DIVATOR RS4
USER MANUAL
USER MANUAL
HAZARD INDICATORS............................................................................................... 3
SAFETY NOTICE........................................................................................................ 4
TECHNICAL DESCRIPTION......................................................................................... 5
PREPARING FOR USE................................................................................................. 9
PRE-DIVE PROCEDURES........................................................................................... 11
CHECKS DURING DIVING........................................................................................ 12
DIVING IN COLD WATER......................................................................................... 13
POST-DIVE PROCEDURES......................................................................................... 13
TRANSPORT AND STORAGE.................................................................................... 14
SPARE PARTS........................................................................................................... 14
© 2014 INTERSPIRO AB, SWEDEN. THIS PUBLICATION CONTAINS OR REFERS TO PROPRIETARY INFORMATION
WHICH IS PROTECTED BY COPYRIGHT. ALL RIGHTS ARE RESERVED. INTERSPIRO® AND DIVATOR® ARE
REGISTERED TRADEMARKS OF INTERSPIRO.
THIS PUBLICATION MAY NOT BE COPIED, PHOTOCOPIED, REPRODUCED, TRANSLATED, OR CONVERTED TO ANY
ELECTRONIC OR MACHINE READABLE FORM IN WHOLE OR IN PART WITHOUT PRIOR WRITTEN APPROVAL FROM
INTERSPIRO.
CHANGES OR UPDATES TO THIS PUBLICATION MAY BE MADE WITHOUT PRIOR NOTICE.
2
U S ER M A N UA L
HAZARD INDICATORS
This manual contains hazard warnings, identified as DANGER!, WARNING! and
CAUTION!, that indicate risks and dangers that you may face while using the DIVATOR
System. These different types of hazard indicators correspond to the degree of hazard you
may encounter:
DANGER! INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL RESULT IN
DEATH OR SERIOUS INJURY.
WARNING! INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN
DEATH OR SERIOUS INJURY.
CAUTION! INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN
MINOR OR MODERATE INJURY. IT MAY ALSO BE USED AS A WARNING AGAINST UNSAFE PRACTICES.
Failure to comply with the instructions highlighted by the hazard warnings may result in
equipment malfunctioning, serious injury or death.
3
SAFETY NOTICE
WARNING! BEFORE USING THE DIVATOR RS4 SCUBA, THE USER MUST HAVE RECEIVED FULL TRAINING IN
ITS USE, HAVE READ AND UNDERSTOOD THESE OPERATING INSTRUCTIONS AND DEMONSTRATED PROFICIENCY
TO A RESPONSIBLE TRAINER OR SUPERVISOR. FAILURE TO DO SO MAY RESULT IN INJURY OR DEATH FOR THE
USER AND CAN HAVE SERIOUS CONSEQUENCES FOR PEOPLE TO BE RESCUED AND/OR ITEMS OF VALUE TO
BE SAVED.
OWNER'S AND USER'S RESPONSIBILITIES
WARNING! INTERSPIRO IS NOT RESPONSIBLE FOR:
• COMBINATIONS OF PRODUCTS, UNLESS PUT TO MARKET BY INTERSPIRO
• CHANGES OR ADAPTATIONS MADE TO THE PRODUCT BY A THIRD PARTY.
DANGER! ALL USERS OF THE DIVATOR SYSTEM MUST BE CERTIFIED BY A NATIONALLY OR INTERNATIONALLY
RECOGNIZED SCUBA CERTIFICATION AGENCY. FURTHERMORE, ALL USERS OF THE DIVATOR SYSTEM MUST BE
ADEQUATELY TRAINED IN ITS USE BY A CERTIFIED SCUBA INSTRUCTOR WITH KNOWLEDGE AND EXPERIENCE IN
THE USE OF THE DIVATOR DIVING SYSTEM.
WARNING! HIGH PRESSURE GAS SYSTEMS MUST BE HANDLED WITH CARE. DAMAGE TO HIGH PRESSURE GAS
SYSTEM COMPONENTS MAY RESULT IN INJURY OR DEATH. INTERSPIRO IS NOT LIABLE FOR DAMAGES INCURRED
AS A CONSEQUENCE OF FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL.
WARNING! ALL USERS OF THE DIVATOR SYSTEM MUST PERIODICALLY UNDERGO TRAINING IN EMERGENCY
PROCEDURES IN SHALLOW WATER TO MAINTAIN PREPAREDNESS IN THE EVENT OF AN ACTUAL EMERGENCY.
