Information contained in this document, in particular data, pictures, information, trademarks and logos are protected by copyrights and other intellectual property rights. © 2018, Diagnostica Stago, all rights reserved – 03/2018. Consequently, all representation and/or reproduction, whether in part or in full, is forbidden and would be considered a violation of Diagnostica Stago's copyrights and other intellectual property rights. Visual representations (diagrams, pictures, icons, pictograms, screenshots, spare parts, ...) are not contractual. STA Satellite Max ASTM Protocol Table of contents 1 Reference Standards ........................................................................................... 5 2 Scope.................................................................................................................... 5 3 Limitation of the document ................................................................................. 5 4 Hardware Interface .............................................................................................. 5 5 Definitions ............................................................................................................ 6 6 Standard exchanges types ................................................................................. 6 7 Instrument Setup ................................................................................................. 7 7.1 LIS Connection Setup ......................................................................................................7 8 Detailed Message and Records Description ..................................................... 9 8.1 Message Header Record .................................................................................................9 8.2 Patient Information Record ............................................................................................10 8.3 Test Order Record .........................................................................................................11 8.4 Result Record ................................................................................................................12 8.5 Comment Record...........................................................................................................14 8.6 Request Information Record ..........................................................................................15 8.7 Message Terminator Record..........................................................................................16 8.8 Scientific Record .................................................................... ...........................................17 8.9 Manufacturer Information Record...................................................................................17 8.10 Error and Flag Code Table.............................................................................................18 9 Examples of Messages sent to the LIS ............................................................ 19 9.1 Queries ..........................................................................................................................19 9.1.1 Worklist Query ................................................................................................................................ 19 9.1.2 Worklist Query Cancelled ............................................................................................................... 19 9.2 Results Upload ..............................................................................................................19 9.2.1 Patient Result Upload ..................................................................................................................... 19 9.2.2 Patient Result Upload with Alarms and Patient Information ........................................................... 