Tearing T este r SLY-S1 INSTRUCTION MANUAL for Tearing Tester SLY-S1 Labthink 1 Tearing T este r SLY-S1 Notice The information contained in this manual is derived from proprietary data from Labthink. This manual has been prepared expressly for the purpose of assisting operation and maintenance personnel in their use and general maintenance of SLY-S1 Tearing Tester. Publication of this information does not imply any rights to reproduce or use it for purposes other than installing, operating, or maintaining the instrument described herein. These provisions are intended to state all of the rights and responsibilities between Labthink and the customer. They take place of and supersede all warranties, expressed or implied, and whether of merchantability, fitness or otherwise. The remedies contained in this instruction manual are exclusive. 2 Tearing T este r SLY-S1 Contents Preface 1. Introduction Principles Features Specifications Explanations Unpacking 2. Instrument Instrument Appearance Control Panel Installation 3. Software System Requirement Installation Run the Software Delete the Software How to Use the Software 4. Operation Overview Operation Procedure Change Test Range Adjust the Cutter and Specimen Holder Comparison of Test Results 5. Maintenance General Maintenance Calibration Diagnostic and Troubleshooting 3 Tearing T este r SLY-S1 Technical Support Appendix: Change Test Range Customer Service Regulation 4 Tearing T este r SLY-S1 Preface About This Guide Welcome to the Labthink PARAM® SLY-S1 Tearing Tester system. This manual contains a description of the operation and maintenance of your Tearing Tester. In addition, it provides step-by-step instructions for the installation and application of the SLY-S1 software. Safety Precautions Observe the following safety precautions when you operate or perform service on the SLY-S1 Tearing Tester: Power supply must be AC 220V 50Hz/60Hz, and should be grounded. The instrument should be powered off and unplugged before troubleshooting or maintenance. The instrument SHOULD NOT be operated with other high-power electrical appliances. This instrument SHOULD NOT be operated in high humidity, intensely corrosive, combustible, explosive, or similar environment, or under intensive vibration or strong electromagnetic interference. Perform operation only according to this instruction manual. Operation Notice Extreme care should be taken to avoid personal injuries by the cutter. Make sure the compressed air is clean and without any visible fluid drop or solid substances which may cause damage to the instrument Balance the instrument before test. Label the test side and direction of the specimen. Overloading operation is prohibited. Select a proper pendulum weight. Level the instrument carefully and keep away from vents before test. 5 Tearing T este r SLY-S1 1. Introduction SLY-S1 Tearing Tester is designed for the tearing test of films, sheets, flexible PVC, PVDC, waterproof films, woven materials, polypropylene, polyester, paper, cardboard, textiles and nonwovens. Standards This instrument conforms to various national and international standards: ISO 6383-1-1983, ISO 6383-2-1983, ISO 1974, ASTM D1922, ASTM D1424, ASTM D689, TAPPI T414, GB/T 16578.2-2009, GB/T 455 Principles Lift the pendulum up to a certain height to give it an initial potential energy. The pendulum tears the specimen while swinging down. Computer calculates the decreased energy caused by tearing to obtain the required force for tearing. Features The instrument is controlled by computer with automatic and electronic measurement which is convenient for the operation Pneumatic specimen clamping and automatic release of pendulum could avoid the system error effectively Computer assisted horizontal adjustment system could maintain the instrument optimum status Equipped with pendulums of multiple capacities Professional software supports multi-unit data output Equipped with RS232 port which is convenient to the data transmission and external connection Support Lystem™ Lab Data Sharing System for uniform and systematic data management 6 Tearing T este r SLY-S1 Specifications Item Specification Pendulum Capacity 200gf, 400gf, 800gf, 1600gf, 3200gf, 6400gf Pressure of Gas Supply 0.6 MPa (outside of supply scope) Port Size Φ4 mm PU Tubing Instrument Dimension 480 mm (L) x 380 mm (W) x 560 mm (H) Power Supply AC 220V 50/60Hz Net Weight 23.5 kg (Basic