WARNING! THE BREATHING AIR SHALL MEET THE REQUIREMENTS FOR BREATHABLE AIR ACCORDING TO EN
132 ANNEX A, OR SIMILAR PURITY REQUIREMENTS.
4
TECHNICAL DESCRIPTION
2
1
7
4
6
8
9
3
5
DIVATOR RS4 REGULATOR ASSEMBLY
1.
Regulator, first stage
2.
Anti-freeze device (maintenance free)
3.
Pressure gauge displaying pressures from 0 to 300 Bar, or 0 to 4350 Psi
(photo shows pressure gauge with optional compass and depth gauge.)
4.
High pressure hose
5.
Quick connector for DP1 with protective rubber cap (optional)
6.
Dry suit hose (optional)
7.
Octopus hose (optional)
8.
BC hose (optional)
9.
Breathing hose for full face mask or breathing valve with mouth piece (optional)
5
DIVATOR RS4 ADVANTAGES
The RS4 regulator is designed to make your dive efficient and safe. It has a high air flow
capacity that ensures sufficient air supply to the primary and the secondary (octopus)
breathing valve at the same time, regardless of the depth of the dive. This makes the RS4
an ideal regulator for professional diving and rescue missions.
MODULAR
The RS4 has a range of versions with different covers to choose from. Choosing the right
regulator configuration for your specific diving needs will give you a safe and functional
dive.
ANTI-FREEZE
The unique anti-freezing device on the RS4 is designed by Interspiro´s engineers to be dry
in all conditions, this will eliminate problems like freezing and free-flowing which other
regulators on the market may encounter. This is possible because the regulator´s reference
chamber is kept dry by high pressure gas (high pressure gas can only contain negligible
amounts of moist) and has a overpressure which ensure that no water may enter the
reference chamber.
ADJUSTABLE COVERS
Loose hanging or protruding hoses are a huge safety risk. The RS4 has adjustable covers
that makes it possible to adjust the hoses to lie secure, near the divers body, this will make
the dive more ergonomic and safe.
ROBUST SHOCKPROOF DESIGN
The RS4 has an outer shell made of durable black rubber that protects the regulator from
accidental impacts or chocks. This shockproof design will keep the regulator in a good
condition and prolong its usage time.
INCREASED USAGE POSSIBILITIES
The RS4 can be used together with both a single cylinder and a cylinder pack. This ensures
that you always have a regulator that suits your needs. A perfect match is to combine the
RS4 with Divator LITE which is a perfectly balanced cylinder pack. Divator LITE has a low
profile that allows for safer access to confined spaces and minimizes resistance in current
waters together with being the lightest diving cylinders in the world.
USING RS4 TOGETHER WITH INTERSPIRO DIVATOR DP1
The DP1 is a truly light weight and portable surface supply that provides full cylinder
pressure to the diver at depth. Using DP1 together with RS4 will give the diver even more
security when diving in tough conditions. The DP1 supply hose can be used as a lifeline
and if using a communication, it can be attached to the hose.
DIVATOR RS4 REGULATOR VERSIONS
The RS4 Regulator is available with DIN or YOKE connection, both versions are available
in four configurations. The DIN version are equipped with a parking spot plug for keeping
the dust cover in place during the dive.
6
2-PORT SCUBA (DRY SUIT/BC)
The RS4 regulator, 2-port SCUBA, is intended as a regulator to be used as an Inflation
regulator for a dry suit and/or for a BC as a “stand alone” unit with a separate small
cylinder.
Delivered without pressure gauge and
hoses. The RS4 regulator has two HP
outlets (7/16”) for a pressure gauge or
a Divator HUD. There are two LP outlets
(3/8”) for a dry suit and/or a BC hose (or
it can be used for any other LP hose). One
outlet is equipped with an over pressure
valve (tightened to 8 Nm) and the other is
equipped with a blank plug. The two HP
outlets are fitted with a blank plug and a
parking plug. (YOKE outlet on image)
2-PORT SCUBA + DP1
The RS4 regulator, 2-port SCUBA + DP1, is intended as a regulator to be used as a
“commercial SCUBA” regulator where the user would need a surface supply air connection
for the DP1 system, a breathing hose for his full face mask and an inflation hose for a dry
suit.
Delivered with a pressure gauge showing
Bar or Psi and a DP1 surface supply
connection. The RS4 regulator has one free
HP outlet (7/16”) that for example can
house the HUD or any other HP device.
The two LP outlets (3/8”) can be used for
the breathing hose for the diver, a dry suit
and/or a BC hose (or it can be used for
any other LP hose). Both LP outlets are fitted
with blank plugs. The second HP outlet is
fitted with a parking plug. (YOKE outlet on
image)
4-PORT SCUBA
The RS4 regulator, 4-port SCUBA, is intended as a regulator to be used as an ordinary
SCUBA regulator, where the user would need to connect a breathing hose for the full face
mask or breathing valve, an octopus hose, an inflation hose for dry suit and a BC inflation
hose at the same time.
