T820 900A Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com Phase Control SCR 900 Amperes Average 1800 Volts T820 900A Phase Control SCR 900 Amperes Average, 1800 Volts Description: Powerex Silicon Controlled Rectifiers (SCR) are designed for phase control applications. These are all-diffused, Press-Pak, hermetic Pow-R-Disc devices employing the field proven amplifying gate. Features: Low On-State Voltage High di/dt Capability High dv/dt Capability Hermetic Packaging Excellent Surge and I2t Ratings T820 900A (Outline Drawing) Ordering Information: Select the complete 12 digit module part number from the table below. Example: T820169004DH is a 1600V 900A Phase Control SCR. Type T820 Applications: Power Supplies Motor Control Voltage VRRM (Volts) Current IT(av) (A) Turn-off Time tq (µsec) Gate Current IGT (mA) Lead Code 02 through 18 90 0 4 DH 200V through 1800V 900A 200 µsec (Typical) 150 mA 12” Revision Date: 04/20/2009 T820 900A Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com Phase Control SCR 900 Amperes Average 1800 Volts Absolute Maximum Ratings Characteristics Symbol Units Non-Repetitive Transient Peak Reverse Blocking Voltage VRSM VRRM + 100V Volts RMS On-State Current, TC = 70°C IT(RMS) 1410 Amperes Average Current 180° Sine Wave, TC = 70°C IT(AV) 900 Amperes RMS On-State Current, TC = 55°C IT(RMS) 1725 Amperes Average Current 180° Sine Wave, TC = 55°C IT(AV) 1100 Amperes Peak One Cycle Surge On-State Current (Non-Repetitive) 60 Hz ITSM 15,000 Amperes Peak One Cycle Surge On-State Current (Non-Repetitive) 50 Hz ITSM 13,700 Amperes Critical Rate-of-rise of On-State Current (Non-Repetitive) di/dt 400 A/μsec Critical Rate-of-rise of On-State Current (Repetitive) di/dt 150 A/μsec It 2 935,000 A sec Peak Gate Power Dissipation PGM 16 Watts Average Gate Power Dissipation PG(av) 3 Watts Operating Temperature TJ -40 to +125 °C Storage Temperature Tstg -40 to +150 °C 8 oz. 2 I t (for Fusing) for One Cycle, 60 Hz Approximate Weight Mounting Force 2 227 g 3000 to 3500 lb. 1360 to 1590 kg. Information presented is based upon manufacturers testing and projected capabilities. This information is subject to change without notice. The manufacturer makes no claim as to the suitability of use, reliability, capability, or future availability of this product. Revision Date: 04/20/2009 T820 900A Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com Phase Control SCR 900 Amperes Average 1800 Volts Electrical Characteristics, TJ=25°C unless otherwise specified Symbol Test Conditions Repetitive Peak Reverse Leakage Current Characteristics IRRM TJ=125°C, VR = VRRM Min. 60 mA Repetitive Peak Forward Leakage Current IDRM TJ=125°C, VD = VDRM 60 mA Peak On-State Voltage VTM IFM=1500A peak, 1.35 V Typ. Max. Units Duty Cycle < 0.1 % Threshold Voltage, Low-level Slope Resistance, Low-level V(TO)1 rT1 TJ = 125°C, I = 15%IT(AV) to πIT(AV) 0.78526 0.3505 V mΩ Threshold Voltage, High-level Slope Resistance, High-level V(TO)2 rT2 TJ = 125°C, I = πIT(AV) to ITSM 1.0789 0.2311 V mΩ TJ = 125°C, I = 15%IT(AV) to πIT(AV) VTM Coefficients, Low-level A= B= C= D= A= B= C= D= 5 VTM = A+ B Ln(I) +C(I) + D Sqrt(I) TJ = 125°C, I = πIT(AV) to ITSM VTM Coefficients, High-level VTM = A+ B Ln(I) +C(I) + D Sqrt(I) Typical Turn-On Time Typical Turn-Off Time Minimum Critical dv/dt – Exponential to VDRM ton IT = 1000A, VD = 600 V tq Tj = 125°C, IT = 250A, diR/dt = 50A/µs Reapplied dv/dt = 20 V/µs Linear to 80% VDRM dv/dt TJ = 125°C 0.68865 -0.04011 -1.578 E-05 0.025339 2.6289 -0.37766 8.873 E-05 0.034055 µs 200 µs 300 V/µs Gate Trigger Current IGT TJ = 25°C, VD = 12 V 150 mA Gate Trigger Voltage VGT TJ = 25°C, VD = 12 V 3.0 V Non-Triggering Gate Voltage VGDM TJ = 125°C, VD = VDRM 0.15 V Peak Forward Gate Current IGTM 4 A Peak Reverse Gate Voltage VGRM 5 V Maximum Thermal Resistance, Double Sided Cooling Max. Units Junction-to-Case Case-to-Sink 0.037 0.020 °C/W °C/W Thermal Characteristics RΘ(J-C) RΘ(C-S) Revision Date: 04/20/2009 T820 900A Phase Control SCR 900 Amperes Average 1800 Volts Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com Maximum On-State Forward Voltage Drop Maximum Transient Thermal Impedance (Junction to Case) ( Tj = 125 °C ) 0.04 Thermal Impedance - Rjc - °C/W On-State Voltage - Vtm - Volts 5 4 3 2 1 0.035 0.03 0.025 0.02 0.015 0.01 0.005 0 10 100 1000 10000 0 0.0001 100000 0.001 0.01 0.1 Instantaneous On-State Current - Itm - Amperes (Sinusoidal Waveform) (Sinusoidal Waveform) 1600 130 1400 180° Max. Case Temperature - Tcase - °C Maximum Power Dissipation Per SCR - Watts 10 Maximum Allowable Case Temperature Maximum On-State Power Dissipation 120° 1200 90° 60° 1000 30° 15° 800 600 400 200 120 110 100 90 80 30° 15° 60° 90° 120° 70 180° 60 0 50 0 200 400 600 800 1000 0 100 200 300 400 500 600 700 800 Average On-State Current - It(av) - Amperes Average On-State Current - It(av) - Amperes Maximum On-State Power Dissipation Maximum Allowable Case Temperature (Rectangular Waveform) 900 1000 (Rectangular Waveform) 2000 130 360° 1800 270° 1600 120 Max. Case Temperature - Tcase - °C Maximum Power Dissipation Per SCR - Watts 1 Time - t - Seconds 180° 1400 120° 90° 1200 60° 1000 30° 15° 800 600 400 110 100 90 80 70 15° 30° 60° 60 90° 120° 180° 270° 50 200 0 360°C 40 0 200 400 600 800 1000 1200 Average On-State Current - It(av) - Amperes 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Average On-State Current - It(av) - Amperes Revision Date: 04/20/2009