Pendulum of 200gf) Explanations The pendulum weight equals the weight of basic pendulum plus that of extra weight; With the 200gf basic pendulum, test range can be extended to 800 gf by installing extra weight; With the 1600gf basic pendulum, test range can be extended to 6400 gf by installing extra weight. Unpacking Remove the instrument from the shipping carton and inspect for any signs of damage. Contact the delivery agent immediately if any damage observed. Leave the instrument in the shipping carton for the delivery agent to examine the damage. If there is no visible damage, check the contents of your shipment against the packing slip. Notify Labthink immediately if there are any discrepancies. The instrument is shipped in a special designed box to prevent any damage. If re-shipment is necessary, the instrument should be repacked in the original box. Please save the box properly. 7 Tearing T este r SLY-S1 2. Instrument Instrument Appearance Figure 1 Instrument structures 1. Adjusting Rod 2. Fastening Nuts 3. Spirit level 4. Base Plate 5. Frame; 6. Pendulum 7. Extra Weight 8. Extra weight (Small) 9. Balance Weight 10. M8 Bolt 11. Bearing 12. Gas Tube 13. Cutter 14. Stationary & Moveable Clamps 15. Spring 16. Cutter handle 17. Pendulum Latch Adjusting rod Fastening nuts Pendulum Extra weight For leveling the instrument To fasten the adjusting rod when leveled up A basic pendulum together with extra weights to provide tearing force To extend test range of pendulum 8 Tearing T este r SLY-S1 Extra weight (Small) Balance Weight Specimen Holder Cutter Pendulum Latch To form the 200 gf or 1600 gf basic pendulum To balance the pendulum (DO NOT disassemble) Air-operated specimen clamp with a stationary part and a movable part on the pendulum To precut a slit of 20±0.5 mm on the specimen To hold or release the pendulum Control Panel Figure 2 Control Panel Function keys “CLAMP” “TEST” Press this key to clamp the specimen; press again to release Press this key to release the pendulum Installation The system should be placed with enough space to allow installation and operation. The instrument should not be operated under strong electromagnetic interferences. 9 Tearing T este r SLY-S1 The instrument should not be operated with other high-power electrical appliances The power supply should be 220V 50/60Hz, and well grounded. Operating personnel should perform the test according to this instruction manual. Place the instrument on a steady table with at least 0.5 m surrounding for installation. Connect the power cord and communication cable as shown in Figure 3. Figure 3 Rear view of the instrument 1. COM Port 2. Joint for Gas Tube 3. Power Switch 4. Fuse Holder 5. Power Connector Before connecting the gas supply, please remove the Φ4 PU tubing (100mm) in the joint for gas tube (2 in Figure 3). Connect the gas supply to the joint for gas tube (2 in Figure 3) with a Φ4 PU tube. To level the instrument, first turn the fastening nuts (2 in Figure 1) to release the adjusting rod. Tune the legs to center the spirit level (3 in Figure 1) on the base. Fasten the nuts again. Turn on the instrument and gas supply. Open the operating software and click “Calibration”. Referring to Figure 4, unscrew the M6 bolt, remove the cap, and install the pendulum to the bearing. The latches will automatically catch the pendulum. Lift the pendulum and hold it with the pendulum latch. The displayed value in the following dialog box should be “180.0”. Screw 10 Tearing T este r SLY-S1 the M6 bolt back to secure the pendulum. Figure 4 Install the pendulum 1. Cap 2. M6 Bolt 3. Bearing 4. Pendulum 5. Positioning Pin 11 Tearing T este r SLY-S1 For first time use, lift the pendulum and the pendulum latch automatically holds it. Press “CLAMP” key but do not mount the specimen for now. Press “TEST” key to release the pendulum and let it stop naturally. Repeat this process at least 15 times before performing tests. Note: “CLAMP” key must be pressed every time before the test; otherwise, pendulum will not be released. To balance the pendulum, first lift it. The displayed value on the software should be “180.0”. Click “Balance” tab: Release the pendulum and observe the red and blue bars. Tune the adjusting rod until no red or blue bars are present in the above dialog box when the pendulum stops. Do the bare swing for two more times to check the balance of the pendulum prior to fasten the adjusting rod. When performing the bare swing, the tearing force in the “Calibration” tab should be 0.0%. 