UPLC AMINO ACID ANALYSIS SOLUTION UPLC AMINO ACID Analysis Solution: T he right answ er for amino acid analysis nACQUITY UPLC chromatographic techniques for analyzing amino acids require scientists to make significant ® n System with the ACQUITY UPLC compromises depending on your analytical priorities. TUV Detector With the introduction of enabling technologies such as Waters® UltraPerformance LC,® AccQ•TagTM Ultra derivatization and separation chemistries including quality-control tested columns, reagents, and eluents n n ever before – without compromise – because Waters recognizes that you should not have to make trade-offs in order to achieve optimal analytical results. To meet the specific and rigorous demands of analyzing amino acids for protein pre-configured projects, characterization, cell culture monitoring, and nutritional analysis of foods and feeds, Waters has created a complete application Connections INSIGHT system: the UPLC® Amino Acid Analysis Intelligent Service Delivery Solution, part of the Waters Assured Platform (ISDP) Performance Solution (APS) family. ® Application-specific performance qualification n scientists can now achieve greater resolution, sensitivity, accuracy, and productivity than EmpowerTM 2 Software methods and report formats n Resolution, sensitivity, or throughput – you no longer have to choose just one. Traditional Full system- and applicationlevel support and documentation Assured Performanc e Solutions ENABLING YOU R SUCCESS WIT H P ROV EN INNOVAT IONS Waters Assured Performance Solutions designing instruments, chemistries, and methods for amino acids, highlighted by the development and (APS) form a family of systems that widespread success of our proven Pico•Tag® and AccQ•Tag chemistries. Today, Waters continues to lead bring together industry-leading the way in separations sciences by bringing together our most ground-breaking and popular technologies: technologies – instrumentation, the ACQUITY UPLC System and AccQ•Tag Ultra, the newest addition to the AccQ•Tag family of products. UPLC resolution: Analysis of a hydrolysate standard at 10 pmol/µL beyond, with Waters APS, you can 0.060 0.055 be assured that whenever a new 0.050 application challenge arises, Waters 0.030 0.025 0.020 The UPLC Amino Acid Analysis Solution provides high resolution to ensure method robustness with good quantitation. The short cycle time is obtained without compromising accurate results. Pro AU 0.035 Ile Leu Phe 0.040 Tyr Met Val Deriv Peak Cys 0.045 will have the technology and expertise to help you conquer it. Lys proteomics, chemical analysis, or Thr Whether you work in pharmaceuticals, scientists have come to expect from Waters. Ala application’s needs. lab-to-lab, around the world. And you can always rely on the expert applications support that Glu in choosing the best solution for your methodologies that assure you’ll get accurate results day-to-day, instrument-to-instrument, Asp these solutions remove the guesswork results. Just as important, our system solution includes rugged and reliable performance-qualified Arg Gly Designed by scientists for scientists, enhanced chromatographic resolution to ensure accurate and precise qualitative and quantitative Ser application-focused performance. acids. Derivatized amino acids are separated using the powerful ACQUITY UPLC System, which delivers His specifically optimized for exceptional, The UPLC Amino Acid Analysis Solution is holistically designed and optimized for analyzing amino NH3 tools, and services – that are AMQ chemistries, software, qualification The Waters UPLC Amino Acid Analysis (AAA) Solution is the product of more than 25 years’ experience 0.015 0.010 0.005 0.000 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 Minutes Intelligently designed The UPLC Amino Acid Analysis Solution leverages the best of Waters’ expertise in separation science, derivatization chemistries, and information management. Your lab will reap benefits from uncompromised chromatographic performance, accuracy, reliability, and reproducibility that cannot be found in any other system on the market today. ACQUIT Y UPLC System The ACQUITY UPLC System, engineered from the ground up with robust hardware to meet the