Subido por Luis Castaneda

A055B603

Anuncio
PTC
R
Creo
R
4
Parametric
2
3
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
1
2
3
ADD SHEET 6
ZONE (A1) ADD TABLE
ZONE (B1) UPDATE 'CIRCUIT BREAKER
ACCESSORIES' TABLE
RT MT M_TULADHAR 05NOV18
RT MT M_TULADHAR 05NOV18
RT MT M_TULADHAR 05NOV18
"H" FRAME SHOWN (15 - 150 amp)
NOTES:
1
POSITION "B"
POSITION "C"
1
NEUTRAL LUG (1) #14-2/0.
POSITION "A"
2
GROUND LUG (1) #14-1/0.
1
3
NEUTRAL LUG (1) #6-350 kcmil.
4
NEUTRAL LG (2) #2-600 kcmil OR (4) 1/0-250 kcmil.
FRAME
D
LUG
CB LUG TORQUE
D
(1) AL
(1) CU
#14 - 3/0 AWG
#14 - 3/0 AWG
0.65 inch
#14 - #10 50 lb-in (6.0 Nm)
#8 - 3/0 120 lb-in (14.0 Nm)
(1) AL
(1) CU
#4 - 4/0
#4 - 4/0
1.00 inch
225 lb-in (26.0 Nm)
AWG
AWG
AL250JD
J-FRAME
THERMAL-MAGNETIC
200-250 AMP
80% RATED
J-FRAME
LSI ELECTRONIC TRIP
ADJUSTABLE TRIP 70-250 AMP
100% RATED, COPPER CONDUCTORS ONLY
4X 554
WIRE STRIP LENGTH
DATE
AL175HD
J-FRAME
THERMAL-MAGNETIC
175 AMP
80% RATED
9X 633
WIRE RANGE
APVD
AL150HD
H-FRAME
THERMAL-MAGNETIC
15-150 AMP
80% RATED
1
LUG
CKD
(1) AL
(1) CU
3/0 - 350 kcmil
3/0 - 350 kcmil
1.00 inch
225 lb-in (26.0 Nm)
(1) CU
1/0 - 300 kcmil
1.00 inch
250 lb-in (28.0 Nm)
1.20 inch
442 lb-in (50 Nm)
CU250JD
2
9X 492
L-FRAME (400)
LSI ELECTRONIC TRIP
ADJUSTABLE TRIP 125-400 AMP
80% RATED
3X 258
L-FRAME (400)
LSI ELECTRONIC TRIP
ADJUSTABLE TRIP 125-400 AMP
100% RATED, COPPER CONDUCTORS ONLY
2
2
L-FRAME (600)
LSI ELECTRONIC TRIP
ADJUSTABLE TRIP 200-600 AMP
80% RATED
100% RATED, COPPER CONDUCTORS ONLY
193
C
337
390
P-FRAME MANUAL & AUTOMATIC
LSI ELECTRONIC TRIP
ADJUSTABLE TRIP 400, 600 & 800 AMP
80% AND 100% RATED
501
AL400L61K3
(1) AL #2 - 500 kcmil
(1) CU #2 - 600 kcmil
AL600LS52K3
(2) CU
2/0 - 500 kcmil
(1) 1.20 inch
(1) 2.40 inch
442 lb-in (50 Nm)
(2) AL
(2) CU
2/0 - 500 kcmil
2/0 - 500 kcmil
(1) 1.20 inch
(1) 2.40 inch
442 lb-in (50 Nm)
(3) AL
(3) CU
3/0 - 500 kcmil
3/0 - 500 kcmil
(3) 1.20 inch
442 lb-in (50 Nm)
AL600LS52K3
C
AL800LS52K3
628
961
1124
CIRCUIT BREAKER ACCESSORIES
1
AUXILIARY CONTACTS P/N A043X785
OPEN/CLOSED (OF)
TRIP INDICATION (SD)
FORM C CONTACTS
RATING: 6 AMPS AT 24 VAC, 48 VAC, 110 VAC
6 AMPS AT 24 VDC,
2.5 AMPS AT 48 VDC
0.6 AMPS AT 110 VDC
966
B
SHUNT TRIP (MX) P/N A043X760
12 VDC
COIL BURDEN < 5 WATTS
10 AMP IN-RUSH
B
2
H & J FRAME, MAXIMUM OF 4 CONTACTS PER
CIRCUIT BREAKER
569
476
3X 72
285
L FRAME, MAXIMUM OF 5 CONTACTS PER
CIRCUIT BREAKER
2X 35
P FRAME, MAXIMUM OF 5 CONTACTS PER
CIRCUIT BREAKER
ACCESSORY KIT P/N A060M822
FOR TOP ENTRY LOAD CABLE ENTRY
APPLICABLE FOR MODEL AND BREAKER
CONFIGURATION AS PER "TABLE 1"
3
9X 160
221
3X 105
TABLE 1
579
KIT PART NUMBER
MODELS AFFECTED
ENCLOSURES AFFECTED
C125 N6-C150 N6
A060M822
OPEN ONLY
C125 D6D- C200 D6D
KIT PART NUMBER
LIMITATION
NUMBER OF
CB'S
POS A
POS B
1
ANY RATING
-
2
ANY RATING
600A OR BELOW
-
3
ANY RATING
400A OR BELOW
250A OR BELOW
A060M822
2X 337
POS C
-
A
A
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
114
1/2
#1
X
DIM
A-A
.X
3
# 0.8
.XX # 0.38
ANG TOL
1.0
4
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
HOLE
79
SECTION
SCALE
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
1
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 1 of 7
PTC
R
Creo
R
4
Parametric
2
3
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
-
---
RT MT M_TULADHAR 05NOV18
CKD
APVD
DATE
"J" FRAME SHOWN (175 - 250 amp)
POSITION "A"
POSITION "C"
POSITION "B"
1
1
D
D
1
9X 636
2X 548
2X 554
9X 489
2
3X 258
C
C
2
193
2
337
390
501
628
961
1124
3X 1060
3X 966
3X 593
3X 476
B
3X 56
B
3X 285
3X 24
9X 153
2X 158
221
2X 165
580
3X 105
337
330
A
A
89
SECTION
SCALE
114
B-B
1/2
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
DIM
.X
HOLE
#1
X
# 0.8
.XX # 0.38
ANG TOL
1.0
