Remote Fill Spill Containment
Remote Fill and
Overfil­­l Prevention
Systems
Model No.
Spill Containment Description Stub Out Description
A1005-517SF
DW stainless steel, no drain, 5 gal
4” DW Dualoy® 3000/LCX
A1005-517SF3
DW stainless steel, no drain, 5 gal
3” DW Dualoy® 3000/LCX
A1005-517SF3SW
DW stainless steel, no drain, 5 gal
3” SW Red Thread®
A1005-616SF3SWV
DW SST primary/poly secondary, no drain, 15 gal
3” SW Red Thread®
Vapor Cap & Swivel Adapter
A1005-616SF3X
DW SST primary/poly secondary, no drain, 15 gal
3” DW Dualoy® 3000/LCX
Fill Cap & Swivel Adapter
A1005-616SF4
DW SST primary/poly secondary, no drain, 15 gal
4” DW Dualoy® 3000/LCX
Available options:
• Composite lid and stainless steel rim
• Lid and rim available powder coated to API color specifications
• Drain
• Electronic sensors
• 3” or 4” pipe
• 5 or 15 gallon capacity
Painted Lids - API Product Codes
Add to the end of the variant number:
-D
-R
-U
-V
-E
Yellow
White
Red
Orange
Bronze
ULSD
Regular
Premium
Vapor
E85
5 Gallon
15 Gallon
Contact Customer Service at 800-234-4394 for additional colors
Typical Complete System includes an A1005-517SF Double Wall Remote Fill Spill Containment, LCX,
5 gal, and an A1100-055SRF Remote Fill Overfill Prevention Assembly with Riser Assembly Kit
Remote Fill Overfill Prevention Assemblies
Description
Model No.
Valve Only, Remote Fill Export
A1100-011
Low Flow, (non-EPA CFR 40)
Remote Fill Export
A1100-054S
Remote Fill w/Cage BSPT
A1100-054SC
Remote Fill w/Cage NPT
A1100-054SCN
Remote Fill Kit, Buried E85
A1100-056SERF
Remote Fill Kit, Buried
A1100-056SRF
Remote Fill Kit, Sump E85
A1100-056SERFK
Remote Fill Kit, Sump
A1100-056SRFK
Upper Tube Lower Tube Max. Overall
Length C
Length B
Length A
Max. Burial
Depth
Nominal
Lbs.
Tank Dia.
N/A
N/A
N/A
N/A
N/A
5.0
47”
47”
47”
82”
82”
82”
82”
99”
99”
99”
94”
94”
94”
94”
161”
161”
161”
199”
199”
191”
191”
N/A
N/A
N/A
4.0’***
4.0’***
---
N/A
N/A
N/A
10.0’
10.0’
10.0’
10.0’
28.5
27.9
25.0
66.7
66.5
40.7
40.7
The A1100 Overfill Prevention Valve is not recommended for tanks under 6’ in diameter.
EMCO WHEATON RETAIL CORPORATION
Maximum burial depth assumes 95% shut-off and 6” clearance between top of drop tube and inside bottom of containment manhole lid.
2300 Industrial Park Drive • Wilson, North Carolina 27893
252-243-0150 • 252-243-4603 (fax) • www.emcoretail.com
*For additional applications and installation instructions, call Customer Service Department, 800-234-4394.