Delivered with a pressure gauge showing
Bar or Psi. The RS4 regulator has one free HP
outlet (7/16”) that is fitted with a parking plug
and for example can house the HUD or any
other HP device. There are four (4) plugged LP
outlets (3/8”) that for example can house the
breathing hose for the diver, a octopus, a dry
suit and a BC hose (or it can be used for any
other LP hose). (DIN outlet on image)
7
4-PORT SCUBA + DP1
The RS4 regulator, 4-port SCUBA + DP1, is intended as a regulator to be used as
a “Professional SCUBA” regulator, where the user would need a surface supply air
connection for the DP1 system, a breathing hose for the full face mask, an octopus hose for
possible under water rescue operations, an inflation hose for the dry suit and a BC inflation
hose at the same time.
Delivered with a pressure gauge showing Bar or Psi and a DP1 Surface Supply connection.
The RS4 regulator has one free HP outlet
(7/16”) that is fitted with a parking plug
and for example can house the HUD or
any other HP device. There are four (4)
plugged LP outlets (3/8”) that for example
can house the breathing hose for the diver,
a Octopus, a dry suit and a BC hose (or
it can be used for any other LP hose) (DIN
outlet on image).
8
PREPARING FOR USE
The RS4 SCUBA can be used in different configurations. Follow this chapter in applicable parts.
ADJUSTING THE DIVATOR RS4 BEFORE FIRST USE
Adjust the RS4 into a mode that suits your SCUBA configuration before the first dive.
Use the included 2 mm (5/64 inch) hexagonal (Allen) key.
•
Turn the screws anti-clockwise maximum 1 turn until it is possible to turn the head(s).
•
Turn the head(s) into desired position.
•
Tighten the screws until the head(s) become locked in their position(s).
•
Make sure that the screws are tightened evenly.
Photo shows traditional regulator hose
mounting.
Photo shows “parallel” regulator hose
mounting.
ASSEMBLING THE DIVATOR RS4 ON THE CYLINDER
Assemble the RS4 regulator onto the high pressure outlet on the cylinder, either in the
“parallel” mode or in the traditional “standard” SCUBA mode (as seen on pictures).
Photo shows traditional SCUBA mode.
Photo shows “parallel” mode.
ATTACHING A DEVICE TO THE SECOND HIGH PRESSURE OUTLET
It is possible to attach a HUD or other HP device to the second high pressure outlet fitted
with a parking plug. Interspiro recommends that this is done by an Interspiro certified
service technician.
1.
Remove the parking plug with a 6 mm hexagonal key.
2.
Attach the HP device according to it´s manual.
When detaching the HP device: reassemble the parking plug with a 6 mm hexagonal
socket fitted on a torque wrench to 15 Nm.
9
ATTACHING AND DIRECTING HOSES ON DIVATOR BC
USE OF INTERSPIRO HOSES
If using Interspiro hoses, tighten the hoses to 10 Nm.
USE OF OTHER HOSES THAN INTERSPIROS
Make sure that the hose has a working pressure of at least 34 Bar (490 Psi) and a burst
pressure of at least 100 Bar (1450 (Psi). Tighten them according to the hoses user manual.
CONNECTING THE BREATHING HOSE
Connect the breathing hose to the full face mask (or mouthpiece) by screwing it on
fingertight. If an over pressure mask is fitted, close the lever.
CONNECTING THE INFLATION HOSE
1. Put the inflation hose for the BC through the upper elastic band on the corrugated
inflation hose.
2.
Pull the hose until you can connect it to the power inflators connector.
3.
Adjust the hose length so that both hoses are parallel. Fasten the inflation hoses with
the left velcro holder on the BC.
CONNECTING THE OCTOPUS BREATHING HOSE AND VALVE
1. If a breathing hose for octopus is fitted, put the hose through the right inner side of the
BC bladder and pull it out in its full length.
2.
Connect the hose to the octopus breathing valve by screwing it on finger tight.
Close the Lever on the octopus breathing valve.
3.
Bend the hose one third of the length from the regulator. Insert the bent section of the
hose through the elastic cord located on the upper back part of the BC harness.
4.
Connect the octopus breathing valve to the octopus mouthpiece holder (optional) in a
suitable position or store it in the BC´s right outer pocket.
ATTACHING THE DRY SUIT INFLATION HOSE
If a dry suit inflation hose is fitted, put it through the right inner side of the BC harness.
