OVF 5.7-21 Rev. 2 Dated: 09/27/2019 CERTIFICATE OF COMPLIANCE Certifies that the following products: MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) 8 PCS SERIAL NUMBERS: 2310038-001 THRU 2310038-008 TECNOVAL, LLC A 115 - (L-2) N/A 10/03/2023 Manufactured for buyer: Purchase Order #: Customer Part / Rev #: Customer PO Date: Were manufactured in accordance with contractual terms and the following standards and specifications: • OMNI PN# 3907-00C-996153B-G ________________________ Geo George Quality Manager Page 1 of 1 4520 Chandler Road, Muskogee, OK – 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-001 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2650 PSI 17 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 2:35:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:00:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-002 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2675 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:00:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:00:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-003 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2675 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:10:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:10:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-004 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2700 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:15:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:15:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-005 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2675 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:25:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:25:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-006 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2690 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:30:00 PM 11/08/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:30:00 AM 11/09/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/09/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-007 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 150 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2700 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:35:00 PM 11/09/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:35:00 AM 11/10/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/10/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105 OVF 5.7-49 Rev. 2 Dated:010/02/2018 ESD PRESSURE TEST DESCRIPTION: WORK 3907-00C-996153B-G ASSEMBLY # 2310038-008 ORDER # MODEL EX HYDRAULIC CONTROLLER WITH MANUAL PUMP & COVER HPILOT 500-1500 PSI (SET 1,400 PSI), LPILOT 50-450 PSI (SET 200 PSI), MOUNT: HORIZONTAL, HX-30, MOP: 3,000 PSI, SET PRESSURE: 2,700 PSI OPTIONS: EXTERNAL GAUGE, HI/LOW PILOT SYSTEM, NO LIMIT SWITCH ASSY SYSTEM HAZARDOUS AREA CERTIFICATION: CL1 DIV2 UL/CSA SOLENOID: NONE, RESERVOIR: 0.5 GAL, PUMP: MANUAL 0.55 CUIN DISP, FILL KIT # 3907-0000-00A (INCLUDED) WORK INSTRUCTION# OWI-A400-5.7 UNIT DATA RATED WORKING PRESSURE 3,000 PSI MANUAL YES PILOT 1 N/A PSI PILOT 2 N/A PSI N/A SOLENOID PILOT 3 N/A PSI PILOT 4 N/A PSI FILTERED HI-TEK HVI/AW 032 HYDRAULIC OIL TESTING FLUID UNIT SETUP ACCUMULATOR CHARGE PRESSURE 1,800 PSI KICK DOWN SETTING N/A PSI HIGH PRESSURE RELIEF SETTING N/A PSI REGULATOR SETTING 160 PSI PRESSURE TEST TEST PRESSURE HOLD START HOLD PRESSURE 2700 PSI 2700 PSI 16 HOURS PRESSURE HOLD END TEST 1 TEST 2 PASS / FAIL PASS / FAIL MANUAL PASS PASS SOLENOID N/A N/A PILOT N/A N/A TEST TYPE TECHNICIAN SIGNATURE: J. Settlemyre TIME TEST RESULTS 3:30:00 PM 11/09/2023 NO VISIBLE SIGNS OF LEAKAGE OR OTHER RELEVANT INDICATIONS UNDER THE TEST PRESSURE DURING EACH HOLDING PERIOD 7:30:00 AM 11/10/2023 FUNCTIONAL TEST PRESSURE THE UNIT UP TO THE RATED WORKING PRESSURE FOR EACH TEST. ALLOW PRESSURE TO STABILIZE BEFORE EACH TEST. DATE: 11/10/2023 4520 CHANDLER ROAD, MUSKOGEE, OK - 74403 Tel: 918-687-6100 Fax: 918-687-6105