20 9.2.3 Patient Result Upload – Result in Duplicate ................................................................................... 20 9.2.4 Control Result Upload .................................................................................................................... 21 0932500_EN xxxx 3/21 20 STA Satellite Max ASTM Protocol Revision table Reference 0932500_EN 4/21 Date March 2018 Description Creation 0932500_EN STA Satellite Max ASTM Protocol 1 Reference Standards The ASTM connection protocol on the STA Satellite Max is based on the two following standards: CLSI LIS01-A2 : Specification for Low Level protocol to Transfer Messages Between Clinical Laboratory Instruments and Computer System; Approved Standard - Second Edition (Previously ASTM E1381-95) CLSI LIS2-A2 : Specification for Transferring Information Between Clinical Laboratory Instruments and Information Systems; Approved Standard - second Edition (Previously ASTM E1394-97) 2 Scope This Document applies to STA Satellite Max GUI software version 1.0.18.2 and above. 3 Limitation of the document This document does not describe the ASTM communication protocol. For details about the low level and high level communication protocol details please refer the Standards referenced in section 1. Reference Standards 4 Hardware Interface The LIS communication protocol is implemented on a serial RS232 physical transport link, with following characteristics: Parameter Interface Value Serial type, standard RS232 Or via USB to serial adapter SUBD 9 - Male on the instrument (PC) side Pin 2 : Rx (Reception) Connector and pin-out Pin 3 : Tx (Transmission) Pin 5 : Ground Flow Control / Handshaking Pin 1, 4, 6, 7, 8, 9 : Not connected None Baud Rate* 110 to 115200 Bauds (19200 by default) Parity* Even, Odd, Mark, Space, None (Odd by default) Data Bit* 5, 6, 7, 8 (8 by default) Stop Bit* 1,2 (1 by default) * These parameters have to be specified in the [Software Configuration] ; [LIS settings] tab of the analyzer. estem 0932500_EN xxxx 5/21 20 STA Satellite Max ASTM Protocol 5 Definitions Term Definition ASTM American Association for Test and Material L.I.S / LIS Laboratory Information System N.T. Not Transmitted Text A string of characters in range permitted by the Standard Date-Time A string of character defining the Day, Month, Year, Hour Minute and second. N/A Not applicable NULL An empty string of characters Download (D) Transmission of data from the LIS to the Instrument Upload (U) Transmission of data from the Instrument to the LIS 6 Standard exchanges types The following exchanges are supported by the STA Satellite Max # 1 Direction Instrument LIS (U) Description Worklist Query Pattern H.Q.L H.P.O.[R.[C.].M]L 2 Instrument LIS (U) 3 LIS Instrument (D) Worklist download H.P.O.L 4 LIS Instrument (D) Result Query H.Q.L Results Upload ([] can be repeated, C & M not Mandatory) With: 6/21 H: Header Record P: Patient Record O: Order Record Q: Query Record R: Result Record C: Comment Record M: Manufacturer Record L: Terminator Record 0932500_EN Description The instrument sends this query to the LIS to request the Worklist of a given sample. This is done automatically at loading time, if the option has been selected. The instrument uses this message to send back results to the LIS. It can be done automatically when the result is available if the option has been selected (see section 7.1). The results can also be sent to the LIS on request from the user from the This message is as used by the LIS archive menu or a response to to the send the workload of a4)given sample LIS result query. (See to the instrument. It can be done as a response to the Worklist query (see 1) or as a test or rerun request from the LIS. It can also be used to change test priority. This message is used by the LIS to get test results from the Instrument. STA Satellite Max