Client Project Project Reference Date and Engineer Bolt Tensioning Datasheet Flange Specification Ident Joint Information Nom Thread Size TPI Num Bolts Bolt to Tensioning Ratio Load Transfer Factor LTF Clamp Length Tensioning Tool Information Proposed Tensioning Tool Tool Pressure Area RN Bolt Information Bolt Material Bolt Yield Strength Stress Area Bolt Length Torque Information Torque K Factor Load information 17/02/2020 24 x 900 ANSI ANSI B16.5 & MSS-SP44 NEW APPLICATION 2,1/2"-8UN 8 Flange Configuration F1 155,60 WN-RTJ F2 155,60 WN-RTJ In 321,20 In2 8489,95 20 Gap 1,2077 12,646 Ws 50% CTST-04 13,159 ASTM A193 - B7 105152 lb/in2 20,52 In 4,459 4165,01 0.16 lbs/in2 Proposed Tensioning Tool In2 ft.lb Bolt Stress 10 mm Tensioner mm2 725 N/mm2 521,2 mm 2876,77 5647,00 N/mm2 Pass Bolt # Pass 1 1 13761 949 1 11467 791 Pass 2 Pass 3 mm2 Applied Pressure 2 psi 11467 bar 791 Pass 4 Checking Pass Pass 1 N.m Pass 1 Tons Bolt Load 1 11467 791 % of Bolt Yield kN % T1 @ A Pressure 40611 280,00 80,84 805,50 38,6 T2 Residual 28022 193,21 55,78 555,81 26,6 T1 @ B Pressure Stress @ Detensioning Tensioning Pressures 100% Tensioning Pressures 50% Tensioning Pressures Max Detensioning Pressures 33842 psi 11467 13761 233,33 1st Pass 67,37 Bar psi 949 11467 791 - 671,25 2nd Pass 32,2 % of Bolt Yield Bar % - 32,2 791 38,6 Stresses based on Bolt Tensile Stress Area (BS1580 / BS3643). Torque calc based on NUT FACTOR (K= 0.16) 'An introduction to the Design and Behaviour of Bolted Joints' Bickford, p. 233. Application Comments Max Detensioning Pressure refers to the maximum capacity of the tensioning tool and should not be considered to be the safe max load capacity of the flange 100% Tensioning is the recommended mode of bolt tensioning, wherever possible use 100% Bolt to tool ratio © 2020 Tentec Limited Tentec Limited do not accept any liability for errors within or caused by the use of this software. - All Rights Reserved