12 Tearing T este r SLY-S1 3. Software System Requirement Hardware requirement CPU: 2.4 GHz or higher RAM: 128 MB and above Hard disk: 40 G or larger CD-ROM: required Display: 1024X768, 75 Hz refresh rate At least one RS232 port Operating system Windows 98 or above Note: If operation encounters any problem, exit the software and restart it. Installation 1. Start Windows, and close other programs. 2. Insert the software CD of SLY-S1 into your CD-ROM. 3. Browse the contents of the CD in “My computer” and find the “SLY-S1” folder. 4. 5. Under the “SLY-S1” folder, double click “Setup” icon to start the installation. Select the installation language and click OK to continue. 13 Tearing T este r SLY-S1 Note: you can exit the installation process by clicking “Cancel” in any step. 6. Click “Next”. 14 Tearing T este r SLY-S1 7. Read the terms in license agreements and select “I accept the terms in the license agreement”. Click “Next” to continue. 8. Input “User Name” and “Company Name”, and choose the account authorization for this application. Then click “Next”. 15 Tearing T este r SLY-S1 9. You can choose “Complete” or “Custom” installation and click “Next” to continue setup, 10. If you choose “Custom” setup, select the program features you want to install Select the installation path and click “Next”. 16 Tearing T este r SLY-S1 11. Click “Install” to start installation. 12. Click “Finish” to finish installation. The system will automatically create a shortcut on your desktop 17 Tearing T este r SLY-S1 Run the Software The software automatically creates a desktop shortcut as “SLY-S1” when the installation completes. Double click this icon to start the program, or choose “Start” --“Program”-“Labthink”--“SLY-S1”--“Launch SLY-S1” to start. Delete the Software You can delete the software by choosing “Start” --“Program”-- “Labthink”--“SLY-S1”--“Uninstall SLY-S1”. Select “Yes” to confirm deleting the software. How to Use the Software Double click the program icon to open the software. 18 Tearing T este r SLY-S1 Four major sections are shown in the main interface: 1. Tool Bar: functions including Open, Save, Reset, Clamp, and Exit, etc. 2. Plot Area: system automatically plots the test curve during the test. 3. Current Value: displays the angle, force, and time during the test; 4. Statistical Results: including Maximum Value, Minimum Value, Average Value, Deviation, and Standard Deviation (S_D); There are three tabs on the right side: Test (current view), Unit, and Sheet. Click “Unit” tab to view the results in different units: 19 Tearing T este r SLY-S1 Click “Sheet” tab to view all test results in list; 20 Tearing T este r SLY-S1 Click “Preset” in “Edit” menu to view preset information: In this dialog box, you can set up the specimen information, displayed units, test range, and buzzer option. Click “Save” to confirm settings when finished. 21 Tearing T este r SLY-S1 Click “Calibration” in “System” menu: Lift the pendulum with left hand and the pendulum would be stopped and supported by the latch automatically and the swing angle would be displayed as “180.0”. Click “Balance” to enter the following interface. 22 Tearing T este r SLY-S1 Perform a blank test (without specimen) and observe whether blue or red grids are displayed in the above interface when the pendulum stops. Unfasten the 4 fastening nuts with hand and turn the adjusting rod in clockwise or counterclockwise direction until there is no blue or red grid when the pendulum stops. Then tighten the fastening nuts again. 23 Tearing T este r SLY-S1 4. Operation Overview Prepare test specimens Turn on the instrument and warm up for 90 min Connect the gas supply Level and balance the instrument Set up parameters Install a proper weight Mount test specimen Start test Finish test Operation Procedures Prepare Test Specimen According to ISO 291 standard, all test specimens should be conditioned at 23±2℃ and 50±5% RH for 12 hours. Two types of specimens can be tested: constant-radius and rectangular. Cut Slit Cut Slit 24 Tearing T este r SLY-S1 According to specific requirements, prepare a number of test specimens as shown in the above scheme. Make sure the test direction and side are notified in the report. Take three measurements along the tearing direction and average these values to obtain specimen