ASTM Protocol 7 Instrument Setup 7.1 LIS Connection Setup LIS serial configuration: Term Definition Baud Rate Define the communication speed in Bauds (bit/s) Data Bits Define the number of data bits used to code each character Stop Bits Defines the number of stop bits Parity Define the type of parity check used Increment Specimen Sequence Define how the Instrument Specimen ID field will be generated by the STA Satellite Max . (See section 8.3 for a description) Control Transmission enabled If YES is checked, control results will be transmitted to the LIS Auto Transfer Enabled If YES is checked, the results will be automatically transmitted to the LIS. Host Query Enabled If YES is checked, the instrument will query automatically the LIS for the Worklist when loading a sample. Sample Re-query allowed If YES is checked, the instrument will query automatically the LIS for the Worklist each time the sample is loaded. Otherwise the query will be sent only when the sample is loaded the first time. Note: This field will be displayed only if the ‘Host Query’ option is enabled. Sample Re-query allowed The time The STA Satellite Max will wait for a response after a Sample Worklist Query. After this delay, the query is cancelled. ( see sections 8.6 and 9.1). Button to test communication setting with the LIS. 0932500_EN xxxx 7/21 20 STA Satellite Max ASTM Protocol 1 Test Setup : Term 8/21 Definition LIS Code Test ID sent to the LIS Internal code Internal code of the test sent to the LIS 0932500_EN STA Satellite Max ASTM Protocol 8 Detailed Message and Records Description The Section references are given for the CLSI document. The former ASTM document numbering is given between brackets. 8.1 Message Header Record CLSI LIS2-A2 (ASTM 1394) Value Field Description Format Record Type ID 1 ASCII character U D Comment Section 6.1 (7.1.1) ‘H’ 6.2 (7.1.2) Delimiter Definition ‘|’ ‘\’ ‘^’ ‘&’ 6.3 (7.1.3) ‘|’ 6.4 (7.1.4) ‘|’ Field Delimiter Repeat Field delimiter Component DelimiterDelimiter Escape 1 ASCII 1 ASCII characters 1 ASCII characters 1 ASCII characters characters Message control / ID / Access Not used Not used password 6.5 (7.1.5) Sender Name or ID ‘STA_Satellite_max’ ‘STA_Satellite_max’ The Serial Number is stored in the Instrument CPU board memory. The Version Number identifies the implementation of the protocol, not of the software. The Version Number cannot be changed 4 ASCII characters Name ‘ ‘^’ Serial Number 10 ASCII characters ‘1’ Version Number 1 ASCII characters 6.6 (7.1.6) ‘|’ Sender mailing address / Not used 6.7 (7.1.7) ‘|’ Reserved field / Not used 6.8 (7.1.8) ‘|’ Sender telephone number / Not used 6.9 (7.1.9) ‘|’ Sender characteristics / Not used Receiver ID N/A checked by the STA Satellite Max Comments or special instructions. / Text ‘^’ 6.10 (7.1.10) 6.11 (7.1.11) Ignored ‘|’ 1 ASCII character 6.12 (7.1.12) ‘P’ or ‘D’ 6.13 (7.1.13) ‘1’ 6.14 (7.1.14) Date-Time ‘P’ : Production (normal process) ‘D’ : Debug (Ignored) Processing ID Version Number 1 ASCII character The Receiver ID is accepted but is not Only the processing ID ‘P’ is accepted and transmitted by the STA Satellite Max. All other Processing IDs are ignored (D) and not transmitted (U). Identifies the version level of the specification. In download mode, this field is mandatory. 