COLUMNAS CENTRALES PROYECTISTA............................................... : ING. DAVID ADRIAN RUBIO RIVERA Hoja 1 de 1 _ 3 PROYECTO..................................................... : TANQUE SUPERFICIAL DE 3,000 m FECHA............................................................. : OCTUBRE DEL 2000 DATOS F'C DEL CONCRETO...................................... : 250.00 (Kg/cm2) 2 MOM. CENTRO "Y" POR C. ACC................ : 0.00 Fy DEL ACERO DE REFUERZO.................... : 4,200.00 (Kg/cm ) FACTOR DE ESBELTEZ (Kx)......................... : 1.00 Fy DE LOS ESTRIBOS.................................... : 4,200.00 (Kg/cm2) FACTOR DE ESBELTEZ (Ky)......................... : 1.00 LADO "X" DE LA COLUMNA........................... : 30.00 (cm) TRABE SUPERIOR IZQUIERDA "X"............... : 4.00 LADO "Y" DE LA COLUMNA........................... : 30.00 (cm) TRABE SUPERIOR DERECHA "X"................. : 4.00 LONG. LIBRE EN EL SENTIDO "X"................ : 405.00 (cm) TRABE INFERIOR IZQUIERDA "X"................ : 2.00 LONG. LIBRE EN EL SENTIDO "Y"................ : 405.00 (cm) TRABE INFERIOR DERECHA "X".................. : 2.00 (Kg-m) VARRILLA PRINCIPAL No.............................. : 5.00 COLUMNA SUPERIOR "X"............................. : 0.00 CARGA VIVA................................................... : 5,356.00 (Kg) COLUMNA DISEÑO "X".................................. : 1.00 CARGA MUERTA............................................ : 12,875.00 (Kg) COLUMNA INFERIOR "X"............................... : 0.00 CARGA ACCIDENTAL.................................... : 1,250.00 (Kg) TRABE SUPERIOR IZQUIERDA "Y"............... : 4.00 CORTANTE POR CARGA VERT.................... : 50.00 (Kg) TRABE SUPERIOR DERECHA "Y"................. : 4.00 CORTANTE POR CARGA ACCIDENTAL....... : 0.00 (Kg) TRABE INFERIOR IZQUIERDA "Y"................ : 2.00 RECUBRIMIENTO (4 cm MIN)........................ : 4.00 (cm) TRABE INFERIOR DERECHA "Y".................. : 2.00 MOM. SUPERIOR "X" POR C. VERT............ : 245.00 (Kg-m) COLUMNA SUPERIOR "Y"............................. : 0.00 MOM. INFERIOR "X" POR C. VERT............. : 185.00 (Kg-m) COLUMNA DISEÑO "Y".................................. : 1.00 "X" POR C. VERT.............. : 0.00 (Kg-m) COLUMNA INFERIOR "Y"............................... : 0.00 MOM. SUPERIOR "Y" POR C. VERT............ : 140.00 (Kg-m) As ACEREO PROPUESTO............................. : 8.00 (cm2) MOM. INFERIOR "Y" POR C. VERT............. : 0.00 (Kg-m) MODULO DE ELAST. CONCRETO................ : 237,170.80 (Kg/cm2) MOM. CENTRO "Y" POR C. VERT.............. : 0.00 (Kg-m) SUMA CARGAS TOTAL COLUMNAS............ : 315,000.00 (Kg) MOM. SUPERIOR "X" POR C. ACC.............. : 0.00 (Kg-m) NUM. DE COLUMNAS EN ESTE PISO.......... : 21.00 MOM. CENTRO MOM. INFERIOR "X" POR C. ACC............... : 0.00 (Kg-m) INTEMPERISMO S/N ?................................... : N MOM. CENTRO "X" POR C. ACC................ : 0.00 (Kg-m) CONTRAVENTEO EN "X" S/N?...................... : N MOM. SUPERIOR "Y" POR C. ACC.............. : 0.00 (Kg-m) CONTRAVENTEO EN "Y" S/N?...................... : N MOM. INFERIOR "Y" POR C. ACC............... : 0.00 (Kg-m) SISMO (M)ODERADO O (E)LEVADO............. : M RESULTADOS RELACIÓN ESF. ACT./PERM. : 0.39 LADO "X" DE LA COLUMNA (m)............. : 30.000 LADO "Y" DE LA COLUMNA (m)............. : 30.000 ACERO PRINCIPAL 4 VARRILLAS No. 5 REPARTIDAS EN LAS CUATRO CARAS ESTRIBOS No. 3 @ 13 cm HA = 0 cm HB = 57 cm ESTRIBOS No. 3 @ 25 cm HA = 67 cm HB = 338 cm ESTRIBOS No. 3 @ 13 cm HA = 338 cm HB = 405 cm FACTOR AMPLIACIÓN SENTIDO "X".... : 1.360 FACTOR AMPLIACIÓN SENTIDO "Y".... : 1.360 NOTA : EL PRIMER ESTRIBO SE COLOCARÁ A NO MÁS DE 6 cm LOS ESTRIBOS SE ESPACIARÁN A 13 cm EN EL TRASLAPE DE VARILLAS