INSTALACIONES ELÉCTRICAS CALCULO DE LA MAXIMA DEMANDA A. PRIMER PISO TD 01 A.1 VIVIENDA UNIFAMILIAR Watt Watts/ s/m2 m2 AREA CONSTRUIDA AREA LIBRE THERMA vol = 130 litros 93.87 52.81 Cons Consum umo o (Wa (Watt ttss ) 25 5 1500 2346.75 264.05 1500 C.I.1 4110.8 Watts CALCULO DEL CARGA INSTALADA TOTAL C.I.T=(AREA CONST. + AREA LIBRE + CARGA) C.I.T= 4110.8 wa watts CALCULO DE LA MAXIMA DEMANDA M.D=C.I.Txfd M.D= 2000 M.D= 610.8 M.Dtherma= 1500 M.D= 100% 35% 100% 3713.78 watts TOTAL 2000 213.78 1500 CALCULO DE LA INTENSIDAD DE CORRIENTE I= 16.88 amperios REDONDEANDO: 20 AMP. COMERCIAL CABLE A USAR: # 12 THW COMERCIAL B. SEGUNDO PISO TD 02 B.2. VIVIENDA UNIFAMILIAR Areas(m2) Watts/m2 Consumo (W (Watts ) 109.2 25 2730 35.56 5 177.8 0 1500 1500 AREA CONSTRUIDA AREA LIBRE THERMA vol = 130 litros C.I.1 4407.8 Watts CALCULO DEL CARGA INSTALADA TOTAL C.I.T=(AREA CONST. + AREA LIBRE + CARGA) C.I.T= 4407.8 wa watts CALCULO DE LA MAXIMA DEMANDA M.D=C.I.Txfd M.D= 2000 M.D= 907.8 M.Dtherma= 1500 M.D= 100% 35% 100% 3817.73 watts TOTAL 2000 317.73 1500 CALCULO DE LA INTENSIDAD DE CORRIENTE I= 17.35 amperios REDONDENADO: 20 AMP COMERCIAL CABLE A USAR: # 12 THW COMERCIAL “INSTALACIONES “INSTALACIONE S ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN” INSTALACIONES ELÉCTRICAS C. AZOTEA TD 03: C.1. VIVIENDA UNIFAMILIAR Areas(m2) Watts/m2 Consumo (Watts ) 33.17 25 829.25 39.59 5 197.95 0 1500 1500 2527.2 Watts AREA CONSTRUIDA AREA LIBRE THERMA vol = 130 litros C.I.1 CALCULO DEL CARGA INSTALADA TOTAL C.I.T=(AREA CONST. + AREA LIBRE + CARGA) C.I.T= 2527.2 watts CALCULO DE LA MAXIMA DEMANDA M.D= M.D= M.Dtherma= M.D=C.I.Txfd 1027.2 0 1500 M.D= TOTAL 100% 1027.2 35% 0 100% 1500 2527.2 watts CALCULO DE LA INTENSIDAD DE CORRIENTE I= D. 11.49 amperios REDONDEANDO: 16 AMP. COMERCIAL CABLE A USAR: # 12 THW COMERCIAL TOTAL TG-01: D.1. VIVIENDA UNIFAMILIAR 1° PISO TD 01: I= 16.88 amperios I= 17.35 amperios I= 11.49 amperios TOTAL TG 01 I= 45.72 amperios 2° PISO TD 02: AZOTEA TD 03:_ REDONDEANDO: 50 AMP. COMERCIAL CABLE A USAR: # 10 THW COMERCIAL “INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN” INSTALACIONES ELÉCTRICAS E. CALCULO DE CAIDA DE TENSION: E.1. VIVIENDA UNIFAMILIAR 1° FORMULA GENERAL DE CAIDA DE TENSION: I= 40A ∫= 0.0175 L= 1M S= 5,3mm2 (CALIBRE 10 THW) K= 1.0 Monofacico DATOS 40 0.0175 1 5.3 AV= 0.13 1 V CUMPLE CALCULO DEL CONDUCTOR SEGÚN EL "A" CALCULO DEL LA TUBERIA PVC - L EN PULGADAS “INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN” INSTALACIONES ELÉCTRICAS “INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN”