Subido por Jhonny Silva

OPTIMUS COMPACT EN

Anuncio
EN54 IP Networked System
PUBLIC ADDRESS
AND VOICE ALARM
FEATURES
• Alarm, prerecorded and live messages.
• Music broadcasting.
• Management of speaker zones.
• Microphone desks connected by bus or
through the corporate data network.
• Reception of 4 simultaneous digital
audio channels via IP connection.
• Output/input contacts for emergency
functions, message activation, zone
control ...
• Audio outputs with individual volume
control.
• Critical path supervision: speaker lines,
amplifiers, cards, power, contacts,
prerecorded messages ...
• Call point software for live or prerecorded
messages, alarm notification ...
• PC integration (XML) and direct
integrations (JSON, SNMP, API/DLL).
• Control data reception and transmission
via IP connection.
• Compatible with SIP protocol.
• Linked systems through corporate
network and accessible from IP points
(microphones, SIP phones ...).
• Double Ethernet connection (Layer 2 & 3)
and double power supply input for
redundant installations.
• Operation over the Internet via VPN
FEATURES
Suitable for both centralized or distributed systems, scalable and modular,
for infrastructures of any type and size, linked through the corporate data network.
DIAGRAM
Audio inputs
Volume control
Fire Alarm System
integration
Analog Control
microphones
Noise sensors
IP microphones
Speaker areas
SIP compatibility
IP audio channels
High capacity
Network connection
Global control
AoIP layer 2 or layer 3
EQUIPMENT
COMPACT
Audio matrix (main unit) with IP connection
With Input/Output contacts card UMX-C16 and
audio input card UMX-EA3.
With 8 free slots to insert cards
UMX-C16 | UMX-EA3 | UMX-2M3
UMX-2SA | UMX-MC6 | UMX-2SB*
Up to 20 COMPACT networked
COMPACT-E
Expansion unit
With 10 free slots to insert cards
UMX-2SA | UMX-MC6 | UMX-2SB*
Up to 10 COMPACT-E (each COMPACT)
EQUIPMENT
COMPACT
Includes power supply and control module
1 – ETH A connector
2 – ETH B connector (redundant network)
3 – CAN bus for microphones and noise sensors
4 – FAIL contacts (system alarms)
5 – GND
6 – Input contacts (3), supervised
7 – Output contacts (3)
8 – Main power supply
9 – Secondary power supply (redundant)
10 – Audio bus expansion (to COMPACT-E)
11 – Main power supply fuse
12 – Secondary power supply fuse
13 – Grounding
EQUIPMENT
UMX-C16
I/O contacts card
16 input contacts with possibility of supervision.
4 output contacts (dry contact or referred to ground).
EQUIPMENT
UMX-EA3
Card with two audio inputs
Audio level adjustment.
Possibility to pre-set the zones for each input
Priority by PTT or VOX
Signal of activated zones (ACK)
Configurable sensitivity
0 dB | -20 dB | -60 dB | -60 dB + speechfilter
EQUIPMENT
UMX-2M3
Card with two music audio inputs
Stereo RCA connectors; internal sum of the L and R
• Audio level adjustment
• Configurable sensitivity via software
AUX H (775 mV) and AUX L (100 mV)
EQUIPMENT
UMX-2SA
Card with two audio outputs
2 x 0dB / 600 Ohm and priority (RJ45)
Up to +4dB for ProSound power units
Fault detection and indication in amplifier or speaker lines
Transformer balanced outputs
Volume control from front panel or remote device
Fault detection and indication in amplifier or speaker lines
Bass / treble equalization or 10 bands
EQUIPMENT
UMX-MC6
Card with 6 speakers subzone outputs
Security paging
Compatible with 3 or 4 wire attenuators
Double 100 V input
channel I (music)
Channel II (paging and/or backup).
A/B zones configuration
EQUIPMENT
UMX-2SB*
Card with speakers subzone outputs (4, 8, 12 or 16)
2 balanced audio outputs directed to 4, 8, 12 or 16
sub-zones (depending on the model)
Individual volume adjustment in music program subzones
Volume control from front panel or remote device
Double 100 V input: channel I (music) and channel II
(warnings and / or backup)
Speaker lines and power units measurement
Sub-zones outputs with security paging
*UMX-2SB1: 4 subzones
UMX-2SB2: 8 subzones
UMX-2SB3: 12 subzones
UMX-2SB4: 16 subzones
A/B zones configuration
Bass / treble equalization or 10 bands
SPEAKERS ZONES
1 x COMPACT
10 x COMPACT-E
A | Individual alarm
and music volume
control
B | Individual music
volume control and
general alarm volume
control
108 x UMX-2SA
22 x UMB-2SB
C | General alarm and
music volume control
1 x UMX-2SA
107 x UMX-MC6
216 zones
352 zones
642 zones
EXAMPLES
UMX-2SA
Card with two audio outputs
UMX-2SA
Up to 8 cards in COMPACT
Up to 10 cards in COMPACT-E
Individual voice volume control
Individual music volume control
Voice & music
Voice & music
EXAMPLES
UMX-2SA + UMX-MC6
Card with two audio outputs
Card with subzone outputs
UMX-MC6
Multiple combinations
n x UMX-2SA
m x UMX-MC6
n+m ≤ 108
UMX-2SA
General voice volume control
General music volume control
1
2
6
Voice
Music & backup
EXAMPLES
1
UMX-2SA + UMX-MC6
UMX-MC6
Card with two audio outputs
Card with subzone outputs
1 x backup for several zone
amplifiers
Voice & music
6
UMX-2SA
Voice & music
1
UMX-MC6
UMX-2SA
Backup
2
2
6
EXAMPLES
UMX-2SB4
Card with subzone outputs
1
General voice volume control
Individual music volume control
UMX-2SB4
Up to 2 cards in COMPACT
Up to 2 cards in COMPACT-E
2
16
Voz
Música y backup
EXAMPLES
UMX-2SB
Card with subzone outputs
1A
Up to 2 cards in COMPACT
Up to 2 cards in COMPACT-E
A + B mode
1B
UMX-2SB
General voice volume control
Individual music volume control
8A
8B
Voz
Música y backup
EXAMPLES
COMPACT + 2 x UMX-2SB
COMPACT-E + UMX-2SB + UMX-2SA + (UMX-2SA + 4 x UMX-6MC)
74 zones
MICROPHONES
ME-200B
Fireman's panel with microphone
Emergency message board.