14 ASCII The message will not be recognized by the Date and Time of characters STA Satellite Max if this field is not present. Message ‘YYYYMMDDHHM MSS’ 0932500_EN xxxx 9/21 20 STA Satellite Max 8.2 ASTM Protocol Patient Information Record CLSI LIS2-A2 (ASTM 1394) Value Field Description Format U D Comment Section 7.1 (8.1.1) ‘P’ 7.2 (8.1.2) Record Type ID 1 ASCII character Sequence Number N ASCII characters Field size not limited / Up to 255 ASCII characters / Not used / Not used >1 7.3 (8.1.3) 7.4 (8.1.4) 7.5 (8.1.5) ‘|’ Patient ID ‘|’ Practice Assigned Patient ID Laboratory Assigned Patient ID Patient ID No 3 Not used Item1 ^ Item2 ^ Item3 ^ Item4 Both the Name and the First Name must be Patient Name 7.6 (8.1.6) Text ^ Text 7.8 (8.1.8) Date 7.9 (8.1.9) Ignored specified for the Patient Name field to be taken Last Name 255 ASCII characters max First Name 255 ASCII characters max Birth Date ASCII ‘YYYYMMDD’ Patient Sex 1 ASCII character ‘M’: ’F’: ’U’: 7.19 (8.1.19) 10/21 The Patient Sex field is accepted but ignored by the STA Satellite Max. It is never sent by the STA Satellite Max Both the Name and the First Name must be specified for the Patient Name field to be taken Text ^ Last Name 255 ASCII characters max Text First Name 255 ASCII characters max Patient’s known or suspected diagnosis N/A Ignored In Result Upload mode, If the specimen is a Control the Last name will be the Assay Internal Code as defined in the STA Satellite Max Application (See 7.2) and the first Name will be L_n where n is the control level Male Female Unknown Patient Name 7.14 (8.1.14) into account. 0932500_EN into account. In Result Upload mode, If the specimen is a Control the Last name will be the Assay Internal Code as defined in the STA Satellite Max Application (See 7.2) and the first Name will be L_n where n is the control level The Diagnosis field is accepted but ignored by STA Satellite Max. It is never sent by the STA Satellite Max STA Satellite Max ASTM Protocol CLSI LIS2-A2 (ASTM 1394) Value Field Description Format U D Comment Section 7.20 (8.1.20) Ignored Patient’s active Medications N/A The Medication field is accepted but ignored by the STA Satellite Max. It is never sent by the STA Satellite Max 7.25 (8.1.25) Ignored Admission Status N/A The Status field is accepted but ignored by the STA Satellite Max. It is never sent by the STA Satellite Max 7.26 (8.1.26) Text Location 255 ASCII characters max 7.34 (8.1.34) Ignored Hospital Institution N/A 8.3 The Institution field is accepted but ignored by the STA Satellite Max. It is never sent by the STA Satellite Max Test Order Record CLSI LIS2-A2 (ASTM 1394) Format U D Value Field Description Comment 8.4.1 (9.4.1) ‘O’ Record Type ID 1 ASCII character 8.4.2 (9.4.2) >1 Sequence Number N ASCII characters Field size not limited Section 8.4.3 (9.4.3) Patient ID Text ^ Barcode ID 255 ASCII characters max Ignored / N.T ^ Accession ID Ignored Text ^ Carrousel Barcode 255 ASCII characters max Carrousel Position 2 ASCII characters Instrument Specimen ID 1 to 9999 Text 8.4.4 (9.4.4) Accession ID is accepted but ignored by the Specimen ID Id (Text) STA Satellite Max. It is never transmitted by the STA Satellite Max. In Result Upload mode, If the specimen is a Control the Barcode Id will be : TIC CL (Test Internal Code – Control Level) Where TIC is the Assay Internal Code as defined in the STA Satellite Max. Application (See 7.2) and CL is L_n where n is the control level. 0932500_EN xxxx This field is generated by the STA Satellite Max as a number between 1 and 9999. The STA Satellite Max will affect either the same Instrument specimen ID to all the results of a given specimen or will generate a new specimen ID for each result depending on the flag ‘Increment Specimen Sequence’ described in section 7.1. The current value of the Instrument Specimen ID is stored in the Pc and the counting will continue in sequence at each software launch. 