INSTALACIONES ELÉCTRICAS
CALCULO DE LA MAXIMA DEMANDA
A. PRIMER PISO TD 01
A.1 VIVIENDA UNIFAMILIAR
Watt
Watts/
s/m2
m2
AREA CONSTRUIDA
AREA LIBRE
THERMA vol = 130 litros
93.87
52.81
Cons
Consum
umo
o (Wa
(Watt
ttss )
25
5
1500
2346.75
264.05
1500
C.I.1
4110.8 Watts
CALCULO DEL CARGA INSTALADA TOTAL
C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
4110.8 wa
watts
CALCULO DE LA MAXIMA DEMANDA
M.D=C.I.Txfd
M.D=
2000
M.D=
610.8
M.Dtherma=
1500
M.D=
100%
35%
100%
3713.78 watts
TOTAL
2000
213.78
1500
CALCULO DE LA INTENSIDAD DE CORRIENTE
I=
16.88 amperios
REDONDEANDO: 20 AMP. COMERCIAL
CABLE A USAR: # 12 THW
COMERCIAL
B. SEGUNDO PISO TD 02
B.2. VIVIENDA UNIFAMILIAR
Areas(m2)
Watts/m2 Consumo (W
(Watts )
109.2
25
2730
35.56
5
177.8
0
1500
1500
AREA CONSTRUIDA
AREA LIBRE
THERMA vol = 130 litros
C.I.1
4407.8 Watts
CALCULO DEL CARGA INSTALADA TOTAL
C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
4407.8 wa
watts
CALCULO DE LA MAXIMA DEMANDA
M.D=C.I.Txfd
M.D=
2000
M.D=
907.8
M.Dtherma=
1500
M.D=
100%
35%
100%
3817.73 watts
TOTAL
2000
317.73
1500
CALCULO DE LA INTENSIDAD DE CORRIENTE
I=
17.35 amperios
REDONDENADO: 20 AMP COMERCIAL
CABLE A USAR: # 12 THW
COMERCIAL
“INSTALACIONES
“INSTALACIONE
S ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR
UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE
LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN”
INSTALACIONES ELÉCTRICAS
C.
AZOTEA TD 03:
C.1. VIVIENDA UNIFAMILIAR
Areas(m2)
Watts/m2 Consumo (Watts )
33.17
25
829.25
39.59
5
197.95
0
1500
1500
2527.2 Watts
AREA CONSTRUIDA
AREA LIBRE
THERMA vol = 130 litros
C.I.1
CALCULO DEL CARGA INSTALADA TOTAL
C.I.T=(AREA CONST. + AREA LIBRE + CARGA)
C.I.T=
2527.2 watts
CALCULO DE LA MAXIMA DEMANDA
M.D=
M.D=
M.Dtherma=
M.D=C.I.Txfd
1027.2
0
1500
M.D=
TOTAL
100%
1027.2
35%
0
100%
1500
2527.2 watts
CALCULO DE LA INTENSIDAD DE CORRIENTE
I=
D.
11.49 amperios
REDONDEANDO: 16 AMP.
COMERCIAL
CABLE A USAR: # 12 THW
COMERCIAL
TOTAL TG-01:
D.1. VIVIENDA UNIFAMILIAR
1° PISO TD 01:
I=
16.88 amperios
I=
17.35 amperios
I=
11.49 amperios
TOTAL TG 01 I=
45.72 amperios
2° PISO TD 02:
AZOTEA TD 03:_
REDONDEANDO: 50 AMP.
COMERCIAL
CABLE A USAR: # 10 THW
COMERCIAL
“INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE
LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN”
INSTALACIONES ELÉCTRICAS
E.
CALCULO DE CAIDA DE TENSION:
E.1. VIVIENDA UNIFAMILIAR
1° FORMULA GENERAL DE CAIDA DE TENSION:
I= 40A
∫= 0.0175
L= 1M
S= 5,3mm2 (CALIBRE 10 THW)
K= 1.0 Monofacico
DATOS
40
0.0175
1
5.3
AV=
0.13
1
V CUMPLE
CALCULO DEL CONDUCTOR SEGÚN EL "A"
CALCULO DEL LA TUBERIA PVC - L EN PULGADAS
“INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE
LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN”
INSTALACIONES ELÉCTRICAS
“INSTALACIONES ELECTRICAS DE UNA VIVIENDA UNIFAMILIAR UBICADA EN EL Psje. CANTUTA Nº 1327, CERRITO DE
LA LIBERTAD – PROVINCIA DE HUANCAYO – DEPARTAMENTO DE JUNIN”
Descargar