Subido por rrivera_abalones

OkolodkovHuerta-Quintanilla 2012

Anuncio
See discussions, stats, and author profiles for this publication at: https://www.researchgate.net/publication/234129203
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine
Dinoflagellates
Article in Journal of Advanced Microscopy Research · December 2012
DOI: 10.1166/jamr.2012.1111
CITATIONS
READS
6
364
2 authors:
Yuri Okolodkov
Dora A. Huerta-Quintanilla
Universidad Veracruzana
Center for Research and Advanced Studies of the National Polytechnic Institute
181 PUBLICATIONS 2,645 CITATIONS
7 PUBLICATIONS 19 CITATIONS
SEE PROFILE
All content following this page was uploaded by Yuri Okolodkov on 30 May 2014.
The user has requested enhancement of the downloaded file.
SEE PROFILE
RESEARCH ARTICLE
Copyright © 2012 American Scientific Publishers
All rights reserved
Printed in the United States of America
Journal of
Advanced Microscopy Research
Vol. 7, 170–175, 2012
A Low Voltage Scanning Electron Microscopy
Study of the Theca of Marine Dinoflagellates
Yuri B. Okolodkov1 ∗ and Dora A. Huerta-Quintanilla2
1
Laboratorio de Botánica Marina y Planctología, Instituto de Ciencias Marinas y Pesquerías,
Universidad Veracruzana, Calle Hidalgo 617, Col. Río Jamapa, Boca del Río, 94290, Veracruz, México
2
Laboratorio Nacional para el Estudio de Nano y Biomateriales, Departamento de Física Aplicada,
Centro de Investigación y Estudios Avanzados–Instituto Politécnico Nacional, Unidad Mérida,
Carretera Antigua a Progreso Km 6, 97310, Mérida, Yucatán, México
A low voltage scanning electron microscopy regime is proposed for routine examination of the
non-metalized thecae of marine dinoflagellates,
a JEOL
Delivered byusing
Ingenta
to:JSM-7600F Field Emission scanning
electron microscope with a Schottky field-emission electron gun. The selected options were as
Vladimir Basiuk
follows: voltage 1–1.5 kV (sometimes up to 2 kV), working distance 15–20 mm, gentle beam,
IP
: 132.248.29.219
secondary electron detector, probe current 1–2 × 10−10 A, and specimen tilt 0 to 20 . Although the
Fri,
11
2013
15:45:43
micrographs taken at 5 kV were of higher Jan
quality,
satisfactory
resolution, contrast and magnification
in the micrographs taken at 1.0–1.2 kV were obtained. Minute details of the dinoflagellate theca such
as the apical pore complex, the sulcal area, the hypothecal pore, sutures and thecal ornamentation,
that are considered among the most important diagnostic features, were observed at up to 11,000×.
This indicates that images of thecate dinoflagellates can be obtained much less expensively and
faster when necessary, due to a more rapid procedure that includes only washing and dehydration
and does not include sputter coating with a metal. A long working distance helps the observations
by increasing the depth of focus.
Keywords: Dinoflagellates, Identification, Low Voltage Scanning Electron Microscopy,
Morphology, SEM, Taxonomy, Theca.
1. INTRODUCTION
Scanning electron microscopy (SEM) is widely used in
studies on the morphology of dinoflagellates, a group of
mainly marine planktonic unicellular organisms that are
known as causative agents of the so-called red tides or
harmful algal blooms and bioluminescence in the sea. The
taxonomy and systematics of dinoflagellates is based on
the morphological characteristics of the thecal or amphiesmal plates, which are the visible part of the theca1 or
amphiesma.2 3 Dinoflagellates are conventionally divided
into thecate and athecate (unarmored or naked) forms,
and the thecate ones have a theca visible by means of
light microscopy (LM). The plates consist of cellulose, and
they are located inside alveoli (sort of enclosed cisterns)
under the external plasmatic membrane. The cell cover
of dinoflagellates may contain dinosporin, a complex aromatic polymer similar to that in terrestrial plants but chemically different from it.4 More recent data indicate that
∗
Author to whom correspondence should be addressed.