11/21 20 STA Satellite Max CLSI LIS2-A2 (ASTM 1394) Value ASTM Protocol Field Description U Format D Comment Section Universal Test ID 8.4.5 (9.4.5) Component 1-3 are NULL ^ ^ ^ Test Code (Text) ^ ‘#’,’F’ The value of the Test Code (component 4) is user defined in the Assay Definition. (See 7.2) Assay Code 5 ASCII characters max Result Type ^ 1 ASCII character ‘F’: Final Result ‘#’ : ‘1’ or ‘2’ for duplicates ‘48’ or ‘64’ ^ Plasma Type ‘48’ : Control ‘64’ : Specimen ‘90’, ‘91’ or ‘92’ ^ Component Name 2 ASCII characters ‘90’ : Control Level 1 ‘91’ : Control Level 2 ‘92’ : Control Level 3 Dilution (Text) ^ Dilution ‘X:Y’ NULL if no Dilution Ignored ^ Reagent Lot Number N/A Ignored Plasma Lot Number Priority 8.4.6 (9.4.6) 8.4.8 (9.4.8) ‘S’, ‘R’ ‘S’ : Stat ‘R’ : Routine Specimen Collection date and Time Action Code ‘A’, ‘N’, ‘C’ ‘A’ and ‘S’ are both interpreted as Stat N/A 1 ASCII character ‘A’ : Add Requests ‘N’ : New Requests ‘C’ : Cancel Requests Report Type 8.4.26 (9.4.26) The F flag (Final result) is used to notify that a result has been obtained either by averaging two duplicate results or by applying a mathematical formula defined for a calculated test. The different results that are used to compute the final results are flagged with ‘1’ and ‘2’ (duplicates). 1 ASCII character ‘S’, ‘A’ : Stat Ignored / N.T. STA Satellite Max Universal Test ID max length is 5 N/A ‘S’, ‘A’ 8.4.12 (9.4.12) X’,‘F’,‘Z’,’Q’ ‘O’,’F’,’Y’,’Z’,’Q’ 8.4 This field is NULL in Upload mode ( Result transmission from the STA Satellite Max to the LIS). Other codes are ignored by the STA Satellite Max 1 ASCII character ‘X’: Order Cancelled (U) ‘O’: Order for Analysis (D) ‘F’: Final Results ‘Y’: No order on record (D) ‘Z’: No record for this patient ‘Q’: Response to a Query Other codes are never sent by the STA Satellite Max Other codes are ignored by the STA Satellite Max Result Record The Result Record is used by the STA Satellite Max to transmit assay results associated with a given sample (Order) to the LIS. CLSI LIS2-A2 (ASTM 1394) Value Field Description Format U D Comment Section 9.1 (10.1.1) ‘R’ Record Type ID 1 ASCII character 9.2 (10.1.2) >1 Sequence Number N ASCII characters Field size not limited 12/21 0932500_EN STA Satellite Max CLSI LIS2-A2 (ASTM 1394) ASTM Protocol Value Field Description Format U D Comment Section Universal Test ID 9.3 (10.1.3) ^ ^ ^ Test Code (Text) ^ ‘#’,’F’ ^ ‘48’ or ‘64’ ^ ‘90’, ‘91’ or ‘92’ Assay Code 5 ASCII characters max Result Type 1 ASCII character ‘F’: Final Result ‘#’: ‘1’ or ‘2’ for duplicates Plasma Type Ignored ^ The value of the Test Code (component 4) is user defined in the Assay Definition. (See 7.2) STA Satellite Max Universal Test ID max length is 5 ‘48’: Control ‘64’: Specimen Component Name 2 ASCII characters ‘90’ : Control Level 1 ‘91’ : Control Level 2 ‘92’ : Control Level 3 Dilution ‘X:Y’ NULL if no Dilution ^ Dilution (Text) ^ Component 1-3 are NULL Reagent Lot Number N/A Plasma Lot Number 9.4 (10.1.4) Ignored N/A Value (Text) Data or 255 ASCII characters max Measurement Value When a Result is not available due to an error, this field contains the text : 'NO RESULT' (Multiple results are supported) 9.5 (10.1.5) Unit (Open Text) 9.6 (10.1.6) Units 255 ASCII characters max ‘|’ Reference ranges / Not used 9.7 (10.1.7) ‘|’ Result Abnormal Flags / Not used 9.8 (10.1.8) ‘|’ Nature of abnormality testing / Not used 9.9 (10.1.9) 'F’ Result Status 1 ASCII character, multiple status separated by commas Only ‘Final Result’ supported ‘F’: Final result 9.10 (10.1.10) ‘|’ / Not used Operator Identification 255 ASCII characters This field will contain the user name under which the STA Satellite Max session is open at the result is sent Not used Date of Change in Instrument Normative Values or Units 9.11 (10.1.11) UserName (Text) 9.12 (10.1.12) ‘|’ Date/Time test started / 9.13 (10.1.13) Date-Time Date/Time Test Completed ASCII ‘YYYYMMDDHHMMSS’ 0932500_EN xxxx 13/21 20 STA Satellite Max 8.5 ASTM Protocol Comment Record The Comment Records contains CLSI LIS2-A2 (ASTM 1394) Format U D Value Field Description Comment 10.1 (11.1.1) ‘C’ Record Type ID 1 ASCII character 10.2 (11.1.2) >1 Sequence Number N ASCII characters Field size not limited Section 10.4 (11.1.4) Comment Text (Text) Comment Code 255 ASCII characters max Comment Text 255 ASCII characters max In download mode, the