thickness. Please note: there is no linear correlation between tearing force and specimen thickness. However, when compare different specimens, the thicknesses should be unified for easy comparison. Prepare the Instrument Turn on the instrument, warm up for at least 90 min, and adjust the output pressure to 0.5—0.55 MPa. Level and balance the instrument as described in Installation section of 2 Instrument. Open the operating software and enter “Preset” interface. Set up the corresponding parameters and click “Save” to confirm. Start the Test Set the pendulum to its latched position. Place the test specimen in specimen holder with the right tearing direction. Press “CLAMP” to grip the specimen. Then cut a slit of 20±0.5 mm with the cutter. Press “TEST” key to release the pendulum. As the specimen is torn up, check if the tearing force lies in between 20%—80% of the pendulum. If not, change the extra weight until the pendulum weight is proper. If the number of specimen layers is changed, modify the parameter “Layers” in “Preset” interface. If the pendulum weight is changed, modify the parameter “Configuration” in “Preset” interface, and rebalance the instrument. If a test is performed improperly, click “Undo” to cancel results of such test. When all tests are finished, save test results and print out test report. 25 Tearing T este r SLY-S1 Change Test Range The test range can be easily changed from 200 gf to 6400 gf by installing different extra weights. Appendix 1 gives several quick means for test range modification. Generally: With the 200 gf basic pendulum, test range can be extended to 800 gf by installing extra weight; With the 1600 gf basic pendulum, test range can be extended to 6400 gf by installing extra weight. Take the change from 200 gf to 400 gf for example: a. Set the pendulum to its latched position and hold it with the pendulum latch; b. Hold the 200 gf balance weight, unscrew the M4X15 bolt, and remove the extra weight; c. Install the 400 gf extra weight by screwing the M4X15 bolt; d. Balance the instrument; e. Perform a bare swing without specimen mounting, and input the maximum angle reached into the red box of “Calibration” interface. Adjust the Cutter and Specimen Holder Replace and Adjust the Cutter If the precut slit of the specimen by the cutter exceeds 20±0.5 mm, the position of cutter should be adjusted. First unscrew two M4X8 bolts as shown in Figure 5, place a calibration ruler at the bottom of the specimen holder, slightly move the cutter to contact the meter tightly, and re-screw the M4X8 bolts. Once the blade of cutter is blunt, it should be replaced simply by unscrewing the M4X8 bolts. 26 Tearing T este r SLY-S1 Left View Front View Figure 5 Adjust the cutter 1&6. Cutter 2. Upper Surface of Stationary Clamp 3. M4X8 Bolts 4. Cutter Head 5. Calibration Ruler Adjust the Specimen Holder If the distance between stationary and movable clamps exceeds 2.8±0.3 mm, it should be adjusted. At test mode, set the pendulum to its latched position. As shown in Figure 6, remove the protective hood for encoder (3), unscrew M5X8 bolt, and place the calibration ruler head of the calibration ruler in between the stationary and movable clamps. Adjust the angle to “180.0” prior to re-screw the M5X8 bolt and reinstall the protective hood for encoder. 27 Tearing T este r SLY-S1 Left View Top View Figure 6 Adjust the clamps 1. Pendulum 2. M5X8 Bolt 3. Protective Hood for Encoder 4. Movable Clamp 5. Frame 6. Calibration Ruler Head 7. Calibration Ruler 8. Stationary Clamp 9. Cylinder 28 Tearing T este r SLY-S1 Comparison of Test Results For the same type of specimen, test results along the same tearing direction should agree. If not, check the following possible reasons: Ambient conditions (temperature and relative humidity) are different; Different thickness; Different precut slit; Different tearing direction; Different number of specimen layers Improper pendulum weight’ Instrument is not leveled and balanced; Instrument is not calibrated; Working table is not stable. 29 Tearing T este r SLY-S1 5. Maintenance General Maintenance 1. 2. 3. 4. 