demands of our unique sub-2 µm small-particle chemistries, is the highest performance LC system available. Its novel design accommodates pressure-tolerant particles and fluidic modules, minimized system volume, negligible carryover, and reduced cycle times. The system is rounded out with fast-response detectors, integrated system software and Connections INSIGHT ISDP instrument diagnostics to ensure continuous, consistent, and reliable operation in your lab. AccQ•Tag Ultra Chemistry Performance qualification AccQ•Tag Ultra Chemistries are a comprehensive and fully-tested set of Qualification services available for the UPLC Amino Acid Analysis reagents, columns and eluents optimized for use with the ACQUITY UPLC Solution meet the most stringent regulatory requirements. Installation, System. This chemistry is based on Waters’ widely-used and understood Operation, and Performance Qualification (IQ/OQ/PQ) protocols ensure AccQ•Tag derivatizaton method. High resolution separations are achieved that every element of the system is performing according to its intended using pre-qualified AccQ•Tag Ultra UPLC columns and mobile phases. use. An additional PQ, specific for amino acid analysis, is also available to Derivatized amino acids are quantified to sub-picomole levels with single verify performance and ensure accurate results. wavelength UV detection. Detection choices You can analyze all the amino acids at the maximum sensitivity using the ACQUITY UPLC TUV Detector. If you also use the system for other applications, you can choose an FLR or PDA detector. Derivatization with AccQ•Tag Ultra Chemistry The AccQ•Tag Ultra reagent, or ACQ, is an N-hydroxysuccinimideactivated hetercyclic carbamate. This reagent converts both primary and secondary amino acids in a high-throughtput batch process resulting in exceptionally stable derivatives. The resulting derivatives are stable at room temperature for up to one week. All components of AccQ•Tag Ultra chemistry, including the columns, derivitatization kits, and mobile phases, undergo strict QC testing. H R1 N N H O N N R2 NHR1R2 O N Amino Acid Derivatized Amino Acid O O O N t1/2 << 1s AQC Reagent + O HO N H20 t1/2 ~ 15s O N-Hydroxy Succinimide O HO NH2 N + + N O 6-Aminoquinoline N-Hydroxy Succinimide CO 2 P ERFORMANCE T HAT E XCEEDS E X P EC TAT IONS Powered by the ACQUITY UPLC System, our Assured Performance Solution for amino acid analysis delivers uncompromised resolution, sensitivity, and throughput in a robust, reliable method. Method robustness that minimizes variability The UPLC Amino Acid Analysis Solution provides you with control over the major factors that commonly cause variability in amino acid analysis. From optimized instrumentation and quality controlled chemistries to standardized Empower Software projects and qualification tools, you will rely on a method that is both rugged and reliable – a comprehensive and detailed approach that ensures successful analysis of every sample. Better resolution translates to accurate results Sub-2 µm particle UPLC technology delivers the greatest available column efficiency and resolution. With the system’s superior resolution of all amino acids, you will confidently achieve peak identification and quantitation, which in turn assures the accuracy of your results. For unequivocal peak identification, UPLC separation chemistries are fully compatible with mass spectrometry detection. Direct cell culture sample analysis Aliquots of cell culture media were taken directly from a bioreactor producing a biopharmaceutical protein. Samples were taken over a period of six days and no special sample preparation was required before analysis of the amino acids. The amino acid concentration trends can be plotted with growth as well as response to feeding. 