For evacuation in case of fire or similar
circumstances
With handheld microphone for sending live
announcements
Controls to activate emergency mode and send
pre-recorded warning and evacuation messages.
Ready to be installed on the front of the
COMPACT audio matrix
MICROPHONES
MD-30ETH | MD-30C
Microphone desk “local”
18 configurable keys
sending messages to individual zones,
groups of zones.
Ethernet connection (MD-30ETH)
Bus connection (MD-30C) max 16
max 4
MICROPHONES
DC-700ETH
Microphone desk “global or “local”
Live recording or pre-recorded messages
broadcasting through the Ethernet network
Supervision of the PA/VA system
Configuration of parameters.
Fireman’s microphone functions
Equivalent to a VACIE remote control unit.
Sending notifications to zones / groups.
Activation of pre-evacuation and evacuation prerecorded messages
(EN 54).
Activation of generic prerecorded messages
Live announcements, with or without warning tone (gong).
Music source connection and music program sending via Ethernet.
Monitor speaker
Alarm led
System alarm list.
MICROPHONES
ME-200C
Fireman's remote panel with microphone
Remote equipment for sending emergency messages
For evacuation in case of fire or similar circumstances
Safety key
Push buttons to activate the emergency mode.
It incorporates warning microphone.
POWER UNITS
DA-500D2 | DA-500D4
Digital class D power units
Digital power unit with 2 or 4 outputs of 500 W of RMS power at 100V. High
energy efficiency and minimum heat generation (class D)
Reduction of the rack space required
Voltage, current and temperature monitoring and protection circuits
 Automatic disconnection to avoid possible overload, short circuit or
overheating
POWER SUPPLY
MS-150
Power supply and switchover to emergency power
supply (batteries not included)
LC-XB12100P
Sealed Pb battery
12 V DC, 100 Ah
Rack format (19”)
Monitoring the presence of the battery and its
impedance
Protects the battery from temperature variations
Alarm messages via voltage-free contacts
Up to 6 outputs for amplifier and 3 auxiliary outputs,
protected by fuse
All connectors are plug-in
Built-in lightning protection
IP INTERFACE
IF-704ETH | IF-722ETH
IF-704ETH
IF-722ETH
=
COMPACT
+
2 x UMX-SA
=
COMPACT
+
UMX-EA3
+
UMX-SA
Interface for connecting power units anywhere in the
network
It receives messages from global IP microphone desks and
SIP telephones of a COMPACT system, as well as the general
music channels
UBS frontal input for music
It has 16 GB for storing audio messages
1
20
2
19
NOISE SENSOR
NS-CAN
Noise sensor
Bus connection, up to 16 units
Sending the noise level measured in the particular location
where it is placed
Automatic adjustment of the volume of each zone according to
the ambient noise.
Microphone capsule in a weatherproof housing
It’s possible to assign one or several sensors to one zone
It’s also possible to assign a different weight to each sensor.
Opcionalmente puede conectarse un micrófono externo
SOFTWARE
SCM-01
Setup and control software
“call point”
SCIN-01
integration software
COM-PAM
PA/VA server 24/7
COM-PCC
PA/VA PC control
SOFTWARE
Call point | MENUS
File Menu
Exit
Edit menu
Screen Design
Area
Add Area
Delete Area
Rename Area
Resize Area
Zone
Add Zone
Delete Zone
Group
Add Group
Delete Group
Device
Add Device
Delete Device
Image
Add Background Image
Delete Background Image
View Meny
Event Log
Message Log
Device Status
Message Board
State Board
Information Board
Zone Status
Zoom Bar
Group Menu
New Group
Group Information
Schedule Menu
New Message Schedule
Message Time Schedule Information
New Volume Schedule
Volume Schedule Information
Messages Menu
Message Sequence/New Message Sequence
Message Sequence/Message Sequence Information
Managing prerecorded Messages (PC)
Managing prerecorded Messages (Device)
User Menu
Change User
New User
User Info
New Profile
Profiles Info
User Configuration
Options Menu
Language
General Configuration
General
Optimus Status
Log Levels
Logs Backup
Audio Settings
PA Messages Play/Record
Local Monitor / Record
Key board short cuts
User interface Configuration
Setups
Help Menu
About…
CERTIFICATE
MUCHAS
GRACIAS!!!!!!!!!
GRACIAS
THANKS
VERY MUCH
MARKETING
Descargar