TÉCNICO SUPERIOR UNIVERSITARIO EN INGENERIA CIVIL ASIGNATURA: INTEGRADORA I. ACTIVIDAD: INSTALACION ELECTRICA ALUMNO: ANGEL YAHIR FERNANDEZ MARTINEZ JORGE ANTONIO HERNANDEZ GERARDO VALDIVIA HERNANDES OSMAR MANUEL ACOSTA GRADO: 3° GRUPO “C” DOCENTE: M.C. PAOLA YAZMIN HENRY IBARRA HUEJUTLA DE REYES, HGO. 16 JUNIO DEL 2021 CALCULO DE ALUMBRADO PLANTA BAJA Cochera: A= largo(m): ancho(m): + = 5.8 4.5 26.1 1.2 27.3 2730.00 700 largo(m): ancho(m): = 5.8 3.5 20.3 20.3*100 = 2030.00 700 = 2030.00 lums largo(m): ancho(m): = + = 5 2 10 11.4 21.4 21.4*100 = 2140.00 lums 2140.00 700 largo(m): ancho(m): = 1.2 2.5 3 3*100 = 300.00 700 = 300.00 lums largo(m): ancho(m): = 3.2 3 9.6 9.6*300 = 2880.00 700 = 2880.00 lums largo(m): ancho(m): = 0.5 2 1 1*100 = 100.00 700 = 100.00 lums largo(m): ancho(m): = 7 2 14 14*300 = 4200.00 700 = 4200.00 lums 27.3 * 100 = = 2730.00 lums 3.90 = 4 luminarias Estancia: A= 2.90 = 3 luminarias Comedor: A= = 3.06 = 3 luminarias Medio baño: A= 0.43 = 1 luminaria Cocina: A= 4.11 = 5 luminarias Escalera: A= 0.14 = 1 luminaria Area de lavado: A= 6 = 6 luminarias PLANTA ALTA Rec. Principal: A= largo(m): ancho(m): = 3.8 4.5 17.1 17.1*300 = 5130 800 = 5130 lums largo(m): ancho(m): = 3.2 4.5 14.4 14.4*100 = 1440 700 = largo(m): ancho(m): = 3.4 4.2 14.28 14.28*300 = 4284 800 = largo(m): ancho(m): = 3.6 4.2 15.12 15.12*300 = 4536 800 = 4536 lums largo(m): ancho(m): = 2.5 2 5 5*100 = 500 700 = 500 lums largo(m): ancho(m): = 2.5 2 5 5*100 = 500 700 = largo(m): ancho(m): = 0.5 2 1 1*100 = 100 700 = 6.4125 = 7 luminarias Baño 2: A= 1440 lums 2.05714 = 2 luminarias Rec. Jr1: A= 4284 lums 5.355 = 6 luminarias Rec. Jr2: A= 5.67 = 6 luminarias Baño 3: A= 0.71429 = 1 luminaria Pasillo: A= 500 lums 0.71429 = 1 luminaria Escalera: A= 100 lums 0.14286 = 1 luminaria PLANTA DE AZOTEA Area de lavado: A= largo(m): ancho(m): = 2 3 6 6*300 = 1800 700 = 1800 lums 2.57143 = 3 luminarias CALCULO DE CONDUCTORES ELECTRICOS CONTACTO: 180 W PLANTA BAJA APAGADOR: 100 W Gasto total del circuito en planta baja: Cochera 100 180 X X 4 3 = = = 400 W 540 W 940 W 5720 W Total del circuito en amperes: Estancia 100 180 X X 3 5 = 300 W = 900 W = 1200 W 100 180 X X 3 3 = = = 300 W 540 W 840 W 100 W 180 W 280 W Comedor Medio baño 100 180 X X 1 1 = = = 100 180 X X 5 5 = 500 W = 900 W = 1400 W 100 X 1 = = 100 W 100 W Area de lavado 100 180 X X 6 2 = = = 600 W 360 W 960 W Cocina Escalera A A = = W V 5720 127 W V = 45.039 A CONTACTO: 180 W APAGADOR: 100 W PLANTA ALTA Rec. Principal 