170
J. Adv. Microsc. Res. 2012, Vol. 7, No. 3
dinoflagellate cyst walls are composed of a suite of chemically different biopolymers that can be species specific.5
The thecal plates are closely attached to each other and
form a continuous surface. The contact zones are called
sutures, and are also known as intercalary bands or growth
zones, due to the additional deposit of cellulose while the
cell volume increases. In some species growth occurs only
along one margin of the thecal plate; in others it occurs
along the whole perimeter. The theca of dinoflagellates
is characterized by tiny pores, under which trichocysts
(offense or defense organelles) that have a hairlike filament capable of being ejected are situated in most genera
and species. For a number of reasons, the LM remains
the main tool for identification of dinoflagellate species.
Balech6 stressed that there is no morphological detail of
the dinoflagellate theca shown by SEM that had not been
detected by those who used LM; however, he believed that
some new details of the apical pore complex (APC), sulcal
or cingular plates could be revealed by SEM. In addition
to these parts of the theca, one should add the theca ornamentation and the size and shape of the trichocyst pores.
2156-7573/2012/7/170/006
doi:10.1166/jamr.2012.1111
Okolodkov and Huerta-Quintanilla
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine Dinoflagellates
(5) coating the cells with a metal (usually with gold,
gold-palladium, palladium, sometimes with aluminum or
copper);
and (5) viewing with SEM in a vacuum or directly on
a stub in the case of environmental scanning electron
microscopes.7–12 Protocols may vary, especially when fragile unarmored species are under study, and may include
post-fixation with osmium tetroxide. Since the early 1980s,
hexamethyldisilazane (HMDS), an organosilicon compound, has been used in biological, medical and biomedical sciences as a method of chemical drying of dehydrated
cells.13–20
Delivered by Ingenta to:
Vladimir Basiuk
IP : 132.248.29.219
Fri, 11 Jan 2013 15:45:43
Fig. 1. Scanning electron micrographs taken of non-metalized specimens at 1.0–1.2 kV, lower secondary electron detector (LEI), with gentle beam
(GB). (a) Prorocentrum rotundatum J. Schill., right valve view; 1.0 kV, 2300×, working distance (WD) = 19 mm. (b) Dinophysis caudata Saville-Kent
var. pedunculata (Schmidt) Schröder, right side view; 1.2 kV, 1300×, WD = 21 mm. (c) Gonyaulax polygramma F. Stein, ventral-apical view; 1.0 kV,
1800×, WD = 18 mm. (d) Ceratocorys horrida F. Stein, antapical view; 1.2 kV, 1000×, WD = 20 mm. (e), (f) Diplopsalopsis bomba (F. Stein) Dodge:
(e)—apical view of the cell (epitheca), 1.0 kV, 2000×, WD = 19 mm; (f)—the apical pore complex (APC) bordered by three apical plates (1 –3 ),
1.0 kV, 9000×, WD = 21 mm. Scale bars: 10 m in (a)–(e), 1 m in (f).
J. Adv. Microsc. Res. 7, 170–175, 2012
171
RESEARCH ARTICLE
Protocols for SEM observations usually include
(1) washing the cells from fixative agents (paraformaldehyde, glutaraldehyde, Lugol’s solution or ethanol) and dissolved marine salts in distilled, deionized or nanopure
water or cacodylate or phosphate buffer;
(2) dehydration of specimens in a graded ethanol or acetone series;
(3) replacement of 100% ethanol or acetone with liquid
carbon dioxide by critical-point drying or sublimation drying in order to prevent cell shape distortion, or sometimes
just air-drying;
(4) mounting them on aluminum or copper stubs;
RESEARCH ARTICLE
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine Dinoflagellates
During the 1980s, low-voltage SEM (1 to 4 kV) became
routine in the semiconductor industry and then in both
zoology and botany.21–23 In comparison to the high-voltage
regime, more detailed information on the surface morphology and sometimes on the surface chemistry can be
obtained from low-voltage images.24
The aim of this paper is to show that it is possible
to study non-metalized (uncoated) and non-critical-pointdried biological samples in a high-resolution field emission
SEM microscope at low accelerating voltages, using the
r-filter and Gentle Beam facilities recently introduced in
these types of microscopes.