5. Read the instruction manual thoroughly before any operation. Power supply must be AC 220V 50/60Hz, and should be grounded. DO no operate with other high-power electrical appliances. Do not disassemble the instrument without authorization. Power off the instrument and cover with a sheet after test. Special Notice: Perform operation only according to this instruction manual. Operating personnel should be present during the test. Perform at least 15 times of bare swing prior to test. Extreme care should be taken to avoid personal injuries by the cutter. Balance the instrument before test. Label the test side and direction of the specimen. Overloading operation is prohibited. Select a proper pendulum weight. Level the instrument carefully and keep away from vents before test. DO NOT uninstall the balance weight. Calibration Employ the 50% calibration weight to perform calibration. 1. Level and balance the instrument; 2. Set the pendulum to its latched position; 3. Change the force unit to “%”; 4. Press “TEST” key to release the pendulum and observe if the tearing force is 0.0%; 5. Reset the pendulum; 6. Install the corresponding 50% calibration weight to the bearing as shown in Figure 7; 30 Tearing T este r SLY-S1 Figure 7 Install the calibration weight 1. Pendulum 2. Movable Clamp 3. Calibration Weight 4. Shaft 7. Place the shaft with the calibration weight to the movable clamp and press “CLAMP” key; 8. Press “TEST” key to release the pendulum. The displayed value should be 50.0%±0.2%; 9. If not, contact Labthink for instrument adjustment. Note: here, 50% calibration weight means that the calibration weight is 50% of the pendulum weight. Diagnostics and Troubleshooting 1. Specimen holder and pendulum latch do not work. Check gas supply and connection tube. 31 Tearing T este r SLY-S1 2. No response after instrument powered on. Check power supply, fuse, and electrical circuit. 3. Communication failure. Check communication cable and connection 4. Do not print. Check communication cable, power supply, and indicator light of the printer. Technical Support Web support Please visit our website for more details of general problems and technical supports. http://www.labthinkinternational.com.cn Contact us You can also contact us by telephone or e-mail: Tel: +86-531 -85063398 E-mail: afterservice@labthink.cn Notice: Before you call us for help, please make sure: Read the Instruction Manual thoroughly and check all possible problems; Place instrument and Instruction Manual at hand; Prepare the following information: model, purchase date and manufacturing code. 32 Tearing T este r SLY-S1 Appendix: Change Test Range Please refer to the diagrams below for the proper arrangement of the extra weights for the appropriate pendulum and test range. Using 200gf basic pendulum. 200gf. The whole components added to pendulum are 200gf basic pendulum, M4×15 screw, lock washer, and 200gf weight. 400gf or 800gf. The whole components added to pendulum are 200gf basic pendulum, M4×15 screw, lock washer, 200gf weight, and 400gf weight or 800gf weight. 33 Tearing T este r SLY-S1 Using the 1600gf basic pendulum. 1600gf. The whole components added to pendulum are 1600gf basic pendulum, M6×20 screw, retaining pin, and 1600gf weight. 3200gf. The whole components added to pendulum are 1600gf basic pendulum, M6×20 screw, retaining pin, 1600gf weight, and 3200gf weight. 6400gf. The whole components added to pendulum are 1600gf basic pendulum, M6×50 screw, retaining pin, 1600gf weight, and 6400gf weight. 34 Tearing T este r SLY-S1 Customer Service Regulation General Provisions ※ Purpose: This regulation is instituted to satisfy the need of customers with professional and timely service. ※ Content: This regulation includes items of general provisions, service instructions and response time. ※ Service Aim: Provide customers with professional, timely and continuous service. Try our best to satisfy the requirements of customers. ※ Service Principle: Integrity and sense of responsibility, sophisticated skill and customer oriented. ※ Performance Pledge: 1. Notice of lack of configuration should be provided in written form within thirty days from AWB date. Otherwise, it is considered as a conform information. Responses will be made within one workday after receiving written notification. 2. Products are warranted with free service and replace components of the same brand, type and specifications for a period of one year from the AWB data against defects of quality. 3. Replaced parts are warranted with free service of replacement or maintenance for a period of 90 days from the date of purchase against defects of quality. 