ATTACHING THE RS4 REGULATOR PRESSURE GAUGE
Fasten the elastic cord with hook (attached on the pressure gauge) on a suitable D-ring on
the BC. Make sure it is easily accessible during the dive.
DIRECTING THE DIVATOR DP1 HOSE
If the DP1 hose is fitted, make sure it is directed through the left inner side of the BC
bladder. Store the DP1 hose in the BC left outer pocket. Close the zipper if you are not
performing a DP1 surface supply dive.
SURFACE SUPPLY DIVING USING THE DIVATOR DP1
1. Before using the DP1 Surface Supply diving system together with the RS4 SCUBA
make sure that the attendant has:
10
•
connected the air cylinders
•
done the pre-dive checks on the DP1 equipment
•
checked that air is fed to the DP1 regulator according to the DP1 manual.
2.
Connect the RS4 quick connector for DP1 to the DP1 regulator.
3.
Tighten the locking ring fully. Loosen it a quarter of a turn.
4.
Put the DP1 Surface Supply assembly in the left BC pocket for security and protection.
5.
Close the zipper on the BC pocket to avoid the regulator from falling out during diving.
6.
Connect the carabiner on the DP1 surface supply hose to the lifebelt worn by the diver.
For further instructions see the DP1 user manual.
PRE-DIVE PROCEDURES
OVERALL CHECK
1.
Make sure that the RS4 regulator is clean and free from sand and/or debris from
previous use.
2.
Inspect the regulator to detect if it has any signs of damage. A damaged or defective
regulator must be replaced or repaired by an Interspiro certified service technician.
3.
Check all hoses by pulling and bending them while inspecting for damage, cracks and
discolouration. If the high pressure hose to the pressure gauge is found to be defective
or damaged, it must be replaced by an Interspiro certified service technician.
4.
Check that the protective band is attached to the reliefe valve otherwise replace it with
a new protective band. Protective band order no. 346 190 053 (10 pack).
WARNING! THE AIR LOSS CAUSED BY A BREAK IN THE DRY-SUIT HOSE IS JUST AS GREAT AS THAT CAUSED BY
A BREAK IN THE BREATHING HOSE. THEREFORE, CHECK THOROUGHLY!
The RS4 regulator has a restrictive orifice in the high pressure hose that limits the air flow to
the pressure gauge. The restriction protects the user and the equipment if the hose burst.
CHECKING O-RINGS
O-rings that are exposed to sunlight, salt water, chemicals (including mild detergents), and
ozone suffer ageing and may become defective.
1.
Check all visible O-rings.
2.
Replace all cracked or damaged O-rings.
NOTE! IF IT IS A DIN CONNECTION, TIGHTEN THE CYLINDER VALVE COMPLETELY TO PREVENT THE O-RING ON
THE REGULATOR CONNECTION NIPPLE TO COME OFF.
If using a DIN connection and the O-ring on the regulator connection nipple comes off. Put a
new O-ring on the nipple by pushing it in place. O-ring order no. 336 190 272 (10 pack).
LEAKAGE AND FUNCTION TEST OF THE DIVATOR RS4 REGULATOR
1.
Assemble the diving apparatus.
2.
If using the primary breathing valve with safety pressure lever, make sure that the
safety pressure lever is in closed position.
3.
Open the cylinder valve slowly and observe the pressure gauge. Check that the
pointer moves normally and smoothly. If the pointer moves irregularly or not at all, the
pressure gauge is faulty. When the cylinder valve is fully open, then close it a quarter
turn.
11
4.
Check the pressure gauge to make sure that there is enough air pressure in the
cylinder for the planned dive. Interspiro recommends that the cylinder should be full
before every dive.
5.
Press the inflate button on the BC inflator to make sure that it inflates the BC bladder.
Push the dump button on the inflator to make sure that it drains the BC bladder from air.
6a. If using a primary breathing valve with safety pressure, turn the safety pressure lever
to the open position. Check that a strong flow of air is heard. Reset the safety pressure
lever to the closed position.
6b. If using a primary breathing valve without safety pressure, press the purge button on the
breathing valve. Check that a strong flow of air is heard. Release the purge button.
7.
If using a octopus breathing valve together with the primary breathing valve, press the
purge button on the octopus breathing valve. Check that a strong flow of air is heard.
Release the purge button. Close the locking lever against the valve housing.
8.
Test the entire system for leaks with the following steps.
•
Close the cylinder valve.
•
Wait for one (1) minute.
•
Listen for leaks.
•
Open the cylinder valve while watching the pressure gauge.
•
Check that the needle does not rise by more than 10 Bar (145 Psi).