4
3
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
2
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 2 of 7
PTC
R
Creo
R
4
Parametric
2
3
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
-
---
RT MT M_TULADHAR 05NOV18
CKD
APVD
DATE
"L" FRAME SHOWN (400 - 600 amp)
POSITION "B"
POSITION "A"
3
3
D
D
2X 724
4X 574
2X 384
2X 258
C
2
193
C
2
501
628
961
1124
1062
966
571
476
2X 31
B
B
4X 154
6X 179
221
578
2X 140
A
A
C-C
SECTION
SCALE
1/2
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
DIM
.X
HOLE
#1
X
# 0.8
.XX # 0.38
ANG TOL
1.0
4
3
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
3
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 3 of 7
PTC
R
Creo
R
4
Parametric
2
3
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
-
---
RT MT M_TULADHAR 05NOV18
CKD
APVD
DATE
"P" FRAME SHOWN (400-800 amp)
4
POSITION "B"
POSITION "A"
4
D
D
2X 736
4X 428
2X 409
2X 240
C
C
2
193
2
289
628
1009
1124
908
751
458
B
277
B
2X 31
536
221
12X 184
6X 158
2X 210
SECTION
SCALE
D-D
1/2
A
A
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
DIM
.X
HOLE
#1
X
# 0.8
.XX # 0.38
ANG TOL
1.0
4
3
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
4
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 4 of 7
PTC
R
Creo
R
4
Parametric
2
3
"H" FRAME SHOWN (15 - 150 amp)
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
-
---
RT MT M_TULADHAR 05NOV18
CKD
APVD
DATE
"L" FRAME SHOWN (400 - 600 amp)
E
E
D
D
140
140
96
96
554
627
627
CONDUIT
LANDING
AREA
574
CONDUIT
LANDING
AREA
481
384
195
195
C
C
E
E
REMOVE PUNCHOUT
IN FIELD
"P" FRAME SHOWN (400-800 amp)
SECTION
E-E
E
B
B
"J" FRAME SHOWN (175 - 250 amp)
E
140
96
627
CONDUIT
LANDING
AREA
140
428
409
96
554
627
240
CONDUIT
LANDING
AREA
548
195
467
A
A
E
195
E
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
DIM
.X
HOLE
#1
X
# 0.8
.XX # 0.38
ANG TOL
1.0
4
3
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
5
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 5 of 7
PTC
R
Creo
R
4
Parametric
2
3
1
REL NO
REV
NO
REVISION
DWN
ECO-181477
E
1
ADD SHEET 6
RT MT M_TULADHAR 05NOV18
CKD
APVD
DATE
A060M822 ACCESSORY KIT
ACCESSORY KIT (A060M822)
D
D
617
C
C
439
SCALE
3/10
CONDUIT VIEW SHOWN ARE FOR REFERENCE ONLY
B
B
A
A
UNLESS OTHERWISE SPECIFIED, ALL
DIMENSIONS ARE IN MILLIMETERS
DIM
.X
HOLE
#1
X
# 0.8
.XX # 0.38
ANG TOL
1.0
4
3
2
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
SCALE
1/4
0.00- 4.99 +0.15/-0.08
5.00- 9.99 +0.20/-0.10
10.00-17.49 +0.25/-0.13
17.50-24.99 +0.30/-0.13
SIM TO
.
DO NOT SCALE PRINT
THIS DOCUMENT (AND THE INFORMATION SHOWN THEREON) IS
CONFIDENTIALAND PROPRIETARY AND SHALL NOT BE DISCLOSED TO OTHERS
IN HARD COPY OR ELECTRONIC FORM, REPRODUCED BY ANY MEANS, OR
USED FOR ANY PURPOSE WITHOUT WRITTEN CONSENT OF CUMMINS INC.
DWN
CKD
APVD
DATE
A_JOHNSON
A_JOHNSON
P_LARSON
C UMMINS P OWER G ENERATION
R
02MAY16
FOR INTERPRETATION
OF DIMENSIONING AND
TOLERANCING, SEE
ASME Y14.5-2009
OUTLINE,CIRCUIT BREAKER
SITE CODE
FIRST USED ON
PGF
ARROW
DWG
SIZE
E
CAD SHEET
A055B603
6
OF
6
1
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 6 of 7
Part A055B603 E
Description
Legacy Name
External Regulations
Application Status
Release Phase Code
Security Classification
OUTLINE,CIRCUIT BREAKER
A055B603
UL,CSA
Production Only
Production
Internal use Only
Alternates
Part Specifications :A055B603 E
Name
Description
A030B356
SPECIFICATION,MATERIAL
CES10903
A055B604
DRAWING,ENGINEERING
A055B604
Regulatory Review and Approval is required prior to changing this item per
PGG 1-01-01-116. This item impacts compliance with these External Regulations:
UL,CSA
Legacy Name
Drawing Name: A055B604 Revision: E
Part Name: A055B603 Revision: E
ECO-181477
Sheet 7 of 7
Descargar