Okolodkov and Huerta-Quintanilla
2. MATERIALS AND METHODS
For our study, two phytoplankton samples collected on
13 March 2007 were selected out of about a hundred
samples taken in the National Park Sistema Arrecifal
Veracruzana, the southwestern Gulf of Mexico because of
(1) the almost total absence of detritus and diatoms that
are frequently much more abundant in the coastal zone and
therefore impede SEM observation and (2) the relatively
high morphological and species diversity of dinoflagellates
observed with an Olympus CKX41 inverted microscope
in a 1-ml Sedgwick-Rafter counting chamber. The samples were rinsed in distilled water four times in Eppendorf
Delivered by Ingenta to:
Vladimir Basiuk
IP : 132.248.29.219
Fri, 11 Jan 2013 15:45:43
Fig. 2. Scanning electron micrographs taken of non-metalized specimens at 1.0–1.2 kV, LEI, with GB. (a) Blepharocysta splendor-maris (Ehrenb.)
Ehrenb., ventral view; 1.0 kV, 1900×, WD = 19 mm. (b) Protoperidinium claudicans (Paulsen) Balech, ventral view; 1.2 kV, 1400×, WD = 21 mm.
(c) Protoperidinium oviforme (P. A. Dang.) Balech, ventral view; 1.0 kV, 1700×, WD = 19 mm. (d), (e) Protoperidinium concinnum Faust: (d)—ventral
view of the cell, 1.0 kV, 950×, WD = 19 mm; (e)—the apex without the APC, 1.0 kV, 10,000×, WD = 19 mm. (f) Protoperidinium venustum (Matzen.)
Balech, ventral view, 1.0 kV, 1200×, WD = 19 mm. Scale bars: 10 m in (a)–(d) and (f), 1 m in (e).
172
J. Adv. Microsc. Res. 7, 170–175, 2012
Okolodkov and Huerta-Quintanilla
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine Dinoflagellates
study (Figs. 1–3). For comparison, we took micrographs of
the same species (of the same non-metalized cell) at different voltages with and without the gentle beam and also
of another cell metalized with a 20–25 nm layer of goldpalladium (Fig. 4). The images obtained were not edited
in any way.
We used a JSM-7600F Field Emission SEM with a
Schottky field-emission electron gun, which easily gives
a stable and high probe current, as compared with traditional cold field-emission electron guns.25 The Gentle
Beam method slows down the electron beam just in front
of the specimen, reducing the electron beam energy to
Delivered by Ingenta to:
Vladimir Basiuk
IP : 132.248.29.219
Fri, 11 Jan 2013 15:45:43
Fig. 3. Scanning electron micrographs taken of non-metalized specimens at 1.0–1.2 kV. (a), (b) Protoperidinium divergens (Ehrenb.) Balech: (a)—
apical view of the cell (epitheca), 1.2 kV, 1200×, WD = 21 mm; (b)—the apical pore complex, 1.2 kV, 11,000×, WD = 21 mm. (c), (d) Protoperidinium
pellucidum Bergh: (c)—ventral view of the cell, 1.0 kV, 2000×, WD = 21 mm; (d)—a fragment of the theca showing the first postcingular plate (1 )
with the hypothecal pore (arrow head), and the anterior part of the sulcus: the anterior sulcal (S.a.) and right sulcal (S.d.) plates, and the transitional
plate (t). (e), (f) Protoperidinium divergens (Ehrenb.) Balech: (e)—ventral view of the cell, 1.0 kV, 1500×, WD = 19 mm; (f)—sulcal area, 1.0 kV,
3300×, WD = 19 mm. Scale bars: 10 m in (a)–(c) and (e), 1 m in Figures 2(e) and (f).
J. Adv. Microsc. Res. 7, 170–175, 2012
173
RESEARCH ARTICLE
1.5-ml vials (water was decanted every 1.5–2 hours). Then
they were dehydrated in a grade ethanol series (30, 50,
70, 90% and twice in 100%) and stirred before depositing 3 to 4 drops of the cell suspension on 0.5’ diameter aluminium stubs with a plastic 1-mm pipette and
air drying. After 20–30 min. the stubs were put into a
JEOL JSM-7600F STEM at the Center for Research and
Advanced Studies of the National Polytechnic Institute in
Merida, Yucatan, Mexico. To take microphotographs in
the low-voltage regime of a quality satisfactory for distinguishing particular morphological features allowing us
to identify species correctly was the main purpose of this
RESEARCH ARTICLE
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine Dinoflagellates
diminish specimen damage and charging, while keeping
the electron probe diameter small to ensure high resolution. This mode provides high-resolution images whose
quality is as high as those of higher accelerating voltages,
even though the electron energies close to the sample are
as low as 100 V to 3 kV. This way, the electron beam
hits the sample without damaging the information from the
specimen surface.26
After experimenting with HMDS and its application to
marine dinoflagellates and their observation with the same
SEM over the course of three months using 5 kV, we
decided to change to a 1 kV regime. The selected options
were as follows: voltage 1 kV (sometimes 1.2 kV), working distance about 20 mm (although sometimes we also
Okolodkov and Huerta-Quintanilla
reduced it to 15 mm), gentle beam (GB), secondary electron detector (LEI, or lower secondary electron image),
probe current 1–2 × 10−10 A, specimen tilt 0 to 20 .