CAUTION! IF LEAKAGE IS GREATER THAN THE SPECIFIED VALUE, ANOTHER LEAKAGE HAS BEEN LOCATED
OR IF THE EQUIPMENT IS FOUND TO BE DEFECTIVE OR DAMAGED, THE EQUIPMENT MUST BE REPAIRED BY AN
INTERSPIRO CERTIFIED SERVICE TECHNICIAN.
9.
Close the cylinder valve.
10. Check that the pressure gauge needle moves evenly while venting the system by
pressing the purge button (or turning the safety pressure lever to open) on the
breathing valve.
CHECKS DURING DIVING
1.
Check the pressure gauge repeatedly to monitor air consumption. Terminate the dive
with ample air pressure to be able to return safely to the surface or to the entry point
of the dive.
2.
Check for leaks or abnormal behaviour of the RS4 regulator (small bubbles will
occasionally leave the anti-freeze device and are expected when ascending, this is
natural).
3.
Check that optional equipment fitted to the RS4 regulator can be reached and
managed.
4.
If using a DP1 surface supply together with the RS4 regulator, check that air is not
consumed from the worn cylinder. See the DP1 surface Supply user manual for
additional details.
WARNING: WHEN DIVING WITH THE RS4 REGULATOR THE DIVER´S ONLY WARNING OF LOW AIR PRESSURE
IS BY REPEATEDLY MONITORING THE PRESSURE DROP OF THE PRESSURE GAUGE.
WARNING: IF USING THE DP1, THE ONLY INDICATION THAT THE DIVER HAS SWITCHED FROM SURFACE
SUPPLY TO THE SCUBA CYLINDER (BAIL OUT) IS A DECREASE IN THE DIVER´S PRESSURE GAUGE.
12
DIVING IN COLD WATER
The RS4 regulator is equipped with a unique anti-freeze device that is specially constructed
for extreme cold water diving.
Cold water diving is dangerous and requires special planning, training and preparation.
Make sure that the diver and surface support have appropriate training and experience in
diving during cold water conditions before conducting a cold water dive.
POST-DIVE PROCEDURES
1.
If using the RS4 SCUBA together with the DP1 surface supply. Disconnect and vent the
DP1 according to the DP1 surface supply user manual.
2.
Pressurize the RS4 SCUBA (if not already done).
3.
Rinse all parts of the RS4 SCUBA in clean water. If the equipment is very dirty, use a
brush and a neutral cleaning agent for extended cleaning. For a detailed description
of how to clean the face mask/breathing valve and BC – see each product’s user
manual.
4.
Close the cylinder valve.
5.
Press the purge button on the breathing valve to vent the regulator. Venting may take
as long as 30 seconds. The O-ring sealing between the regulator and the cylinder
valve may be damaged if it is removed when there is pressure remaining.
6.
Remove the RS4 regulator from the cylinder.
7.
Allow all regulator parts to dry.
8.
Disconnect and dry the rest of the RS4 SCUBA equipment according to each product’s
user manual.
9.
Blow any moisture out of the cylinder valve by opening the valve and allowing air to
escape for 1 to 2 seconds.
10. Close the cylinder valve and tighten the cylinder valve plug by hand (if fitted). The
cylinder valve shall always contain a safety pressure of at least 2 Bar (29 Psi).
11. Put the dust cover on the regulator connection nipple for protection.
12. If the equipment is faulty or damaged, it must be repaired or replaced by an
Interspiro certified service technician.
13. The equipment shall be thoroughly dried if it is to be stored in a bag/box for more
than a few hours.
WARNING! BLOW-OFF NOISE AND PRESSURE SURGES MAY CAUSE HEARING DAMAGE. ALWAYS USE EAR
PROTECTORS WHEN FILLING AND EMPTYING AIR CYLINDER PACKS.
13
TRANSPORT AND STORAGE
All rubber parts shall be stored in dry conditions, well protected from direct sunlight and
extremes of temperature in a sealed plastic bag.
During transport, the equipment shall be stored so that the equipment cannot be damaged
and people cannot be injured. The cylinder (pack) must be transported with tightened plugs
and, if possible, in boxes.
The equipment shall not be stored where the temperature may be expected to go above
70ºC (158°F). The equipment must be completely dry before being put into storage.
The DIN connection is equipped with a dust cover that protects the high pressure outlet during
transport and storage. Dust cover order no. 31 392-51 (10 pack).
SPARE PARTS
Dust cover order no. 31 392-51 (10 pack)
O-ring order no. 336 190 272 (10 pack)
Protective band order no. 346 190 053 (10 pack)
14
PART NO. 32995A01
Descargar