Emco Wheaton Retail Corporation
2300 Industrial Park Drive • Wilson, North Carolina 27893 • 252-243-0150 • 252-243-4759 (fax) • www.emcoretail.com
S-1014
07/21
© 2020 Emco Wheaton Retail Corporation
Remote Fill Piping Systems
A1100-056SRFK/A1100-056SERFK*
Overfill Prevention Valve
w/Remote Fill Kit Includes:
A1005-517SF (5 gal)
A1005-616SF (15 gal)
Glass-On
Spill Containment
A0716-044
Composite Manhole
A7900-004H
4” NPSM Male Pipe
Plug without O-ring
A1005-517SF
Remote Fill
Spill Containment
A0379-001
Remote Fill Cage
Adjustable NPSM
Dualoy® 4”
3000/LCX
• Creates true double wall containment from spill
bucket to the piping run
A0079-444
Tee 4”x4”x4”
• Assembly comes complete with stub, ready for
installation into the elbow and clamshell
3” or 4” double wall Dualoy® 3000/LCX OR
3” or 4” single wall Red Thread®
• 5 Gallon - Primary and secondary containment
A1100
OPV Assembly
Remote Fill
Only
Optional:
A0081-006JP
Remote Fill Piping
Test Assembly
vessels are rust-proof stainless steel
15 Gallon - Primary containment is rust-proof
stainless steel; secondary is polyethylene
*Compatible with E85 fuels
• Water-resistant cast iron lid with built-in handle
and exclusive triple wiper seal, meets H20 load
rating
Optional:
A0479-001
• Includes EZ-Gage for instant monitoring
Dip Stick Port
of interstitial space
• Never break concrete
Remote Fill/
Direct Fill
A1005-517SF3SW
Remote Fill
Spill Containment
Complete kits include
OPV & riser assembly
OPV
Assembly
Red Thread®
4” Secondary/3” Primary
R
WHEATON RETAIL
ULC Listed
MH21149
10’ Tank
A1100-056SRF
A1100-056SERF*
EMCO WHEATON RETAIL CORPORATION
2300 INDUSTRIAL PARK DRIVE
WILSON, N.C. 27893
IMPORTANT - Must use the supplied DO
riserNOT SCALE DRAWING-WORK TO DIMENSIONS SHOWN
DIMENSIONS ARE IN INCHES (DIMENSIONS IN BRACKETS ARE IN MILLIMETERS)
assemblies, A1100-055SRF or A1100-056SRF,
USED ON
DATE
DRAWN BY
UNLESS OTHERWISE SPECIFIED
as delivered, in order for the system to workDECIMALS
ANGLES
NPC
02/09/15
.X ± .030
.XX ± .015
.XXX ± .005 ± 1°
PROJECT NUMBER
DATE
CHECKED BY
properly and be vapor tight. Must
also
use TO INDUSTRY STANDARDS
CASTING
TOLERANCES
MACHINED SURFACES 125 RMS REMOVE ALL BURRS
for new installations or tank level retrofits
DATE
SCALE
WEIGHT
APPROVED BY
THE INFORMATION AND DESIGN DISCLOSED BY AND THE
N/A
that allow access to the top of the
tank.INThe
COPYRIGHT
THIS DRAWING ARE THE PROPERTY OF
EMCO WHEATON RETAIL CORP. AND CANNOT BE USED
MATERIAL
CASTING NUMBER
WRITTEN PERMISSION.
maximum burial depth with WITHOUT
the supplied
top nipple is 5’ for slip-on spill containment;
and 5 1/2’ for thread-on spill containment. For
deeper burial, call Emco Customer Service at
800-234-4394.
58
55
54
53
TALLER TANK
TANK BUNG
TANK BUNG
LONGER CONNECTIONS
REVISIONS
SYM
02/11/15
NPC
NPC
NPC
NPC
DATE
BY
05/22/15
03/04/15
03/04/15
493436EPA
Remote Fill
Cage
PART NAME
SIZE
DRAWING NUMBER.
A TS021015
PAGE
REV.
1
58
Vapor tight seal on ID
of 571209 Pipe Nipple
493436EPA
Remote
Fill Cage
A1100
Assembly
Riser
Assembly
Max burial
depth 5’ with
slip-on, and
5 1/2’ with
thread-on spill
containment
571210
4.19” ID
Tube
A0079-444
4” NPT
Tee
571209
Pipe Nipple,
4.5” length, ID
controlled for
vapor tight seal
*Compatible with E85 fuels