3. RESULTS AND DISCUSSION
The micrograph taken at 5 kV (Fig. 4(f)) clearly demonstrated a higher quality, especially in resolution. However,
satisfactory resolution, contrast and magnification in the
micrographs taken at 1.0–1.2 kV must be noted (Figs. 1–3,
4(a)–(e)). This implies a wide possibility for obtaining
images of thecate dinoflagellates much less expensively
and faster when it is necessary, due to a more rapid procedure that includes only washing and dehydration and does
Delivered by Ingenta to:
Vladimir Basiuk
IP : 132.248.29.219
Fri, 11 Jan 2013 15:45:43
Fig. 4. Scanning electron micrographs of Protoperidinium concinnum taken of non-metalized (a)–(e) and a metalized specimen (f) at different voltages,
with gentle beam (GB) or without it (SEM), WD = 15 mm, magnification 1000×: (a)—1.0 kV, LEI, GB. (b)—1.5 kV, LEI, GB. (c)—2.0 kV, LEI,
GB. (d)—2.0 kV, LEI, SEM. (e)—5.0 kV, LEI, SEM. (f)—5.0 kV, LEI, SEM. Scale bar: 10 m.
174
J. Adv. Microsc. Res. 7, 170–175, 2012
Okolodkov and Huerta-Quintanilla
A Low Voltage Scanning Electron Microscopy Study of the Theca of Marine Dinoflagellates
4. CONCLUSIONS
The Gentle Beam method in the low-voltage regime
(< 5 kV) provides high-resolution images whose quality
is as high as those of higher accelerating voltages. The
described method applied to uncoated specimens can be
a cheaper and more rapid option for routine studies of
thecate dinoflagellates. A voltage of 1.2 kV or higher is
recommended during observations with the JEOL JSM7600F. A comparatively longer working distance (15 to
20 mm) and LEI help the specimens to avoid charging.
Acknowledgments: This study was partially supported by FOMIX-YUC No. 108160 (2008) and CONACYT LAB-2009-01 No. 123913 (2009) projects led
by Patricia Quintana-Owen (CINVESTAV-IPN, Mérida,
Mexico). We also appreciate the financial support of the
Universidad Veracruzana and the Departamento de Recursos del Mar (CINVESTAV-IPN) given to YBO to perform a sabbatical year in CINVESTAV-IPN in Merida
Nova Hedwigia 112, 415 (1996).
12. E. W. Truby, Microsc. Res. Tech. 36, 337 (1997).
13. J. L. Nation, Stain Technol. 58, 6 (1983).
14. S. Heegaard, O. A. Jensen, and J. U. Prause, Ophtalmic Res. 18, 4
(1986).
15. D. F. Bray, J. Bagu, and P. Koegler, Microsc. Res. Tech. 26, 6 (1993).
16. F. Braet, R. De Zanger, and E. Wisse, J. Microsc. 186, 84 (1997).
17. P. Oshel, Microscopy Today 97, 4 (1997).
18. R. Hochberg and M. K. Litvaitis, Biotech. Histochem. 75, 41 (2000).
19. S. Mitchell and W. Miller, J. Penn. Acad. Sci. 120, 3 (2008).
20. N. H. Hazrim-Chong and M. Manefield, J. Microbiol. Methods 90, 2
(2012).
21. D. C. Joy, Inst. Phys. Conf. Ser. 90, Chapter 7, EMAG 87,
Manchester, UK (1987), pp. 175–180, September 1987.