0.65 0.60 Ala 0.55 0.50 Day 1 Day 3 Day 6 0.45 0.35 0.05 Thr 0.10 Asp 0.15 Gly 0.20 Arg 0.25 Glu Gln 0.30 Ser 0.00 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00 4.20 4.40 4.60 4.80 M inutes Cell Culture Media with Feeding Schedule 1000 900 800 C o n c (m g /L ) AU 0.40 700 G ln 600 Asp 500 Ala 400 L ys 300 200 100 0 0 2 4 Day 6 8 5.00 Qualification your lab can rely on AMQ T hroughput greater than what’s possible with traditional HPLC 0.060 Lys Because we know that getting the right answer every time is imperative Imagine achieving accurate amino acid analysis results in a fraction for your lab, Waters has invested the time, resources, and expertise in of the time required by conventional methods. The dramatically higher developing comprehensive qualification services to ensure that you get throughput possible with UPLC enables you to make more informed the accurate and reproducible results you expect. Our application-specific decisions faster, to perform more analyses per day, and to take on Performance Qualification is specific to amino acid analysis. A Waters- more projects per year. certified engineer will qualify your system using pre-configured amino 0.055 0.050 Asp Arg Gly Ser 0.025 Pro Glu 0.030 Ala Thr AU 0.035 Ile Leu Phe 0.040 Tyr Met Val Deriv Peak Cys 0.045 acid analysis methods and protocols, a QC-tested AccQ•Tag Ultra column, His NH3 0.020 0.015 reagents and eluents, as well as specific qualification documentation. 0.010 0.005 Flexible methodology: Analysis of a hydrolysate standard at 10 pmol/µL and a cell culture standard at 10 pmol/µL 0.000 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 Orn 0.055 0.055 Lys AMQ Lys AMQ 0.060 Deriv Peak Minutes 0.060 0.050 0.050 0.045 2.50 Ile Leu Phe Trp 7.00 Cys AABA HyLys1 HyLys2 Pro 6.50 Asp Glu GABA Tyr 2.00 Met Val NVa Ser Gln Arg Gly Tau Asn 0.015 0.015 NH3 HyPro 0.020 Ala Thr AU Pro 0.030 His Asp 0.035 0.025 His NH3 0.020 Arg Gly Ser 0.025 Glu 0.030 Ala Thr AU 0.035 0.040 Ile Leu Phe 0.040 Tyr Met Val Deriv Peak Cys 0.045 0.010 0.010 0.005 0.005 0.000 0.000 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 7.50 8.00 1.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 7.50 8.00 Minutes Lys Deriv Peak AMQ Orn Minutes 0.060 The trace on the left shows the analysis of a hydrolysate standard and the trace on the right shows a standard mixture of the larger number of amino acids found in cell culture media. The adaptation of the method requires only a change in dilution of the Eluent A Concentrate supplied as part of the total system solution. 0.055 0.050 7.00 Cys AABA 6.50 Asp Glu Pro Met Val NVa 2.50 Tyr 2.00 GABA Thr Ser Gln Arg Gly Tau Asn 0.015 NH3 HyPro 0.025 0.020 Ala 0.030 His AU 0.035 HyLys1 HyLys2 0.040 Ile Leu Phe Trp 0.045 0.010 0.005 0.000 1.50 3.00 3.50 4.00 4.50 Minutes 5.00 5.50 6.00 7.50 8.00 GOOD SCIENCE MEANS GOOD BUSINESS To achieve your goals, your laboratories must operate at their best. You continually balance short-term financial performance against long-term business goals. You need to meet ever-aggressive product availability and delivery schedules, which require shorter turnaround times from product development through production. Waters Assured Performance Solutions, including the UPLC Amino Acid Analysis Solution, simultaneously address laboratory productivity, efficiency, and analytical quality. Confirm quality You may need to determine the amino acid composition of a product and Your objective is to demonstrate process consistency. Concurrently, compare it with the composition deduced from the gene sequence for you have a production schedule to meet – and delays in any part of that product or its natural counterpart. Utilizing amino acid analysis to the process are expensive. Monitoring cell culture media for critical provide evidence of peptide or protein composition is an important tool nutrients allows you to optimize expression efficiencies and to make that supports effective discovery and lead development efforts. With timely product harvesting decisions. The UPLC Amino Acid Analysis the UPLC Amino Acid Analysis Solution, you can characterize proteins Solution provides the rugged, reliable performance you need to more comprehensively and efficiently, potentially accelerating your make the correct manufacturing decisions. You can depend on Waters biopharmaceutical development. instrumentation to enable you to achieve the product consistency you 0.095 Deriv Peak 0.100 AMQ Accelerate protein characterization 0.090 0.085 0.080 0.075 0.070 0.065 0.060 AU 0.055 Glu 0.050 0.045 need for validated protocols. And when your analyses are complete, Lys Leu Phe 0.040 0.035 Ile Val 0.025 Ala NH3 0.030 Asp you can utilize Waters NuGenesis ® Scientific Data Management System Tyr Pro His 0.005 Efficient and reliable foods and feed sample analysis: Soybean meal hydrolysate Cys 0.010 Met 0.015 Thr Ser 0.020 Arg Gly (SDMS) to automatically collect and archive results for easy future access. 