100 180 X X 7 6 = 700 W = 1080 W = 1780 W Gasto total del circuito en planta alta: 5640 W Baño 2 100 180 Recamara jr1 100 180 Recamara jr2 100 180 X X X X 2 3 6 4 = = = 200 W 540 W 740 W = 600 W = 720 W = 1320 W X X 6 4 = 600 W = 720 W = 1320 W 100 180 X X 1 1 = = = 100 W 180 W 280 W 100 X 1 = = 100 W 100 W Total del circuito en amperes: A W V = 5640 127 A = W V = 44.409 A Baño 3 Gasto total del circuito en planta de azotea: Pasillo 660 W Total del circuito en amperes: Escalera 100 X 1 = = 100 W 100 W A = W V PLANTA DE AZOTEA Area de lavado 100 180 A = X X 3 2 = = = 300 W 360 W 660 W 660 127 W V = 5.1969 A EQUILIBRIO DE FASES DE CIRCUITO circuito 1 (planta baja) circuito 2 (planta baja) cochera escaleras comedor area de lavado ∑ 940 100 840 960 2840 W W W W W estancia cocina medio baño 1200 1400 280 ∑ 2880 A = W V A = W V A = 2840 W = 22.362 A 127 V A = 2880 W 127 V 22.362 = 30 A = 10 AWG/THW 19 mm. 22.677 = circuito 3 (planta alta) 30 A ∑ = 10 AWG/THW 19 mm. 1780 740 280 100 2900 W W W W W recamara jr1 recamara jr2 pasillo 1320 1320 100 ∑ 2740 A = W V A = W V A = 2900 W = 22.835 A 127 V A = 2740 W 127 V 30 A = 22.677 A circuito 4 (planta alta) rec. Principal baño 2 baño 3 escalera 22.835 = W W W W = 10 AWG/THW 19 mm. 21.575 = 30 A W W W W = 21.575 A = 10 AWG/THW 19 mm. circuito 5 (planta de azotea) area de lavado ∑ A = W V A = 660 W 127 V 5.1969 = 15 A = 5.1969 A = 14 AWG/THW 19 mm. 660 W 660 W DIAGRAMA UNIFILAR 127 V C-1 C-2 C-3 C-4 C-5 1X30A 1X30A 1X30A 1X30A 1X15A 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 180 W 100 W 100 W 100 W 100 W 180 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W 180 W 100 W 100 W 100 W 180 W 100 W 100 W 100 W 180 W 180 W 100 W 100 W 180 W 180 W 100 W 100 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 180 W 2,900 W 2,740 W 180 W 180 W 2,840 W 2,880 W 660 W CUADRO DE CARGA UBICACIÓN PLANTA BAJA PLANTA ALTA PLANTA DE AZOTEA CIRCUITO LUMINARIA 100 W LUMINARIA DE PARED 100 W CONTACTO 180 W CARGA TOTAL W A=W/127 EFICIENCIA 70% INTERRUPTOR ELECTROMAGNETICO AMPERES TIPO DE CABLE AWG AISLANTE RHW A DIAMETRO DE DUCTO DIAMETRO DE CANALIZACION C-1 4 10 8 2840 2840 22.36 19.90 30 A 10, 12 AWG 19 MM. 13 MM. C-2 4 5 11 2880 2880 22.67 20.18 30 A 10, 12 AWG 19 MM. 13 MM. C-3 5 6 10 2900 2900 22.83 20.32 30 A 10, 12 AWG 19 MM. 13 MM. C-4 13 0 8 2740 2740 21.57 19.20 30 A 10, 12 AWG 19 MM. 13 MM. C-5 1 2 2 660 5.19 4.62 15 A 12, 14 AWG 19 MM. 13 MM. GASTO TOTAL: 12020 FASES B C 660 5720 5640 660