Comment Text field is ignored by the STA Satellite Max ^ (Text) * In Upload mode, depending on the Comment Code, the Comment Text Component is either clear text describing the Comment Code or the internal error code that is displayed in the result detail in the GUI * 10.5 (11.1.5) ‘I’, ‘G’ ‘G’ Comment Type 1 ASCII character 1 ASCII character In download mode comments are only accepted for Order Records ‘I’: Flag ‘G’: Generic * [STX]4R|1|^^^2^F^64|2.67|g/l||||F||Manufacturer||20180215115247[CR][ETX]B5[CR] [STX]5C|1||-4001^OWREN-KOLLER buffer manally identified|I[CR][ETX]46[CR] [STX]6C|2||-4003^STA-FIB 5 manually identified|I[CR][ETX]04[CR] [STX]7C|3||-3004^Test Co 08 Result > is greater than verification high value|I[CR][ETX]FB[CR] [STX]0C|4||36^Test Co 08 controls are invalid|I[CR][ETX]EE[CR] Table of Errors and Flag Codes: Please refer to section 8.10 14/21 0932500_EN STA Satellite Max 8.6 ASTM Protocol Request Information Record The Query Information Record is used By the STA Satellite Max : to query the Worklist associated with a given sample ID (Barcode ID) from the LIS By the LIS to query results associated with a given Sample (Order) from the STA Satellite Max CLSI LIS2-A2 (ASTM 1394) Format U D Value Field Description Comment 11.1 (12.1.1) ‘Q’ Record Type ID 1 ASCII character 11.2 (12.1.2) >1 Sequence Number N ASCII characters Field size not limited Section 11.3 (12.1.3) Starting Range ID Number Ignored / N.T 'ALL' (text) can be used Hospital ID N/A Barcode ID 255 ASCII characters Ending Range ID Number N/A ^ (Text) 11.4 (12.1.4) Ignored / N.T Universal Test ID 11.5 (12.1.5) ^ ^ ^ This field is NULL in Upload mode Component 1-3 are NULL The value of the Test Code (component 4) is user defined in the Assay Definition. (See 7.2) 5 ASCII characters max Test Code (Text) ^ ‘#’,’F’ ^ STA Satellite Max Universal Test ID max length is 5 Assay Code Result Type 1 ASCII char ‘F’: Final Result ‘#’: ‘1’ or ‘2’ for duplicates ‘48’: Control ‘64’: Specimen ‘48’ or ‘64’ ^ ‘90’, ‘91’ or ‘92’ Plasma Type Component Name ^ 'ALL' (text) can be used 2 ASCII characters ‘90’ : Control Level 1 ‘91’ : Control Level 2 ‘92’ : Control Level 3 ‘X:Y’ NULL if no Dilution Dilution (Text) ^ Dilution N/A Ignored ^ Reagent Lot Number Ignored Plasma Lot Number N/A 11.6 (12.1.6) ‘R’ Ignored Nature of Request Time Limits 1 ASCII character 1 ASCII character Specifies that the Date/ Time specified in 11.7 (12.1.7) and 11.8 (12.1.8) are Result Test Date/Time 11.7 (12.1.7) Date-Time Beginning ASCII ‘YYYYMMDDHHMMSS’ Request Results date and Time 11.8 (12.1.8) Date-Time Ending Request ASCII ‘YYYYMMDDHHMMSS’ Results date and Time 0932500_EN xxxx 15/21 20 STA Satellite Max CLSI LIS2-A2 (ASTM 1394) Value ASTM Protocol Field Description Format U D Comment Section ‘N’, ‘O’, ‘D’, ‘A’ ‘N’, ‘F’ 11.13 (12.1.13) Request Information Status Code 1 ASCII character 1 ASCII character ‘N’: Requesting New or Edited result only ‘O’: Requesting Test Orders and Demographics only ‘D’: Requesting Demographics Only ‘F’: Final Results ‘A’: Abort/Cancel Last Request 8.7 Message Terminator Record The Terminator Record Terminates a message. It is mandatory. CLSI LIS2-A2 (ASTM 1394) Format U D Value Field Description Comment 12.1 (13.1.1) ‘L’ Record Type ID 1 ASCII character 12.2 (13.1.2) ‘1’ Sequence Number 1 ASCII characters 12.3 (13.1.3) ‘N’ Termination Code 1 ASCII characters Specifies a Normal Termination Section 16/21 0932500_EN STA Satellite Max 8.8 ASTM Protocol Manufacturer Information Record The Manufacturer Information record contains the lot numbers of the products that have been used to perform an assay. The Manufacturer Record is transmitted by the Satellite Max. It is always associated with a Result Record and follows immediately after the Result Record and after the associated Comments Records if any. Only one Manufacturer record can be sent with a given result. If a Manufacturer Record is received by the STA Satellite Max it will be ignored. CLSI LIS2-A2 (ASTM 1394) Value Field Description Format U D Comment Section 14.1 (15.1.1) ‘M’ Record Type ID 1 ASCII character 14.2 (15.1.2) >1 Sequence Number N ASCII characters Field size not limited 5 ASCII characters max The value of the Test Code (component 4) is user defined in the Assay Definition. 