant
guide).
The display reads GE--.
Note: Press
Z1
Z2
Z3
to cancel.
• To associate a PLC telephone remote control type transmitter (TYPHONE 2 CPL)
Confirm on the transmitter (see the relevant
guide).
The display reads --TL.
Note: Press
to cancel.
If DRIVER 230 CPL is associated with 2
types of transmitter, the display reads GETL.
Press
to confirm your choice and move
on to the next stage.
-8-
-9-
Starting up
4
Allocation of receivers
You must associate each receiver to the central control unit
and you can determine the load-shedding channel to which it
is allocated (if DRIVER 230 CPL is associated with an
energy manager: GECPL1, GP4 CPL, etc.).
4.1 The unit is associated with a GECPL1, GP4 CPL, etc.
➊ Press
or
to select the load-shedding channel to
which the receivers will be allocated.
The load-shedding channel can be selected from d:0 to d:6
(d:0 = no load shedding).
For use with GECPL1, channels d4, d5 and d6 must not be
allocated (no load-shedding).
Selecting the
load-shedding channel
4.2 The unit is not associated with a GECPL1, GP4
CPL, etc.
The "EMET" screen flashes.
Indication of the
relevant heating
zone
Z1
Z2
➊ Confirm on the zone 1 receivers
➋ Press
. The unit goes to zone 2.
➌ Confirm on the zone 2 receivers.
➍ Press
. The unit goes to zone 3.
➎ Confirm on the zone 3 receivers.
➏ Press
to confirm and exit the mode.
Z3
➋ Confirm on the relevant receivers.
➌ Repeat operations ➊ and ➋ for the receivers allocated to
another load-shedding channel
to confirm your selection and move onto zones 2
and 3. Repeat the operation.
➎ Press
to confirm and exit the mode.
➍ Press
- 10 -
Z3
The identification of the relevant heating zone is displayed.
Indication of the
relevant heating zone
Z1
Z2
- 11 -
Price programming (only in tempo option)
The Driver 230 CPL must be combined with a GECPL1 or
GP4 CPL energy manager.
Price programming is used to select a lower temperature
(economy) in periods when electricity is most expensive (e.g.
peak hour period, Red day).
Prices are programmed using the programs of the electronic meter.
BLUE day
Off-peak
Hours
Peak
Hours
WHITE day
Off-peak
Hours
Peak
Hours
CHAU 0
CHAU 1
CHAU 2
RED day
Off-peak
Hours
Peak
Hours
Operating Mode Applicable in Economy
Periods
Turn the knob to
Press
to display PArA.
Press again
setting mode.
to enter the price reduction
Z1
to validate and move onto zones 2 and 3
Repeat the operation, then confirm with
CHAU 4
The unit displays the time.
CHAU 5
CHAU 6
CHAU C
Period with active price reduction
- 12 -
Z2
Z3
➊ By pressing the
or
buttons, select the mode desired
for a price reduction in zone 1 (Economy, Comf -2°C, Comf
-1°C, Comfort (no reduction)).
Note: The Comfort -1°C and Comfort -2°C modes are only
available with 6-order pilot wire heating.
➋ Press
CHAU 3
.
- 13 -
.
Wireless option
The TYDOM 520 wireless module lets you associate the following home automation functions:
- operation with a door/window magnetic contact,
- operation with a TYXAL alarm central control unit
- operation with TYXAL remote controls (Delta Dore),
- operation with a home automation transmitter (example:
TYDOM 300).
Installing the module
Switch off the mains power
before handling the device.
Note: it is possible to associate up to 16 home automation
products (detectors, emitters, etc.).
Associating a TYXAL alarm control unit
p
To associate your Driver CPL with a
door/window magnetic contact
On the Driver CPL, set the selector to
Beeep1
Open the battery
cover of the
control unit
Beee
1234
567
Associating a door/window magnetic
contact
- 14 -
Repeat the association operation to associate another
door/window magnetic contact.
To set the control unit to “Maintenance” mode.
Simultaneously press the ON and OFF buttons on the remote
control for 5 seconds and open the control unit cover.
Separate the unit from its base.
Put the module in its place.
Close up the unit.
and press and hold the
button for 5 sec.
The unit displays rAdio.
On the receiver, press the test key (it emits a
beep).
On the Driver CPL,
rAdio is no longer displayed.
The door/window magnetic contact is
associated with the Driver CPL.
5 sec.
To associate your Driver CPL to a TYXAL alarm central
control unit, turn the selector to
and
press and hold the
button
for 5 sec.
The unit displays rAdio
Press the Test button of the control unit.
Check that rAdio is no longer displayed on the screen
The central control unit is associated with the Driver CPL.
- 15 -
Wireless option
Associating a TYDOM 200 multifunction
remote control
To associate your Driver CPL with a
TYDOM 200 remote control
On the Driver CPL, set the selector to
and press and hold the
button for 5 sec.
The unit displays rAdio
On TYDOM 200,
- if the TYDOM 200 remote control screen is not displayed,
press one of the domain butP
, BEE
tons,
BEEP
home
- press the home domain button until the remote control
transmits one beep and the
3 sec.
- press on one of the tactile
comfort
or economy
buttons of the TYDOM 200
remote control.
and
buttons of the TYDOM 200.
On the Driver CPL, set the selector to
the
button for 5 sec.
The unit reads rAdio.
On the TYDOM 200, press on
one of the tactile
shutdown or
automatic buttons
on the remote control.
BEEP
Associating
shutdown and
automatic
modes
On the Driver CPL, rAdio is no longer displayed.
The
and
buttons of the TYDOM 200 remote control
are associated with the Driver CPL.
Associating
comfort and
economy
modes
P
, BEE
BEEP
On the Driver CPL, rAdio is no longer displayed.
The
and
buttons of the TYDOM 200 remote control
are associated with the Driver CPL.
- 16 -
and press and hold
To exit association mode, press another domain button (e.g.
lighting
).
symbol flashes,
BEEP
To associate the
- 17 -
Lighting
Wireless option
Associating a TYXIA remote control
To associate your Driver CPL with a TYXIA remote control.
On the Driver CPL, set the selector to
and press and hold the
button for 5 sec.
The unit displays rAdio.
On the transmitter, press and hold down the
and
buttons together for about 5 seconds.
The buttons will light up, go out, then light up again. Release.
On the Driver CPL, rAdio is no longer displayed.
The emitter’s
and
buttons are associated with the
Driver CPL. They allow for a Comfort or Economy override.
Associating a TYDOM 300 telephone
transmitter
To associate your Driver CPL with a TYDOM 300 telephone
transmitter
On the Driver CPL, set the selector to
and press and
hold the
button for 5 sec.
The unit displays rAdio.
On the TYDOM 300 (transmitter),
press the button on the top of the unit.
The transmitter emits 3 confirmation
beeps.
Check that rAdio is no longer displayed
on the screen.
The TYDOM 300 transmitter is associated with the DRIVER CPL.
Deleting all the wireless product associations with the Driver CPL
On the DRIVER CPL, set the selector to
and hold the
button down for 10 sec., until the time is displayed (the
DRIVER CPL displays rAdio after the button is held down for
5 sec.).
All wireless product associations are deleted.