4. Technical whole-life service will be provided outside warranty period. While cost of maintenance is free, cost of material as well as freight out and home is charged. 5. Repaired instruments are warranted with free service of replacement or maintenance for a period of 180 days from the return date of the repaired instrument against defects of quality. 6. Responses will be made within one hour after receiving service application. Disposing suggestions and solution program will be provided within one working day. ※ Contact information (8:00-17:00 Monday to Friday Peking time): Tel: +86-531-85068566 Service Tel: +86-531-85063398 Fax: +86-531-85812140 E-mail: trade.en@labthink.cn Http://www.labthinkinternational.com.cn Zip Code: 250031 Address: No.144 Wuyingshan Road Jinan China 35 Tearing T este r SLY-S1 ※ Exclusion: For products not sold by LABTHINK directly, the sales regulation abides by the service agreement and quality guarantee regulations between distributors and customers. Division of authority and responsibility as well as the quality guarantee regulations between corresponding distributor and LABTHINK follow the content of contract (oral agreement) between these two sides. Service instructions ※ Instructions for Initial Use 1. Open-package Inspection: Check the required configuration of product in contract with that of packing list. Make sure that all the parts mentioned in the packing list are included. (When taking out the products from its package, pay attention to the caution sign such as “Do not hold here”.) Be sure all seals on the instrument are intact. Otherwise please contact LABTHINK as soon as possible. 2. Product Commissioning: Please review the instruction manual and other materials supplied with the instruments carefully. Test the instruments under specified environment, parameters and operating mode. If there is any problem about our products, please don't hesitate to clarify it with LABTHINK before commissioning. (Software of instrument computer has been installed before delivery. Users can use the computer directly. Discs supplied with instrument should be kept carefully for later use) ※ Confirmation of Warranty Period Warranty period is supported from AWB date (Buyer and seller as well as the product mode are given clear indication). Without such supporting document, the warranty start date will be Ex-factory Date of the purchased products recorded by LABTHINK. In any of the following cases, there will be no maintenance free of charge. 1. Products are not purchased from LABTHINK or LABTHINK’s agents and distributors are not covered in the service regulation. 2. Defects of instrument or other components caused by the use of accessories or peripheral equipments not produced or authorized by LABTHINK. 3. Defects or damages of instruments or other components resulted from abnormal reasons (including unsatisfied power supply, working environment, not the first delivery, long term storage, outside force and foreign body entering instrument). 4. Defects or damages of instruments or other components caused by natural influences (such as earthquake or fire) or accidents (such as stealing and lost) 36 Tearing T este r SLY-S1 5. Defects or damages of instruments or other components caused by dismantling, repair, and refit without LABTHINK permission. 6. Defects or damages of instruments or other components caused by plugging and connecting power cord , typing cord, communication cord and other connecting wire without cutting the power supply. 7. According to the international convention, correlation insurance company is directly responsible for charges of maintenance or complete damage resulting from serious damage during international transportation. Customers must inform LABTHINK within one working day after receiving the product. (For uninsured cargo, it is recommended that customers take out insurance) ※ Expiration of Warranty Period Warranty period is expired in one year from the AWB date (indicating the transaction sides and instrument type). Without above supporting document, the warranty start date will be the Ex-factory Date of the purchased instrument recorded by LABTHINK. ※ Charge of Service 1. Training a. LABTHINK provides customers with demonstration video of the sold products free of charge (attached with instrument or transmitted through Internet) b. On the premise that customers need and are willing to bear correlative expenses, LABTHINK engineer may arrive at the nominated places for product installation, debugging, training and commission. While maintenance service is free of charge, Users must undertake relating travel expense of the engineer (including round-trip air ticket, ticket, accommodation and other travel expense). With the signed (or reached) service contract (oral agreement) between two sides and prepaid relating expenditures, LABTHINK will send its engineer for contract service. 