255 ASCII characters max Test Code (Text) Product name ^ Assay Code Diluent 20 ASCII characters max Lot Number Product name ^ Decontaminant Reagent 1 Reagent 2 Reagent 3 Start Reagent Lot Number 255 ASCII characters max 255 ASCII characters max 20 ASCII characters max Lot Number Product name ^ 255 ASCII characters max All fields, including unused fields should be transmitted. Unused fields should be left blank. 20 ASCII characters max Lot Number Product name ^ 20 ASCII characters max Lot Number Product name ^ 255 ASCII characters max 20 ASCII characters max Lot Number Product name ^ 20 ASCII characters max Lot Number Product name ^ 255 ASCII characters max Control 255 ASCII characters max 20 ASCII characters max 0932500_EN xxxx If the Manufacturer Record is associated with a control Result, the Control lot Number should be placed in this field, otherwise the field should be left blank 17/21 20 STA Satellite Max 8.9 ASTM Protocol Error and Flag Code Table Code Comment Type Result STA Satellite Max Common codes 36 Invalid Assay controls Alarm Result transmitted -691 Un-calibrated assay Alarm Result transmitted -2232 No Clot Error Alarm Result transmitted STA Satellite Max Specific Errors Codes -3001 Panic Low Result Flag Alarm Result transmitted -3002 Panic High Result Flag Alarm Result transmitted -3003 Low Result Flag Alarm Result transmitted -3004 High Result Flag Alarm Result transmitted -3005 Duplicate Error Error Mean value not transmitted*. Results 1 and 2 transmitted. -3006 Linearity Error Error Result not transmitted* -3007 Calculation error Error Result not transmitted* -3008 Calibration Range Error Result not transmitted* -3009 Parallelism Error Error Result not transmitted* -3010 Missing product Error Error Result not transmitted* -3011 Optical Measurement Error (Noise) Error Result not transmitted* -3012 No Result Found Error Error Result not transmitted* -3013 Positive Hook effect Error Result not transmitted* -3014 Optical Interferent in reaction Alarm Result transmitted -3015 No level detection Alarm Result transmitted -3016 Stirring Alarm Result transmitted -3017 Initial Tray Error Result not transmitted* -3018 Final Tray Error Result not transmitted* -3019 Jump Error Result not transmitted* -4001 Product / Buffer Identified Manually Alarm Result transmitted -4002 Product / Cleaner Identified Manually Alarm Result transmitted -4003 Product / Starter Identified Manually Alarm Result transmitted -4004 Product / Reagent 1 Identified Manually Alarm Result transmitted -4005 Product / Reagent 2 Identified Manually Alarm Result transmitted -4006 Product / Reagent 3 Identified Manually Alarm Result transmitted -4007 Sample identified manually Alarm Result transmitted 5002 Optical Reader Error Error Result not transmitted* 5003 Other Module Error** Error Result not transmitted* * When a Result is not available due to an error, this field contains the text: 'NO RESULT' ** Code 5003: Module problem or insufficient quantity of plasma (QNS), see the screen analyzer for more accuracy. 18/21 0932500_EN STA Satellite Max ASTM Protocol 9 Examples of Messages sent to the LIS In the following, the example frames are given in full, including the framing characters and checksum. For a complete specification of the Low level Communication Specification please refer to the LIS01A2 Document. 