22. E. D. Boyes, Final Report, European Research Office of the U.S.
Army, London, England (1988), pp. 1–70, Contract No. DAJA
37-82-C-0271.
23. S. L. Erlandsen, P. T. Macechko, and C. Frethem, Scanning Microsc.
13, 43 (1999).
24. D. C. Joy and C. S. Joy, Micron 27, 3 (1996).
25. J. Pawley, Scanning 19, 324 (1997).
26. S. M. Stevens, K. Jansson, C. Xiao, S. Asahina, M. Klingstedt,
D. Grüner, Y. Sakamoto, K. Miyasaka, P. Cubillas, R. Brent, L. Han,
S. Che, R. Ryoo, D. Zhao, M. Anderson, F. Schüth, and O. Terasaki,
JEOL News 44, 17 (2009).
27. H. Kazumori, JEOL News 37E, 44 (2002).
Received: 24 September 2012. Accepted: 24 October 2012.
J. Adv. Microsc. Res. 7, 170–175, 2012
View publication stats
175
RESEARCH ARTICLE
and the hospitality of the host scientist Jorge A. Herreranot include sputter coating with a metal. On the whole,
Silveira and Fany del C. Merino-Virgilio in the Labothe general views of the cells looked rather good, as did
ratory of Marine Plankton. María C. Ramírez-Jáuregui
the close-ups of the APC/apex, the sulcal area or parts
from ICMyL-UNAM, Mexico City, kindly helped us with
of the theca at up to 11,000× (Figs. 1(f), 2(e), 3(b)).
literature, and Marcia M. Gowing from Seattle improved
Nevertheless, we noted a pronounced difference between
the writing style.
1.0 kV and 1.2 kV shown by the more distinct trichocyst
pores, so 1.2 kV or higher voltage is recommended during
observations with the JEOL JSM-7600F (Figs. 1(b), (d),
References and Notes
2(b), 3(a), (b), 4(b)).
1. K. A. Steidinger and E. R. Cox, Free-Living Dinoflagellates, edited
The effect of the r-filter secondary-electron detection
by E. R. Cox, Phytoflagellates, Elsevier/North Holland, New York
system is to remove very low energy secondary-electrons.
(1980), pp. 407–432.
These electrons are the most affected by the charging of
2. A. R. Loeblich, III, Proceedings of the North American Paleontological Convention, Part G, Chicago, USA (1970), September 1969.
the sample, and therefore removing them implies, in a way,
3. L. C. Morrill and A. R. Loeblich, III, Intern. Rev. Cytol. 82, 151
ignoring the charging of the samples due to the fact that
(1983).
they are non-conducting.27
4. J. P. Kokinos, T. I. Eglinton, M. Goni, J. J. Boon, P. A. Martoglio,
It should be noted that in the approach proposed here
and D. A. Anderson, Org. Geochem. 28, 265 (1998).
5. K. Bogus, G. Versteegh, I. Harding, U. Holzwarth, and K. Zonneveld,
we used a long working distance (15–20 mm). These long
Proceedings of the 44th Annual Meeting 2011, American Associdistances help the observation process by increasing the
ation of Stratigraphic Palynologists, Southampton, UK, September
depth of focus. The disadvantages usually related to long
(2011). to:
Delivered by Ingenta
working distances (increased probe size—increased aber6. E. Balech, Neotrópica 21, 20 (1975).
Vladimir Basiuk
rations) are not large enough to cancel the better image
7. A. Boltovskoy, Limnobios 1, 1 (1976).
IP : 132.248.29.219
8. J. D. Dodge and R. D. Saunders, Bot. Mar. 28, 99 (1985).
quality obtained. Also, LEI was the preferred detector
Fri, 11 Jan 2013
15:45:43
9. J.
D. Donde and S. Toriumi, Bot. Mar. 36, 145 (1993).
for these images because it is less susceptible to sample
10. A. Boltovskoy, Manual de Métodos Ficológicos, edited by K. Alveal,
charging. During our SEM observations radiation damM. E. Ferrario, E. C. Oliveira, and E. Sar, Universidad de Concepage was not a problem, although charging sometimes was
ción, Concepción, Chile (1995), pp. 119–138.
11. K. A. Steidinger, J. H. Landsberg, E. W. Truby, and B. A. Blakesley,
(Figs. 4(b)–(d)).
Descargar