2. Maintenance a. For problem caused by product quality within warranty period, LABTHINK will provide product maintenance, technical support, freight out and home as well as cost of replaced components free of charge. b. Problem not caused by product quality within warranty period or maintenance outside warranty period is only charged for replaced components. However, freights home and out is at the customer’ side (only the replaced component is charged if transportation of instrument is not needed). c. Door-to-door service outside warranty period requires signed (or reached) service contract (oral agreement) between two sides. Users must undertake relating travel expense of the 37 Tearing T este r SLY-S1 engineer (including round-trip air ticket, ticket, accommodation and other travel expense). With the signed (or reached) service contract (oral agreement) between two sides and prepaid relating expenditures, LABTHINK will send its engineer for contract service. Service Content 1. Please contact LABTHINK as soon as possible if there is problem during the process of operation. To help service man providing accurate and timely solution for your problem or trouble, be sure to make the following preparation before contact: (1)Check product type on product certification (or in instruction manual and manufacturer certificate); (2)Having reviewed instruction manual carefully and having it at hand at the time of contact (3)Make sure the protective tube and all the connecting wire are in good condition when there is malfunction. (4)Collect information about symptoms of problem (including displaying content and operation condition), problem time and other detailed information (customers who conceal actual information should be responsible for the lost) 2. LABTHINK will make telephone call or door-to-door return visit about using condition of product periodically. Response Time 1. LABTHINK’s personnel will response to help users solving the problem within one hour after receiving telephone call or written notice. It will give customers technical support through remote technologies such as telephone call, E-mail, and demonstration video. If component replacement is needed, the required component will be sent out within one working day (if there is charged fees, the required component will be sent out after receiving fax of transferred account). 2. If instruments need to be sent back for maintenance, LABTHINK will notify the user within one working day after receiving the product about the inspection information. Instruments will be repaired within two working days and send out within one working day after repairing (if there is charged fees, the product will be sent out after receiving fax of transferred account). 3. If technical support cannot be realized through remote technology while it is inconvenient to send instruments back, LABTHINK can offer field service. Charges and regulations are as above stated. Unless there are special circumstances, the response time is: 38 Tearing T este r SLY-S1 Notify customers the personal information of LABTHINK engineer within one workday after receiving customer notice and reaching agreement. On the premise that customers provide corresponding invitation and other necessary help, LABTHINK will get the engineer’s visa as soon as possible. LABTHINK engineer reach the conferred place within one week of the visa date. Others This regulation is the only open service regulations for customers. Herein other ones with special purpose or beyond the above items are refused. The right to explain this regulation is reserved by LABTHINK INSTRUMENTS CO., LTD. The right to revise this regulation is reserved by LABTHINK INSTRUMENTS CO., LTD. Distributors (agents) should refer to cooperation agreement additionally. 39 Tearing T este r SLY-S1 LABTHINK INSTRUMENTS CO., LTD. 144 Wuyingshan Road, Jinan 250031 China Website: http://www.labthikinternational.com.cn Tel: +86-531-85068566 Service Tel: +86-531-85063398 Fax: +86-531-85812140 40