9.1 Queries 9.1.1 Worklist Query The STA Satellite Max sends this message to the LIS if the option ‘Host Query Enabled’ is activated and in the following cases: After a bar-coded sample is loaded. After an unidentified sample has been given an ID manually. Example: Query Work Load for the sample with Barcode ID = 100250 [Stx]1H|\^&|||STA_Satlellite_Max^08M10110 ^1|||||||P|1|20090701105221[CR][Etx]FF[CR] [Stx]2Q|1|^100250||ALL||||||||O[CR][Etx]44[CR] [Stx]3L|1|N[CR][Etx]00[CR] 9.1.2 Worklist Query Cancelled If No Worklist has been received for this sample after the time-out defined in the LIS setup, the STA Satellite Max sends a cancel query message: [Stx]1H|\^&|||STA_Satlellite_Max^08M10110 ^1|||||||P|1|20090701105234[CR][Etx]FF[CR] [Stx]2Q|1|^100250||ALL||||||||A[CR][Etx]33[CR] [Stx]3L|1|N[CR][Etx]00[CR] 9.2 Results Upload 9.2.1 Patient Result Upload No Patient Information Sample Barcode: 300105 In Carousel: 0902-0901 At Position: 3 Sequence Number: 205 Assay LIS Code: 10011 Result: 17.50 Unit: Second User Name: UserName Reagent Used: STA-TROMBIN 10 (Starter) Reagent Lot: 250076 [Stx]1H|\^&|||STA_Satlellite_Max^0007M10052^1|||||||P|1|20090504141209[CR][Etx]1E[CR] [Stx]2P|1[CR][Etx]3F[CR] [Stx]3O|1|300105^^0902-0901^3|205||R||||||||||||||||||||F[CR][Etx]46[CR] [Stx]4R|1|^^^10011^F^64|17.50|S||||F||UserName||20090504141208[CR][Etx]88[CR] [Stx]5M|1|10011||||||STA-TROMBIN 10^250076[CR][Etx]F5[CR] [Stx]6L|1|N[CR][Etx]09[CR] 0932500_EN xxxx 19/21 20 STA Satellite Max ASTM Protocol 9.2.2 Patient Result Upload with Alarms and Patient Information Patient Last Name: Smith Patient First Name: John Patient Birth Date: 24 January 1985 Physician Name: Steve Henderson Patient Location: 1258 Sample Barcode: 302157 In Carousel: 0902-0901 At Position: 6 Sequence Number: 210 Assay LIS Code: 10011 Result: 17.50 Unit: Second User Name: UserName Reagent Used: STA-TROMBIN 10 (Starter) Reagent Lot: 250076 [Stx]1H|\^&|||STA_Satlellite_Max^0007M10052^1|||||||P|1|20090504141209[CR][Etx]1E[CR] [[Stx]2P|1||||Smith^John||19850124||||||Steve Henderson||||||||||||1258[CR][Etx]0C[CR] [Stx]3C|1||-4007^Sample has been manually identified |I[CR][Etx]96[CR] [Stx]4O|1|302157^^0902-0901^6|210||R||||||||||||||||||||F[CR][Etx]4F[CR] [Stx]5R|1|^^^10011^F^64|13.20|S||||F||UserName||20090504141230[CR][Etx]7D [CR] [Stx]6C|1||36^Assay ATT10 s controls are invalid|I[CR][Etx]E5[CR] [Stx]7M|1|10011||||||STA-TROMBIN 10^250076[CR][Etx]F7[CR] [Stx]0L|1|N[CR][Etx]03[CR] 9.2.3 Patient Result Upload – Result in Duplicate No Patient Information Sample Barcode: 305521 In Carousel: 0902-0901 At Position: 7 Sequence Number: 212 Assay LIS Code: 10011 Result (Mean Value): 15.65 Unit: Second User Name: UserName Reagent Used: STA-TROMBIN 10 (Starter) Reagent Lot: 250076 Result 1: 15.90 s Result 2: 15.40 s [Stx]1H|\^&||| STA_Satlellite_Max^0007M10052^1|||||||P|1|20090506103359[CR][Etx]24[CR] [Stx]2P|1|[CR][Etx]BB[CR] [Stx]3O|1|305521^^0902-0901^7|212||R||||||||||||||||||||F[CR][Etx]4F[CR] [Stx]4R|1|^^^10011^F^64|15.65|S||||F||UserName||20090506103359[CR][Etx]93[CR] [Stx]5M|1|10011||||||STA-TROMBIN 10^250076[CR][Etx]F5[CR] [Stx]6R|2|^^^10011^1^64|15.90|S||||F||UserName||20090506103358[CR][Etx]7E[CR] [Stx]7R|3|^^^10011^2^64|15.40|S||||F||UserName||20090506103359[CR][Etx]7D[CR] [Stx]0L|1|N[CR][Etx]03[CR] 20/21 0932500_EN STA Satellite Max ASTM Protocol 9.2.4 Control Result Upload Assay Internal Code: TQ_S Control: Level 1 Sequence Number: 235 Assay LIS Code: 10011 Result: 13.50 Unit: Second User Name: UserName Reagent Used: STA-TROMBIN 10 Reagent Lot: 250076 Control Used: STA-COAG CONTROL N Control Lot: 251070 [Stx]1H|\^&|||STA_Satlellite_Max^0007M10052^1|||||||P|1|20090504145243[CR][Etx]20[CR] [Stx]2P|1||||TQ S^L_1[CR][Etx]81[CR] [Stx]3O|1|TQ S L_1|235[CR][Etx]E5[CR] [Stx]4R|1|^^^10011^F^48^90|13.50|S||||F||UserName||20090504145243[CR][Etx]50[CR] [Stx]5M|1|10011|||||| STA-TROMBIN 10^250076|VERIFY CONTROL 1^S111557[CR][Etx]DD[CR] [Stx]6L|1|N[CR][Etx]09[CR] 0932500_EN xxxx 21/21 20