0.000 -0.005 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 6.00 6.50 7.00 7.50 0.085 0.000 -0.005 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00 1.50 7.50 Minutes 2.50 Val Pro Ala MetSO2 3.00 3.50 4.00 4.50 5.00 5.50 7.00 7.50 Minutes Deriv Peak AMQ 0.100 2.00 His 0.005 -0.005 2.00 Cya 0.010 Tyr Ile Val 0.015 0.000 1.50 Ser 0.030 0.020 Met Cys His 0.005 0.035 Arg Gly Leu Phe Lys Pro 0.010 0.040 0.025 Tyr 0.015 Ala Ser 0.020 Thr 0.025 Arg Gly NH3 Asp 0.035 Asp 0.045 0.040 0.030 0.050 Leu 0.055 0.050 Phe 0.060 0.055 Ile 0.065 0.060 Lys 0.070 0.065 AU 0.075 0.070 Glu 0.080 0.075 0.045 Deriv Peak 0.090 Glu AU 0.080 0.095 Thr 0.085 AMQ 0.100 0.090 NH3 0.095 Deriv Peak 0.100 AMQ Minutes Two samples of hydrolyzed soybean meal were analyzed. The trace on the left shows the untreated sample while the trace on the right shows the results of performic acid oxidation. Note the appearance of cysteic acid and methionine sulfone in the oxidized sample. 0.095 0.090 0.085 0.080 0.075 Glu 0.070 0.065 0.050 Cya 0.005 His 0.015 0.010 Phe Ile Val MetSO2 0.020 Tyr 0.025 Pro Ser 0.030 Thr 0.035 Arg Gly 0.040 Ala Asp 0.045 Leu Lys 0.055 NH3 AU 0.060 0.000 -0.005 1.50 2.00 2.50 3.00 3.50 4.00 4.50 Minutes 5.00 5.50 6.00 6.50 7.00 7.50 Avoid costly reformulations Turnkey application support Amino acids are primary nutritional components in a wide variety of agri- What do protein hydrolysates, cell culture monitoring, and nutritional cultural feeds and food products. Are you concerned that your products are analysis of foods and feeds have in common? The need for trouble-free not meeting label claims for nutrient composition? With our UPLC Amino amino acid analysis. Our UPLC Amino Acid Analysis Solution comes with Acid Analysis Solution, you have access to Waters’ extensive experience in Empower Software projects, methods and report template to ensure that managing these complex analytical challenges. Our system solution will you are up and running quickly. You do not need to be an expert in amino enable you to get the right information, on a timely basis, so you can be acid analysis to get accurate, precise, and reproducible results for a broad assured that your products meet your manufacturing specifications. range of samples. Customized, easy-to-use data p rocessing and reporting The UPLC Amino Acid Analysis System Solution includes a CD with a set of processing methods and report formats that are useful for different applications. For example, the results can be reported with a sample chromatogram and the quantitative results can be reported in the most useful units for the application (e.g. mg/mL or molar ratios). Calibration reports also can be generated that summarize accuracy, precision, and linearity for the experimental measurements. Sales Offices: Austria 43 1 877 18 07 Australia 61 2 9933 1777 Belgium and Luxembourg 32 2 726 1000 Brazil 55 11 5094 3788 Canada 1 800 252 4752 China 86 10 8586 8899 Czech Republic 420 2 617 11384 Denmark 45 46 59 8080 Finland 358 9 5659 6288 France 33 1 30 48 72 00 Germany 49 6196 400 600 Hong Kong 852 2964 1800 Hungary 36 1 350 5086 India 91 80 2837 1900 Ireland 353 1 448 1500 Italy 39 02 265 0983 Japan 81 3 3471 7191 Korea 82 2 820 2700 Mexico 52 55 52 00 1860 The Netherlands 31 76 508 7200 Norway 47 6 384 6050 Poland 48 22 833 4400 Puerto Rico 1 787 747 8445 Russia/CIS 7 495 727 4490 / 290 9737 Singapore 65 6273 1221 Spain 34 93 600 9300 Sweden 46 8 555 115 00 Switzerland 41 62 889 2030 Taiwan 886 2 2543 1898 UK 44 208 238 6100 US 1 800 252 4752 Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 508 478 2000 F: 508 872 1990 www.waters.com Waters, ACQUITY, ACQUITY UPLC, Connections INSIGHT, NuGenesis, Pico•Tag, UltraPerformance LC, and UPLC are registered trademarks of Waters Corporation. AccQ•Tag, Empower, and The Science of What’s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. ©2006-2007 Waters Corporation. Printed in the U.S.A. January 2008 720001837EN LB-CP